製品名
Titriplex® III solution, for metal titration c(Na-EDTA 2 HO) = 0.1 mol/l, Titripur®, reag. Ph. Eur.
agency
reag. Ph. Eur.
product line
Titripur®
form
liquid
quality
Analyzed in our ISO 17025 accredited QC lab
reaction suitability
reaction type: Complexometric reactions
packaging
Titripac® of
concentration
0.1 M
technique(s)
titration: suitable
pH
7.5 (20 °C in H2O)
density
1.02 g/cm3 at 20 °C
storage temp.
15-25°C
Quality Level
Analysis Note
Form liquid
Amount-of-substance concentration 0.0995 - 0.1005 mol/L
Measurement uncertainty ± 0.0003 mol/L
Traceability NIST SRM
The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 682 Zinc) by means of volumetric standard Zinc (article number 1.02409), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.
Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.
Amount-of-substance concentration 0.0995 - 0.1005 mol/L
Measurement uncertainty ± 0.0003 mol/L
Traceability NIST SRM
The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 682 Zinc) by means of volumetric standard Zinc (article number 1.02409), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.
Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.
Features and Benefits
Accreditation:
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.
Packaging
SKU-pack size numbers ending with a “3” are SmartChemicals with an RFID tag on the label for seamless data transfer to the instrument, e.g. xxxxxx1003 or xxxxxxx 4003. More information on www.sigmaaldrich.com/SmartChemicals
Titripac® packaging - all SKU-pack size numbers ending “4000, 4003, 9010, 9013” - more information on www.sigmaaldrich.com/Titripac
Titripac® packaging - all SKU-pack size numbers ending “4000, 4003, 9010, 9013” - more information on www.sigmaaldrich.com/Titripac
Legal Information
Titripac is a registered trademark of Merck KGaA, Darmstadt, Germany
Titriplex is a registered trademark of Merck KGaA, Darmstadt, Germany
Titripur is a registered trademark of Merck KGaA, Darmstadt, Germany
Application
The Titriplex® III solution can be used for:
- Determining the concentrations of heavy metals in environmental samples. It is employed for titrations in the determination of metals such as arsenic, lead, mercury, copper, manganese, zinc, and iron.
- Metal ion chelation to ascertain the concentrations of Cu(II) and Zn(II) in colorimetric titrations, and in buffer preparation to maintain pH stability during biochemical assays.
保管分類
12 - Non Combustible Liquids
wgk
WGK 1
flash_point_f
Not applicable
flash_point_c
Not applicable
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
関連コンテンツ
Karl Fischer titration determines water content in raw materials and products, a widely used analytical method.
カールフィッシャー滴定法は、原材料や製品中の水分量を測定する分析方法で、広く使用されている分析法です。
グローバルトレードアイテム番号
| カタログ番号 | GTIN |
|---|---|
| 1.08431.9010 | 04022536104591 |
| 1.08431.1000 | 04022536104560 |
| 1.08431.1003 | 04054839633249 |
| 1.08431.4000 | 04027269029708 |
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)