Millipore Sigma Vibrant Logo
Attention: We have moved. Merck Millipore products are no longer available for purchase on MerckMillipore.com.Learn More

KGEPG3TTT1 Opticap® XLT 30 Millipore Express® SHF Gamma Compatible 0.2 µm 1-1/2 in. TC

KGEPG3TTT1
1  Double Easy-Open bag
Purchase on Sigma-Aldrich

Overview

Replacement Information
Description
Catalogue NumberKGEPG3TTT1
Trade Name
  • Millipore Express®
DescriptionOpticap® XLT 30 Millipore Express® SHF Gamma Compatible 0.2 µm 1-1/2 in. TC
References
Product Information
Device ConfigurationCapsule
Connections, Inlet/Outlet38 mm (1-1/2 in.) Sanitary Flange
Connections, Vent/Drain1/4 in. Hose Barb with double O-ring seal
Housing MaterialPolypropylene (PP)
Maximum Differential Pressure, bar (psid)Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
Maximum Inlet Pressure, bar (psi)6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
T-line/Gauge PortT-line
Quality LevelMQ400
Applications
Biological Information
Bacterial EndotoxinsAqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
MediaMillipore Express® SHF
SterilityNon-sterile, Gamma compatible
SterilizationGamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
WettabilityHydrophilic
Physicochemical Information
Pore Size0.2 µm
Inlet ConnectionSanitary Flange
Outlet ConnectionSanitary Flange
Air Diffusion at 23 °C≤98.2 mL/min @ 2.8 bar (40 psig) in water
Bubble Point at 23 °C≥4000 mbar (58 psig) air with water
Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Maximum Inlet Pressure (psig)80 psig
Maximum Differential Pressure80 psi (5.5 bar) continuous
100 psi (6.9 bar) intermittent
Maximum Inlet Temperature25 °C
Non-Fiber ReleasingThis product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
TOC/ConductivityAfter sterilization and a controlled water flush of 33 L, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 µS/cm per USP <645> at 25 °C.
USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Dimensions
Cartridge Nominal Length30 in. (75 cm)
Length87.1 cm (34.3 in.)
Diameter10.7 cm (4.2 in.)
Filtration Area1.71 m²
Inlet to Outlet Width15.2 cm (6.0 in.)
Device Size30 in.
Inlet Connection Diameter1-1/2 in.
Outlet Connection Diameter1-1/2 in.
Materials Information
Chemistry
  • Polyethersulfone (PES)
Device Material
  • Gamma stable polypropylene/Polysulfone
Seal MaterialSilicone (SI)
Support MaterialPolyester
Vent Cap MaterialPolypropylene (PP)
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Storage and Shipping Information
Packaging Information
Material Size1
Material PackageDouble Easy-Open bag
Transport Information
Supplemental Information
Specifications
Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥4.5 L
Global Trade Item Number
Catalogue Number GTIN
KGEPG3TTT1 04053252492297

Documentation

Material Qualification Dossier

TitleVersion
1.0

Quality Management Dossier (Open Access)

Title

Operational Excellence Dossier

Title

Certificates of Quality

Title
Opticap XLT 30 Capsule Millipore Express SHF Membrane C7PA85876
Opticap XLT 30 Capsule Millipore Express SHF Membrane C8AA06697
Opticap XLT 30 Capsule Millipore Express SHF Membrane C8BA34365
Opticap XLT 30 Capsule Millipore Express SHF Membrane - C0EB49613
Opticap XLT 30 Capsule Millipore Express SHF Membrane - C8SA66373
Opticap XLT 30 Capsule Millipore Express SHF Membrane C3CB87578
Opticap XLT 30 Capsule Millipore Express SHF Membrane C3KB51128
Opticap XLT 30 Capsule Millipore Express SHF MembraneC8KA93981

Technical Info

Title
Autoclaving Guidelines for Opticap® XL and XLT Disposable Capsule Filters
Scalable Process Filtration with Millipore Express® SHF 0.2 μm Filters
Scalable Process Filtration with Opticap® XL 150, 300 and 600 Capsules with Millipore Express® Membranes

User Guides

Title
Opticap® XL Capsules and Opticap® XLT Capsules