Millipore Sigma Vibrant Logo
Attention: We have moved. Merck Millipore products are no longer available for purchase on MerckMillipore.com.Learn More

115696 高效能薄層層析矽膠玻璃片,含螢光指示劑

View Products on Sigmaaldrich.com
115696
Purchase on Sigma-Aldrich

Overview

Replacement Information
Replacement InformationIn North America 1.15696.0001 replaces and is identical to 15696-6

Products

Catalogue NumberPackaging Qty/Pack
1.15696.0001 纖維紙箱 25 units
Description
Catalogue Number115696
Replaces15696-6; 15696
DescriptionHPTLC Silica gel 60 F₂₅₄s
OverviewHPTLC plates deliver fast and quantitative analysis of complex samples for manual or automated use. Our HPTLC silica plates work three times faster than conventional TLC plates – and they are more sensitive. The particle sizes range in HPTLC is between 4-8 µm, which creates a smoother surface and a higher separation power than TLC plates.
References
Product Information
HS Code3822 19 90
Quality LevelMQ100
Applications
ApplicationGlass HPTLC Silica gel 60 F₂₅₄s plates. Silica gel HPTLC plates size 20 x 10 cm, 25 sheets.
Biological Information
Physicochemical Information
Dimensions
Materials Information
Toxicological Information
Safety Information according to GHS
Storage class10 - 13 Other liquids and solids
Safety Information
Product Usage Statements
Storage and Shipping Information
StorageStore at +2°C to +30°C.
Packaging Information
Transport Information
Supplemental Information
Specifications
Specific surface area (according to BET; 5-Pt. measurement)480 - 540 m²/g
Pore volume (N₂-isotherm)0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution)5 - 7 µm
Layer thickness150 - 200 µm
Deviation of layer thickness per plate≤ 35 µm
Chromatographic testings:
A) Colour test
hRf-values
- bleu vif organol, colour test, lipophile

17 - 22
- Ceres Black G, colour test, lipophile38 - 43
- ceres Violet brn, colour test, lipophile58 - 64
separation number
- colourtest, lipophile

≥ 10.0
B) Steriod test
hRf-values
- hydrocortisone, steroid test

23 - 29
- Reichstein S, steroid test36 - 45
- methyltestosterone, steroid test43 - 52
separation number
- steroid test

≥ 10.5
Typical value determined on a conditioned plate
Eluent A) Toluene (45% rel.humidity)
Eluent B) Ethyl acetate/Toluene (95+5 v/v; 20% rel.humidity)
Global Trade Item Number
Catalogue Number GTIN
1.15696.0001 04022536161495

Documentation

高效能薄層層析矽膠玻璃片,含螢光指示劑 MSDS

Title

Safety Data Sheet (SDS) 

高效能薄層層析矽膠玻璃片,含螢光指示劑 Certificates of Analysis

Product Number PackagingSpecificationLot Number
1.15696.0001 纖維紙箱PDF Specification Document

Brochure

Title
Fast and Precise. Thin Layer Chromatography by.

Technical Info

Title
365 - Detection of Compounds in amelanchir ovalis extract
371 - Detection of Stevioside and Rebaudioside in Stevia extract
413 - Determination of Stevioside and Rebaudioside A in beverages and sweetner using TLC-MS
Separation of UV-Filter