Millipore Sigma Vibrant Logo

613424 Tocopherol Set - Calbiochem

Overview

Replacement Information

Pricing & Availability

Catalogue Number AvailabilityPackaging Qty/Pack Price Quantity
613424-1SET
Retrieving availability...
Limited Availability
Limited Availability
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

      Glass bottle 1 set
      Retrieving price...
      Price could not be retrieved
      Minimum Quantity is a multiple of
      Maximum Quantity is
      Upon Order Completion More Information
      You Saved ()
       
      Request Pricing
      Description
      OverviewContains one 50 mg vial each of all-rac-α-tocopherol, all-rac-β-tocopherol, RRR-γ-tocopherol, and RRR-δ-tocopherol.
      Catalogue Number613424
      Brand Family Calbiochem®
      References
      ReferencesBrigelius-Flohe, R., et al. 1999. FASEB J. 13, 1145.
      Emmert, D.H., et al. 1999. Arch. Fam. Med. 8, 537.
      Theriault, A., et al. 1999. Clin. Biochem. 32, 309.
      Stone, W.L., et al. 1997. J. Natl. Cancer Inst. 89, 1006.
      van Poppel, G., et al. 1997. Cancer Lett. 114, 195.
      Product Information
      FormLiquid
      Quality LevelMQ100
      Applications
      Biological Information
      Purity≥95% by HPLC (for each component)
      Physicochemical Information
      Dimensions
      Materials Information
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Ship Code Ambient Temperature Only
      Toxicity Standard Handling
      Storage +2°C to +8°C
      Do not freeze Ok to freeze
      Special InstructionsNote: most vials contain 50 mg tocopherol ± 10%, although some may contain more. If the material is to be used as a quantitative standard, it is recommended that the material be weighed analytically before use. If small quantities of tocopherol are to be used at one time, slowly draw the material from the vial using a Hamilton syringe, flush with inert gas, and re-seal the vial. If the entire vial is to be used at once, use the following procedure to determine the exact amount of material in each vial:

      1. Measure the weight of the vial with tocopherol.
      2. Use an organic solvent (e.g. Ethanol) to make a solution of the entire contents of the vial.
      3. Dry the vial and measure the weight of the dry vial. **Note: the solvent must be completely evaporated from the sample before use.**
      4. Calculate the mass of the tocopherol that was in the original solution based on the following information:
      all-rac-α-tocopherol, C₂₉H₅₀O₂, MW 430.7
      all-rac-β-tocopherol, C₂₈H₄₈O₂, MW 416.7
      RRR-γ-tocopherol, C₂₈H₄₈O₂, MW 416.7
      RRR-δ-tocopherol, C₂₇H₄₆O₂, MW 402.7
      Packaging Information
      Packaged under inert gas Packaged under inert gas
      Transport Information
      Supplemental Information
      Specifications
      Global Trade Item Number
      Catalogue Number GTIN
      613424-1SET 04061838432292

      Documentation

      Tocopherol Set - Calbiochem MSDS

      Title

      Safety Data Sheet (SDS) 

      Tocopherol Set - Calbiochem Certificates of Analysis

      TitleLot Number
      613424

      References

      Reference overview
      Brigelius-Flohe, R., et al. 1999. FASEB J. 13, 1145.
      Emmert, D.H., et al. 1999. Arch. Fam. Med. 8, 537.
      Theriault, A., et al. 1999. Clin. Biochem. 32, 309.
      Stone, W.L., et al. 1997. J. Natl. Cancer Inst. 89, 1006.
      van Poppel, G., et al. 1997. Cancer Lett. 114, 195.
      Data Sheet

      Note that this data sheet is not lot-specific and is representative of the current specifications for this product. Please consult the vial label and the certificate of analysis for information on specific lots. Also note that shipping conditions may differ from storage conditions.

      Revision11-June-2008 JSW
      DescriptionA convenient four-vial pack containing ~50 mg each of all-rac-α, all-rac-β, RRR-γ, and RRR-δ-tocopherols for use as reference standards for the quantitative and qualitative determination of tocopherols in biological samples. The term vitamin E covers several related tocopherols (all-rac-α-, all-rac-β-, RRR-γ-, RRR-δ-tocopherols) and tocotrienols that have been isolated from natural sources. Of these compounds, α-tocopherol is reported to have the highest biological activity. Most studies in human subjects rely on all-rac-α-tocopherol concentrations in plasma or serum to assess vitamin E status. The biological activity of vitamin E has generally been associated with its well-defined antioxidant property, specifically against lipid peroxidation in biological membranes. With the emergence of a better understanding of the antioxidant effect of vitamin E, researchers have shown it to possess several potentially anti-tumor and cardioprotective properties, including antagonizing the oxidation of low-density lipoproteins, inhibiting platelet aggregation and adhesion, preventing smooth muscle proliferation, and preserving normal coronary dilation. More recently, the observation that all-rac-αtocopherol has a signaling function in vascular smooth muscle cells has raised interest in the roles of vitamin E beyond its antioxidative function. The RRR-γ-tocopherol has been shown to act as a nucleophile that can trap electrophilic mutagens in lipophilic compartments.
      FormLiquid
      Intert gas (Yes/No) Packaged under inert gas
      Purity≥95% by HPLC (for each component)
      SolubilityEthanol
      Storage +2°C to +8°C
      Do Not Freeze Ok to freeze
      Special InstructionsNote: most vials contain 50 mg tocopherol ± 10%, although some may contain more. If the material is to be used as a quantitative standard, it is recommended that the material be weighed analytically before use. If small quantities of tocopherol are to be used at one time, slowly draw the material from the vial using a Hamilton syringe, flush with inert gas, and re-seal the vial. If the entire vial is to be used at once, use the following procedure to determine the exact amount of material in each vial:

      1. Measure the weight of the vial with tocopherol.
      2. Use an organic solvent (e.g. Ethanol) to make a solution of the entire contents of the vial.
      3. Dry the vial and measure the weight of the dry vial. **Note: the solvent must be completely evaporated from the sample before use.**
      4. Calculate the mass of the tocopherol that was in the original solution based on the following information:
      all-rac-α-tocopherol, C₂₉H₅₀O₂, MW 430.7
      all-rac-β-tocopherol, C₂₈H₄₈O₂, MW 416.7
      RRR-γ-tocopherol, C₂₈H₄₈O₂, MW 416.7
      RRR-δ-tocopherol, C₂₇H₄₆O₂, MW 402.7
      Toxicity Standard Handling
      Merck USA index14, 9495
      ReferencesBrigelius-Flohe, R., et al. 1999. FASEB J. 13, 1145.
      Emmert, D.H., et al. 1999. Arch. Fam. Med. 8, 537.
      Theriault, A., et al. 1999. Clin. Biochem. 32, 309.
      Stone, W.L., et al. 1997. J. Natl. Cancer Inst. 89, 1006.
      van Poppel, G., et al. 1997. Cancer Lett. 114, 195.