Millipore Sigma Vibrant Logo

KVPVA3TTT1 Opticap XLT30 Viresolve NFP 1-1/2 in. TC/TC

View Products on Sigmaaldrich.com
KVPVA3TTT1
1  Double Easy-Open bag
Price could not be retrieved
Minimum Quantity is a multiple of
Maximum Quantity is
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Limited Availability
Limited Availability
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

       

      Contact Customer Service

      Overview

      Description
      Catalogue NumberKVPVA3TTT1
      Trade Name
      • Viresolve®
      DescriptionOpticap XLT30 Viresolve NFP 1-1/2 in. TC/TC
      Product Information
      Device ConfigurationCapsule
      Connections, Inlet/Outlet38 mm (1-1/2 in.) Sanitary Flange
      Connections, Vent/Drain1/4 in. Hose Barb with double O-ring Seal
      Maximum Differential Pressure, bar (psid)Forward: 5.5 bar (80 psid). Reverse: 3.4 bar (50 psid)
      Maximum Inlet Pressure, bar (psi)5.5 bar (80 psi) @ 23 °C
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      T-line/Gauge PortT-line
      Quality LevelMQ400
      Applications
      ApplicationParvovirus removal
      Key Applications
      • Protein Purification
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaViresolve® NFP
      SterilizationWater wet filter for 5 min @ 3.4 bar (50 psi); liquid cycle, slow exhaust @ 123 °C maximum 60 min
      Physicochemical Information
      Inlet ConnectionSanitary Flange
      Outlet ConnectionSanitary Flange
      Air Diffusion at 23 °C≤30 mL/min @ 3.45 bar (50 psig) in water
      Maximum Inlet Pressure (psig)80 psig
      Maximum Inlet Temperature25 °C
      Non-Fiber ReleasingThis product was manufactured with a Viresolve® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      TOC/ConductivityAfter sterilization and a controlled water flush of 36 L, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 µS/cm per USP <645> at 25 °C.
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Length86.4 cm (34 in.)
      Filtration Area1.26 m²
      Inlet to Outlet Width15.2 cm (6.0 in.)
      Process Volume750 L
      Device Size30 in.
      Inlet Connection Diameter1-1/2 in.
      Outlet Connection Diameter1-1/2 in.
      Materials Information
      Chemistry
      • Modified Polyvinylidene Fluoride (Modified PVDF)
      Device Material
      • Polypropylene
      Seal MaterialSilicone (SI)
      Support MaterialPolypropylene
      Vent Cap MaterialPolypropylene (PP)
      Vent O-ring MaterialSilicone (SI)
      Vent/Drain1/4 in. hose barb with double O-ring seal
      Packaging Information
      Material Size1
      Material PackageDouble Easy-Open bag
      Global Trade Item Number
      Catalogue Number GTIN
      KVPVA3TTT1 04053252606274