Millipore Sigma Vibrant Logo

NAC-USI100/51 NovAseptic Connector, According to ASME, Tube Standard ASTM A270 (inch)

NAC-USI100/51
1  All open ends on the NovAseptic Connector are protected with plastic covers on delivery. The NovAseptic Connector is pre-assembled and packaged in a closed box.
Retrieving price...
Price could not be retrieved
Minimum Quantity is a multiple of
Maximum Quantity is
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Limited Availability
Limited Availability
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

       

      Contact Customer Service

      Overview

      Replacement Information
      Description
      Catalogue NumberNAC-USI100/51
      Trade Name
      • NovaSeptic
      DescriptionNovAseptic Connector, According to ASME, Tube Standard ASTM A270 (inch)
      References
      Product Information
      Surface Finish, WettedManually polished; Ra ≤1.6 μm (63 μin)
      Operating Temperature Range-80 to 200 °C
      Quality LevelSP2
      Applications
      Application NotesThe applied gasket (not included) may have different design temperature and/or pressure limits than the NovAseptic Connector. The weakest component in the assembled product determines the maximum design temperature and pressure limits.
      Biological Information
      Physicochemical Information
      Operating Pressure Range-1 to –7 bar
      Dimensions
      DimensionsFor information about the dimensions of this product please refer to the Product Specification Sheet.
      Weight1.7 kg (3.75 lb.)
      Materials Information
      Device Material
      • Welding Flange and Locking Ring: Stainless Steel 316L (ASME SA-479)
      • Bolt and Nut: Stainless Steel A193 Gr B8M/A194 Gr B8M
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Regulatory ConformanceThe NovAseptic Connector does comply for USA with the relevant requirements in ASME. The equipment has been calculated and evaluated of stress levels due to internal pressure in accordance with ASME VIII, Division 2, "Mandatory design based on stress analysis". The analysis has been calculated with assistance of FEM.
      Storage and Shipping Information
      Packaging Information
      Material Size1
      Material PackageAll open ends on the NovAseptic Connector are protected with plastic covers on delivery. The NovAseptic Connector is pre-assembled and packaged in a closed box.
      Transport Information
      Supplemental Information
      Specifications
      Connector TypeFlush mounted
      Global Trade Item Number
      Catalogue Number GTIN
      NAC-USI100/51 04053252608957