Our broad portfolio consists of multiplex panels that allow you to choose, within the panel, analytes that best meet your needs. On a separate tab you can choose the premixed cytokine format or a single plex kit.
Cell Signaling Kits & MAPmates™
Choose fixed kits that allow you to explore entire pathways or processes. Or design your own kits by choosing single plex MAPmates™, following the provided guidelines.
The following MAPmates™ should not be plexed together:
-MAPmates™ that require a different assay buffer
-Phospho-specific and total MAPmate™ pairs, e.g. total GSK3β and GSK3β (Ser 9)
-PanTyr and site-specific MAPmates™, e.g. Phospho-EGF Receptor and phospho-STAT1 (Tyr701)
-More than 1 phospho-MAPmate™ for a single target (Akt, STAT3)
-GAPDH and β-Tubulin cannot be plexed with kits or MAPmates™ containing panTyr
.
Catalogue Number
Ordering Description
Qty/Pack
List
This item has been added to favorites.
Select A Species, Panel Type, Kit or Sample Type
To begin designing your MILLIPLEX® MAP kit select a species, a panel type or kit of interest.
Custom Premix Selecting "Custom Premix" option means that all of the beads you have chosen will be premixed in manufacturing before the kit is sent to you.
Catalogue Number
Ordering Description
Qty/Pack
List
This item has been added to favorites.
Species
Panel Type
Selected Kit
Qty
Catalogue Number
Ordering Description
Qty/Pack
List Price
96-Well Plate
Qty
Catalogue Number
Ordering Description
Qty/Pack
List Price
Add Additional Reagents (Buffer and Detection Kit is required for use with MAPmates)
Qty
Catalogue Number
Ordering Description
Qty/Pack
List Price
48-602MAG
Buffer Detection Kit for Magnetic Beads
1 Kit
Space Saver Option Customers purchasing multiple kits may choose to save storage space by eliminating the kit packaging and receiving their multiplex assay components in plastic bags for more compact storage.
This item has been added to favorites.
The Product Has Been Added To Your Cart
You can now customize another kit, choose a premixed kit, check out or close the ordering tool.
Attention: We have moved. Merck Millipore products are no longer available for purchase on MerckMillipore.com.Learn More
Water is a main component of the dissolution testing procedure. The most important use of water is the preparation of the dissolution media, but it is also used for washing and rinsing the vessels, as well as in the thermostatic bath. In addition, water is usually needed for the analysis of the dissolution samples (to prepare the blanks for UV/Visible spectrometry, to prepare the mobile phases in HPLC, etc.).
The purity of the water used in preparing the dissolution media is important since it is in direct contact with the drug product being tested. Impurities in the dissolution media may interfere with the drug itself or with some of the components of the dosage form, and therefore modify the experimental outcome. In addition, the water used for the final rinse of the vessels and all the components coming in contact with the drug during the test (paddle, basket, etc.) should be of the same purity as the water used to prepare the dissolution media.
The following water contaminants may have an effect on dissolution testing:
Organics Organic molecules may interact with the drug or with some of the components of the dosage form, and have an effect on the dissolution. They may also interfere with the analytical method used to analyze the samples.
Ions Water hardness (calcium and magnesium ions) may form deposits on the vessels. Ions may also have an effect on the pH or on the ionic strength of the dissolution medium. This is especially important in the cases where water is used as the dissolution medium. In addition, ions, in particular metallic ions, may interact with the drug or with some of the components of the dosage form, and alter their physicochemical properties.
Bacteria Bacteria may form biofilms and release ions and organic molecules, which may in turn interfere with the test.
Particles Particles may participate to the release of the active ingredient from the dosage form, and may interfere with the analysis of the samples.
Dissolved Gas The level of dissolved gas, in particular dissolved oxygen, in the dissolution medium has an impact on the dissolution of some drug products. Deaeration of the dissolution media is often recommended.
It is important to note that the sensitivity of the analytical method used to analyze the dissolution method can also influence the choice of water quality used to prepare the dissolution medium. Direct methods of analysis, such as UV/Visible spectroscopy, are usually less sensitive to water quality than separation-based methods such as HPLC or CE. Very sensitive detection methods, providing superior selectivity, are increasingly being used, especially in dissolution testing of complex formulations, such as extended-release formulations. If these very sensitive detection methods, such as mass spectrometry (e.g. in LC-MS), fluorescence or luminescence are used, high quality water should be used to prepare the dissolution media, as these methods are very susceptible to water contaminants.