Millipore Sigma Vibrant Logo
Attention: We have moved. Merck Millipore products are no longer available for purchase on MerckMillipore.com.Learn More

MFSL06GH3 Non-sterilized Millipak® Final Fill 60 Filter Unit 5.0  µm 1/4  in. HB/HB

MFSL06GH3
3  Double Easy-Open bag
Purchase on Sigma-Aldrich

Přehled

Replacement Information
Description
Catalogue NumberMFSL06GH3
Trade Name
  • Millipak®
DescriptionNon-sterilized Millipak® Final Fill 60 Filter Unit 5.0  µm 1/4  in. HB/HB
References
Product Information
HS Code8421 29 90
Device ConfigurationCapsule
Connections, Inlet/Outlet6  mm (¼  in.) stepped hose barb inlet and outlet
Maximum Differential Pressure, bar (psid)Foward:80 psi (5.5 bar) at 25 °C (0.1 µm, 0.22 µm, 0.45 µm, hydrophobic 0.22 µm); Reverse: 10 psi (0.7 bar) at 25 °C
Maximum Inlet Pressure, bar (psi)80 psi (5.5 bar) at 25 °C
Good Manufacturing PracticesThese products are manufactured in a facility which is certified to ISO® 9001:2015 Quality Management Systems.
Quality LevelMQ400
Applications
Biological Information
Bacterial EndotoxinsAqueous extraction contains < 0.25 EU/mL per device as determined using the Limulus Amebocyte Lysate (LAL) test, meeting requirements of USP <85>, EP 2.6.14 and JP 4.01.
MediaDurapore®
Sterilitynon-sterilized
SterilizationDevice integrity and retention was maintained after 3 autoclave cycles of 90 minutes at 126  °C. Devices can withstand a dose ≤ 40  kGy gamma exposure.
WettabilityHydrophilic
Physicochemical Information
Pore Size5.0 µm
Inlet ConnectionStepped Hose Barb
Outlet ConnectionStepped Hose Barb
Bubble Point at 23 °C≥ 2.0   psi (138 mbar) air with water
Flow Rate4.5 L/min @ 0.69  bar ∆P
Non-Fiber ReleasingThis product was manufactured with a Durapore® membrane which meets the criteria for a “non-fiber releasing” filter as defined in 21 CFR 210.3 (b)(6), validated based on large volume parenteral specifications as detailed in USP <788> Particulate Matter in Injections
USP Bacterial EndotoxinsAqueous extraction contains < 0.25 EU/mL per device as determined using the Limulus Amebocyte Lysate (LAL) test, meeting requirements of USP <85>, EP 2.6.14 and JP 4.01.
Dimensions
Filtration Area300 cm²
Process Volume60 L
Inlet Connection Diameter1/4 in.
Outlet Connection Diameter1/4 in.
Materials Information
Chemistry
  • Polyvinylidene Fluoride (PVDF)
Device Material
  • Polysulfone
Support MaterialPolysulfone
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Storage and Shipping Information
Packaging Information
Material Size3
Material PackageDouble Easy-Open bag
Transport Information
Supplemental Information
Specifications
Global Trade Item Number
Katalogové číslo GTIN
MFSL06GH3 04054839378409

Documentation

Material Qualification Dossier

TitleVersion
1.0

Operational Excellence Dossier

Title

Certificates of Quality

Title
Millipak Final Fill Capsule Durapore Membrane C0HB68834
Millipak Final Fill Capsule Durapore Membrane C2EB66424
Millipak Final Fill Capsule Durapore Membrane C4HB35148

Technical Info

Title
Improved Product Recovery using Blow-down and Millipak®Final Fill Filters
Integrity Test Troubleshooting - Beyond Rewet and Retest
Reduce Contamination Risks and Simplify Filtration System Design and Operation

Data Sheet

Title
Durapore® Family Guide

User Guides

Title
Wetting Instructions for Filter Units with Durapore Membrane

Související produkty a aplikace

Product Families