Millipore Sigma Vibrant Logo
Attention: We have moved. Merck Millipore products are no longer available for purchase on MerckMillipore.com.Learn More
 
 

Chromolith® RP-18 Endcapped HPLC Columns


Fast Separation at Lower Flow Rates

Chromolith® RP-18 endcapped

Chromolith Performance RP-18 endcapped HPLC columns are designed for rapid separations of more complex mixtures. The Chromolith® 3 mm internal-diameter column (length 100 mm) is an ideal alternative to conventional particulate columns with internal diameters of 4.6, 4 or 3 mm. Even difficult separations, which often take 15 to 30 minutes on particulate columns, typically take only 5 to 10 minutes on Chromolith® 3 mm i.d. 

Column Coupling

Chromolith® 3 mm i.d. columns can be easily coupled using the column coupler to form columns of 20 cm or longer as required. As shown in Tables 1 and 2, this results in very high peak resolution at moderate pressure with flow rates between 1 and 1.5 mL/min.

Chromolith® Performance RP-18e 100-3 mm

Column Chromolith® Performance RP-18e 100-3 mm
Mobile Phase Acetonitrile / buffer pH 1.8 (gradient)
Flow rate 2.0 mL/min
Pressure 92 bar
Detection UV 254 nm
Temp. 30°C
Injection volume 1 μL
Sample 1. - 2. By-products
3. Levothyroxine
4. - 9. By-products>
Chromolith® Performance RP-18e 100-3 mm
Two coupled Chromolith® Performance RP-18e 100-3 mm

Column Two coupled Chromolith® Performance RP-18 endcapped 100-3 mm
Mobile Phase Acetonitrile / buffer pH 1.8 (gradient)
Flow rate 1.5 mL/min
Pressure 140 bar
Detection UV 254 nm
Temp. 30°C
Injection volume 1 μL
Sample 1. - 2. By-products
3. Levothyroxine
4. - 9. By-products
Two coupled Chromolith® Performance RP-18 endcapped 100-3 mm

Excellent Column Efficiency and Peak Resolution

Table 3 depicts a typical fast separation of four compounds in less than two minutes using a Chromolith® 4.6 mm i.d. column at a flow rate of 4 mL/min. The second example (Table 4) shows the same separation on a Chromolith® 3 mm i.d. column. Both chromatograms exhibit excellent column efficiency and peak resolution, however the 3 mm i.d. column demonstrates improved sensitivity at just 1.7 mL/min, thus saving 57% of solvents.

Chromolith® Performance RP-18e 100-4.6 mm

Column Chromolith® Performance RP-18 endcapped 100-4.6 mm
Mobile Phase Acetonitrile / water 40/60
Flow Rate 4.0 mL/min
Pressure 137 bar
Detection UV 254 nm
Temp. Ambient
Injection Volume 1 μL
Sample

1. Biphenyl-4.4 ’ -ol
2. Biphenyl-2.2 ’ -ol
3. Biphenyl-4-ol
4. Biphenyl-2-ol

Chromolith® Performance RP-18 endcapped 100-4.6 mm
Chromolith® Performance RP-18e 100-3 mm

Column Chromolith® Performance RP-18e 100-3 mm
Mobile Phase Acetonitrile / water 40/60
Flow Rate 1.7 mL/min
Pressure 100 bar
Detection UV 254 nm
2.4 μL flow cell * 
Temp. Ambient
Injection Volume 1 μL *
Sample 1. Biphenyl-4.4 ' -ol
2. Biphenyl-2.2 ' -ol
3. Biphenyl-4-ol
4. Biphenyl-2-ol
Chromolith® Performance RP-18e 100-3 mm

* For optimum results with 3 mm i.d. columns, extra-column volume must be small.

Chromolith® RP-18 Endcapped 2 mm and 3mm Columns

Product
Internal Diameter
Ordering Number
Chromolith® Performance RP-18 endcapped 100 x 2 mm
100 x 3 mm
152006
152001
Chromolith® Flash RP-18 endcapped 25 x 2 mm
25 x 3 mm
152014
152003
Chromolith® FastGradient RP-18 endcapped 50 x 2 mm
50 x 3 mm
152007
152002
 
HPLC Application Collections

HPLC Application Collections

Application Notes and Methods

Learn More
Chromatography Application World

Chromatography
Application World

The ultimate source for the latest news in your field

Learn More