Description
Catalogue NumberKWLSA02HH3
ReplacesKWSSL4HB3
Trade Name
  • Opticap®
DescriptionOpticap® XL2 Milligard® Low Protein Binding 0.5/0.2 µm 9/16 in. HB/HB
References
Product Information
FormatDouble Layer
Device ConfigurationCapsule
Connections, Inlet/Outlet14 mm (9/16 in.) Hose Barb
Filter GradeLow Protein Binding Milligard® Media
Housing MaterialPolypropylene (PP)
Maximum Differential Pressure, bar (psid)3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
European Pressure Equipment DirectiveEMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Quality LevelMQ400
Applications
Biological Information
Bacterial EndotoxinsAqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
MediaMilligard® LPB
Sterilization3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
Physicochemical Information
Pore Size0.5 / 0.2 µm
Inlet ConnectionHose Barb
Outlet ConnectionHose Barb
Gravimetric ExtractablesThe extractables level was equal to or less than 50 mg per capsule after a 1 L flush and 24 hours in water at controlled room temperature.
Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Maximum Inlet Pressure (psig)80 psig
Maximum Inlet Temperature25 °C
Non-Fiber ReleasingThis product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Dimensions
Cartridge Nominal Length2 in. (5 cm)
Length14.2 cm (5.6 in.)
Diameter12.5 cm (4.9 in.)
Filtration Area0.07 m²
Inlet to Outlet Width14.2 cm (5.6 in.)
Device Size2 in.
Inlet Connection Diameter9/16 in.
Nominal Pore Size0.5 / 0.2 µm
Outlet Connection Diameter9/16 in.
Materials Information
Chemistry
  • Low Protein-Binding Mixed Cellulose Esters (MCE)
Device Material
  • Polypropylene
Seal MaterialSilicone (SI)
Support MaterialPolyester
Vent Cap MaterialPolypropylene (PP)
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Storage and Shipping Information
Packaging Information
Material Size3
Material PackageDouble Easy-Open bag
Transport Information
Supplemental Information
Specifications
Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
Global Trade Item Number
Numer katalogowy GTIN
KWLSA02HH3 04053252343780

Documentation

Opticap® XL2 Milligard® Low Protein Binding 0.5/0.2 µm 9/16 in. HB/HB MSDS

Title

Safety Data Sheet (SDS) 

Certificates of Quality

Title
Opticap XL 2 Capsule Milligard LPB Media C0SB83068
Opticap XL 2 Capsule Milligard LPB Media C8DA46098
Opticap XL 2 Capsule Milligard LPB Media C9DA17663