Analytes AvailableSpecies ReactivityKey ApplicationsDetection Methods
AFP ANGPTL3 ANGPTL4 ANGPTL6/AGF FABP1 FGF-19 FGF-21 FGF-23 HGF HMplexLuminex xMAP
Description
Catalogue NumberHLPPMAG-57K
Trade Name
  • MILLIPLEX
DescriptionMILLIPLEX MAP Human Liver Protein Magnetic Bead Panel - Metabolism Multiplex Assay
OverviewMillipore’s MILLIPLEX MAP Human Liver Protein Panel is a 9-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma and tissue/cell culture samples: AFP, ANGPTL3, ANGPTL4, ANGPTL6/AGF, FABP1/L-FABP, FGF-19, FGF-21, FGF-23 and HGF.
NOTE: When assaying ANGPTL6/AGF it is recommended that serum samples be used.
Background InformationLiver-secreted proteins play important roles in metabolic regulation. For example, liver-secreted proteins have been shown to regulate circulating lipoprotein levels, energy expenditure, glucose metabolism, and fatty acid uptake. In addition, some liver-secreted proteins may also serve as biomarkers for liver diseases and gastric cancer. Accurate measurement of liver proteins is critical to obtain understanding of their biological functions.
References
Product Information
Detection methodLuminex xMAP
ConfigurationDesign your multiplex kit by choosing available analytes within this panel.
Precision, %
  • AFP: Intra-assay <10% CV Inter-assay <20%
  • ANGPTL3: Intra-assay <10% CV Inter-assay <20%
  • ANGPTL4: Intra-assay <10% CV Inter-assay <20%
  • ANGPTL6/AGF: Intra-assay <10% CV Inter-assay <20%
  • FABP1: Intra-assay <10% CV Inter-assay <20%
  • FGF-19: Intra-assay <10% CV Inter-assay <20%
  • FGF-21: Intra-assay <10% CV Inter-assay <20%
  • FGF-23: Intra-assay <10% CV Inter-assay <20%
  • HGF: Intra-assay <10% CV Inter-assay <20%
Panel TypeMAGNETIC Metabolism
Quality LevelMQ200
Applications
ApplicationThe Human Liver Protein Panel, using the Luminex xMAP technology, enables the simultaneous analysis of 9 liver protein biomarkers in human serum, plasma and tissue/cell culture samples.
Key Applications
  • Multiplexing
Application NotesA 2 hour sample incubaton may be used, however, for optimal sensitivity, use an overnight (16-18 hour) incubation. Serum and plasma samples require (recommend) a 1:2 dilution with Assay Buffer. Tissue culture supernatants may be run neat or appropriately diluted in control medium. Each well requires 25 μL of sample, standard or control.
Biological Information
SpecificityThe ANGPTL6 standard had cross reactivity with the ANGPTL4 assay of less than 2%. For all other analytes, there was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.
Species Reactivity
  • Human
Analytes Available
  • AFP
  • ANGPTL3
  • ANGPTL4
  • ANGPTL6/AGF
  • FABP1
  • FGF-19
  • FGF-21
  • FGF-23
  • HGF
Assay PanelEverything you need in a single kit.
Cross ReactivityThe ANGPTL6 standard had cross reactivity with the ANGPTL4 assay of less than 2%. For all other analytes, there was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.
Accuracy
  • AFP 94.2%
  • ANGPTL3 93.7%
  • ANGPTL4 96.8%
  • ANGPTL6 99.1%
  • FABP1 96.6%
  • FGF-19 98.0%
  • FGF-21 98.8%
  • FGF-23 96.6%
  • HGF 100.2%
Physicochemical Information
Sensitivity
  • MinDC+2SD
  • AFP: 0.144 ng/mL
  • ANGPTL3: 0.725 ng/mL
  • ANGPTL4: 2.150 ng/mL
  • ANGPTL6: 0.847 ng/mL
  • FABP1: 0.218 ng/mL
  • FGF-19: 0.054 ng/mL
  • FGF-21: 0.004 ng/mL
  • FGF-23: 0.014 ng/mL
  • HGF: 0.018 ng/mL
Linearity of DilutionContact technical support for this information
Standard Curve Range
  • AFP: 0.14 - 100 ng/mL
  • ANGPTL3: 0.69 - 500 ng/mL
  • ANGPTL4: 5.49 - 4000 ng/mL
  • ANGPTL6/AGF: 1.37 - 1000 ng/mL
  • FABP1: 0.27 - 200 ng/mL
  • FGF-19: 0.14 - 100 ng/mL
  • FGF-21: 0.01 - 10 ng/mL
  • FGF-23: 0.04 - 30 ng/mL
  • HGF: 0.07 - 50 ng/mL
Dimensions
Materials Information
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Usage Statement
  • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Storage and Shipping Information
Storage ConditionsRecommended storage for kit components is 2 - 8°C.
Packaging Information
Material Size96-well plate
Material Package96 well plate
Transport Information
Supplemental Information
Specifications
Global Trade Item Number
Numer katalogowy GTIN
HLPPMAG-57K 04053252987465

Documentation

Protocols

Title
Protocol- HLPPMAG-57K

MILLIPLEX MAP Human Liver Protein Magnetic Bead Panel - Metabolism Multiplex Assay MSDS

Title

Safety Data Sheet (SDS) 

Brochure

Title
A closer look at immunoassay platforms. Beyond fit for purpse. Bring your biomarkers to life with Immunoassay Platform Solutions.
Custom Immunoassay Menu of Services
The Power of Biomarker Analysis

Technical Info

Title
96 well Template 2 Up
96 well Template Single
HLPPMAG-57K xPonent Protocol Template Version Magpix
HLPPMAG-57K xPonent Standard Template Version Magpix
Quality Control Range Sheet- HLPP-113 and HLPP-213
Quality Control Range Sheet- HLPP-114 and HLPP-214
Quality Control Ranges: Milliplex Human Liver Protein Panel Kit; Milliplex Human Liver Protein Magnetic Bead Panel Kit

Data Sheet

Title
Full Service Custom-built Assays