Millipore Sigma Vibrant Logo
Attention: We have moved. Merck Millipore products are no longer available for purchase on MerckMillipore.com.Learn More

ECM557 QCM™ Leukocyte Transendothelial Migration Assay (Colorimetric, 24 Assays)

View Products on Sigmaaldrich.com
ECM557
1 kit  24 Assays
Purchase on Sigma-Aldrich

Overview

Replacement Information

Key Spec Table

Detection Methods
Colorimetric
Description
Catalogue NumberECM557
Trade Name
  • QCM
  • Chemicon
DescriptionQCM™ Leukocyte Transendothelial Migration Assay (Colorimetric, 24 Assays)
OverviewAlso available: Cell Comb™ Scratch Assay! Get biochemical data from a scratch assay! Click Here

Introduction
Millipore’s Colorimetric QCM™ Leukocyte Transendothelial Cell Migration Assay provides an efficient model to analyze the ability of leukocytes to migrate through the endothelium. The assay is designed with a 3 µm pore size cell culture insert, appropriate for most leukocyte migration. The upper side of the cell culture insert is coated with fibronectin to support the optimal attachment and growth of endothelial cells. The assay allows investigators to evaluate the effects of various factors that influence the transendothelial process.

Precoated cell culture inserts are provided in the Millipore QCM Leukocyte Transendothelial Cell Migration Assay to significantly reduce assay time. Additionally, the assay allows quantitative analysis of leukocyte migration. Following incubation of leukocytes with the endothelial cell layer, migratory cells are stained and quantified with WST-1 reagent and measured using a spectrophotometer. Absorbance correlates with cell migration.
Materials Required but Not Delivered1. Endothelial cells (for example: HUVECs, Cat No. SCCE001)
2. Endothelial cell culture medium (Cat. No. SCME001)
3. Leukocytes and cell culture medium
4. Harvesting buffer: Millipore’s cell detachment solution, Accutase™ (Cat. No. SCR005), EDTA or trypsin-based cell detachment buffer, or other cell detachment formulations as optimized by individual investigators can also be used.
5. Serum-free medium, such as RPMI-1640, DMEM (Cat No. ES-101-B), MEM, etc. containing 0.5% BSA (Cat No. 82-046-4), Pen/Strep (Cat No. TMS-AB2-C).
6. Sterile PBS (Cat No. BSS-1006-B) to wash cells.
7. Distilled water (Cat No. TMS-006-B)
8. (Optional) Chemoattractant or pharmacological agent for addition to culture medium.
9. Low speed centrifuge and tubes for cell harvesting.
10. CO2 incubator appropriate for subject cells.
11. Microplate reader (420 - 480 nm detection) or a spectrophotometer.

Background InformationLeukocytes patrol the vascular system. They must migrate across endothelial barriers in order to recruit to sites of inflammation. This process involves a multistep cascade consisting of leukocyte rolling, adhesion, and transmigration. A quantitative assay for leukocyte transendothelial migration has been described using a modified Boyden chamber system (Roth et al. 1995, Ding et al. 2000). The Boyden chamber system is a two chamber system with a porous membrane providing an interface between these two chambers. Endothelial cells are cultured on top of the porous membrane that is coated with an extracelluar matrix (ECM) protein. Once a confluent layer of cells is established, leukocytes are then added onto the endothelial monolayer. Leukocyte migration across the endothelium is determined by measuring the number of cells that migrate between the endothelial cells, through the porous membrane, to the lower chamber.

References
Product Information
Components
  • 1. Migration Test Plate: (Part No. CS202626) Two 24-well culture plates, each containing 12 human fibronectin-coated cell culture inserts (3 μm pore size), sufficient for the evaluation of 24 test samples
  • 2. TNFα: (Part No. 2004167) One tube - 20 μL at 0.1 mg/mL
  • 3. Cell Stain Solution: (Part No. 20294) One vial - 10 mL
  • 4. WST-1 Reagent: (Part No. CS201370) One vial.
  • 5. Electro Coupling Solution: (Part No. CS201382) One vial - 5 mL.
  • 6. 96 well Stain Quantitation Plate: (Part No. 2005870) One plate.
  • 7. Forceps: (Part No. 10203) 1 pair
Detection methodColorimetric
Quality LevelMQ100
Applications
ApplicationThis Colorimetric QCM Leukocyte Transendothelial Cell Migration Assay provides an efficient model to analyze the ability of leukocytes to migrate through the endothelium.
Application NotesResults of the assay may be illustrated graphically using a bar chart to display optical density (OD) values at 420 - 480 nm.

Additional migration may also be induced or inhibited in test wells through the addition of cytokines or other pharmacological agents.
Figures 2 and 3 demonstrate typical migration results. One should use the data for reference only. This data should not be used to interpret actual assay results.

Biological Information
Physicochemical Information
Dimensions
Materials Information
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Usage Statement
  • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Storage and Shipping Information
Storage ConditionsThe kit is packaged in two individual boxes. ECM557-1 contains components that upon arrival should be stored at 2° to 8°C. ECM557-2 contains TNFα , WST-1, and Electro Coupling Solution that upon arrival should be stored at -20°C. Please refer to kit label for expiration date.
Packaging Information
Material Size1 kit
Material Package24 Assays
Transport Information
Supplemental Information
Specifications
Global Trade Item Number
Catalogue Number GTIN
ECM557 04053252004674

Documentation

QCM™ Leukocyte Transendothelial Migration Assay (Colorimetric, 24 Assays) SDS

Title

Safety Data Sheet (SDS) 

References

Reference overviewPub Med ID
Regulation of chemokine-induced transendothelial migration of T lymphocytes by endothelial activation: differential effects on naive and memory T cells.
Ding, Z, et al.
J. Leukoc. Biol., 67: 825-33 (2000)  2000

10857855 10857855
Characterization of transendothelial chemotaxis of T lymphocytes.
Roth, S J, et al.
J. Immunol. Methods, 188: 97-116 (1995)  1995

8551044 8551044

Brochure

Title
Advancing cancer research: From hallmarks & biomarkers to tumor microenvironment progression
Cell Migration and Invasion: Choosing the Right Assay

User Guides

Title
QCM Leukocyte Transendothelial Migration Assay - Colorimetric

Related Products & Applications

Product Families

Related Products By: Brand Facete

Categories

Life Science Research > Cell Analysis > Cell-based Assays > Angiogenesis & Endothelial Transmigration Assays
Life Science Research > Cell Analysis > Cell-based Assays > Cell Migration Assays