Complete Sterility Testing Solutions for
|
Request Information |
The membrane filtration sterility test is the regulatory method of choice for filterable pharmaceutical products. The test is particularly suitable for samples containing preservative, bacteriostatic or fungistatic compounds, which inhibit microbial growth of potential contaminants. With membrane filtration, microorganisms are retained by a 0.45 µm pore size filter, and all inhibiting compounds are rinsed using a suitable rinse solution. Appropriate media, selected based upon their ability to support the growth of anaerobic and aerobic microorganisms, are then transferred to the membrane filters. A 14-day incubation period is required to obtain final test results. With our new device, we are raising the industry‘s standards, and driving innovation to provide you the most secure and reliable test ever.
Steritest™ NEO devices combined with our peristaltic pump, specific accessories and high quality culture media and rinsing fluids offer an optimized testing process compliant with USP <71>, EU Pharmacopoeia < 2.6.1> and JP Pharmacopoeia <4.06>.
Select the right sterility testing membrane filtration solution according to your sample.
Continuous improvements without re-validation with the newly launched Steritest™ NEO membrane filtration devices. Discover also our new devices with a short needle for cartridge and small soft plastic containers for safer operation. Watch the videos to learn more.
Blue canister base indicates mixed esters of cellulose membrane filters. This membrane provides an optimal filtration flow rate for standard products.
Product No. | Illustration (click to enlarge) |
Description |
---|---|---|
TZHACA210 | New Steritest™ NEO Devices for Liquids in Cartridges (Short Needle) | |
TZHALA210 | Steritest™ NEO Devices for Liquids in Ampoules | |
TZHALA205 | Steritest™ NEO Devices for Liquids in Ampoules (double packed) | |
TZHALA210 | Steritest™ NEO Devices for Liquids in Collapsible Bags | |
TZHALA205 | Steritest™ NEO Devices for Liquids in Collapsible Bags (double packed) | |
TZHALV210 | Steritest™ NEO Devices for Liquids in Large Vials | |
TZHALV205 | Steritest™ NEO Devices for Liquids in Large Vials (double packed) | |
TZHASV210 | Steritest™ NEO Devices for Liquids in Small Vials | |
TZHASV205 | Steritest™ NEO Devices for Liquids in Small Vials (double packed) | |
TZHADV210 | Steritest™ NEO Devices for Soluble Powders in Vials | |
TZHADA210 | Steritest™ NEO Devices for Soluble Powders in Ampoules | |
TZHAMD210 | Steritest™ NEO Devices for Medical Devices and Collapsible Bags | |
TZHASY210 | Steritest™ NEO Devices for Liquids in Syringes | |
TZHAPC210 | Steritest™ NEO Devices for Liquids in Plastic Containers |
Back to our sterility testing membrane filtration solutions list.
I need help to identify the best unit to use with my sample or need more information
Red canister base indicates low absorption Durapore® PVDF membrane and specific drainage design.
This optimizes the rinsing of products that inhibit microbial growth.
Product No. | Illustration (Click to Enlarge) |
Description |
---|---|---|
TZHVCA210 | New Steritest™ NEO Devices for Liquids in Cartridges | |
TZHVAB210 | Steritest™ NEO Devices for Liquids in Ampoules | |
TZHVAB205 | Steritest™ NEO Devices for Liquids in Ampoules (double packed) | |
TZHVAB205 | Steritest™ NEO Devices for Liquids in Collapsible Bags (double packed) | |
TZHVLV210 | Steritest™ NEO Devices for Liquids in Large Vials | |
TZHVLV205 | Steritest™ NEO Devices for Liquids in Large Vials (double packed) | |
TZHVSV210 | Steritest™ NEO Devices for Liquids in Small Vials | |
TZHVSV205 | Steritest™ NEO Devices for Liquids in Small Vials (double packed) | |
TZHVDV210 | Steritest™ NEO Devices for Soluble Powders in Vials | |
TZHVDV205 | Steritest™ NEO Devices for Soluble Powders in Vials (double packed) | |
TZHVMD210 | Steritest™ NEO Devices for Medical Devices and Collapsible Bags | |
TZHVAB210 | Steritest™ NEO Devices for Powders and Superpotent Antibiotics |
Back to our sterility testing membrane filtration solutions list.
I need help to identify the best unit to use with my sample or need more information
Green canister base indicates low absorption Durapore® PVDF membrane, specific drainage design and polyamide canister polymer. This optimizes the chemical compatibility for products dissolved in solvents.
Product No. | Illustration (Click to Enlarge) |
Description |
---|---|---|
TZHVSL210 | Steritest™ NEO Devices for Solvents, Creams, Ointments, and Veterinary Injectables | |
1.46628 | Sterile Irradiated Isopropyl Myristate (IPM) |
Back to our sterility testing membrane filtration solutions list.
I need help to identify the best unit to use with my sample or need more information
Product No. | Illustration (Click to Enlarge) |
Description |
---|---|---|
TZV000010 | Steridilutor® NEO Devices without Expansion Chamber for Sample Preparation and Dilution | |
TZVC00010 | Steridilutor® NEO Devices with Expansion Chamber for Sample Preparation and Dilution | |
TZA000010 | Steridilutor® NEO Devices for Liquid Transfer | |
TEFG02525 | Steritest™ Sterile Vent Needles |
Back to our sterility testing membrane filtration solutions list.
I need help to identify the best unit to use with my sample or need more information
Discover our full sterility testing portfolio based on over 40 years of experience and expertise
Pumps | Accessories | Devices | Media & Fluids | Services |