Millipore Sigma Vibrant Logo
Attention: We have moved. Merck Millipore products are no longer available for purchase on MerckMillipore.com.Learn More

KVGLA04NN3 Opticap® XL4 Durapore® 0.22 µm 1/4 in. NPT/NPT

KVGLA04NN3
3  Double Easy-Open bag
Purchase on Sigma-Aldrich

Overview

Replacement Information
Description
Catalogue NumberKVGLA04NN3
ReplacesKVGL04NP3
Trade Name
  • Opticap®
DescriptionOpticap® XL4 Durapore® 0.22 µm 1/4 in. NPT/NPT
References
Product Information
HS Code8421 29 90
Device ConfigurationCapsule
Connections, Inlet/Outlet6 mm (1/4 in.) NPTM
Connections, Vent/Drain1/4 in. Hose Barb with double O-ring Seal
Housing MaterialPolypropylene (PP)
Maximum Differential Pressure, bar (psid)Forward: 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 3.4 bar (50 psid) @ 25 °C, intermittent
Maximum Inlet Pressure, bar (psi)5.5 bar (80 psi) @ 23 °C; 2.8 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
European Pressure Equipment DirectiveEMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Quality LevelMQ400
Applications
Biological Information
Bacterial EndotoxinsAqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
MediaDurapore®
SterilityOther
Sterilization3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
WettabilityHydrophilic
Physicochemical Information
Pore Size0.22 µm
Inlet ConnectionNPT
Outlet ConnectionNPT
Air Diffusion at 23 °C≤5.5 mL/min @ 2.75 bar (40 psig) in water
Bubble Point at 23 °C≥3450 mbar (50 psig) air with water
Gravimetric ExtractablesThe extractables level was equal to or less than 10 mg per capsule after 24 hours in water at controlled room temperature.
Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Maximum Inlet Pressure (psig)80 psig
Maximum Inlet Temperature25 °C
Non-Fiber ReleasingThis product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Dimensions
Cartridge Nominal Length4 in. (10 cm)
Length17.8 cm (7.0 in.)
Diameter12.5 cm (4.9 in.)
Filtration Area0.19 m²
Inlet to Outlet Width17.8 cm (7.0 in.)
Device Size4 in.
Inlet Connection Diameter1/4 in.
Outlet Connection Diameter1/4 in.
Materials Information
Chemistry
  • Polyvinylidene Fluoride (PVDF)
Device Material
  • Polypropylene
Seal MaterialSilicone (SI)
Support MaterialPolypropylene
Vent Cap MaterialPolypropylene (PP)
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Storage and Shipping Information
Packaging Information
Material Size3
Material PackageDouble Easy-Open bag
Transport Information
Supplemental Information
Specifications
Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥500 mL
Global Trade Item Number
Catalogue Number GTIN
KVGLA04NN3 04053252559358

Documentation

Material Qualification Dossier

TitleVersion
1.0

Quality Management Dossier (Open Access)

Title

Operational Excellence Dossier

Title

Opticap® XL4 Durapore® 0.22 µm 1/4 in. NPT/NPT SDS

Title

Safety Data Sheet (SDS) 

Certificates of Quality

Title
OPTICAP XL 4 Capsule Durapore Membrane C2SB51461Z
OPTICAP XL 4 Capsule Durapore Membrane C3AB77668
OPTICAP XL 4 Capsule Durapore Membrane C3CB90717
OPTICAP XL 4 Capsule Durapore Membrane C3MB30619
OPTICAP XL 4 Capsule Durapore Membrane C3MB33889
OPTICAP XL 4 Capsule Durapore Membrane C3PB62399
OPTICAP XL 4 Capsule Durapore Membrane C4AB66768
OPTICAP XL 4 Capsule Durapore Membrane C4NB00747
OPTICAP XL 4 Capsule Durapore Membrane C4NB94164
Opticap XL 4 Capsule Durapore Membrane C0SB75256Z

Technical Info

Title
Autoclaving Guidelines for Opticap® XL and XLT Disposable Capsule Filters
Establishing Product Specific Bubble Point Specifications For Sterilizing-Grade Filters
Simplified, efficient sizing of sterilizing-grade normal flow filters for buffer solutions

Data Sheet

Title
Durapore® Family Guide

User Guides

Title
Opticap® XL Capsules and Opticap® XLT Capsules

Related Products & Applications

Product Families

Related Products By: Brand Facete

Categories

Biopharmaceutical Manufacturing > Downstream Processing > Sterile Filtration > Sterile Liquid > Durapore