Millipore Sigma Vibrant Logo
Attention: We have moved. Merck Millipore products are no longer available for purchase on MerckMillipore.com.Learn More

KTGRA10FF1 Aervent KTGR Opticap XL10 Capsule

KTGRA10FF1
1  Double Easy-Open bag
Purchase on Sigma-Aldrich

Overview

Replacement Information
Description
Catalogue NumberKTGRA10FF1
Trade Name
  • Aervent®
DescriptionAervent KTGR Opticap XL10 Capsule
References
Product Information
HS Code8421 29 90
Device ConfigurationCapsule
Connections, Inlet/Outlet19 mm (3/4 in.) Sanitary Flange
Connections, Vent/Drain1/4 in. Hose Barb with double O-ring Seal
Housing MaterialPolypropylene (PP)
Maximum Differential Pressure, bar (psid)Forward: 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 4.1 bar (60 psid), intermittent
Maximum Inlet Pressure, bar (psi)Forward - 5.5 bar (80 psi) @ 25 °C; 2.8 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C; Reverse - 4.1 bar (60 psi), Intermittent
European Pressure Equipment DirectiveEMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 2014/68/EU of 15 May 2014. This product has been classified under Article 4 § 3 of the Directive 2014/68/EU. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 4 § 3 of the Directive 2014/68/EU, this product does not bear the CE mark.
Quality LevelMQ400
Applications
Biological Information
MediaAervent®
Sterilization30 autoclave cycles of 30 min @ 135 °C
Bacterial Grow-ThroughRetains Brevundimonas diminuta liquid aerosol for 21 days at a minimum challenge of 10⁷ CFU/cm²
Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
WettabilityHydrophobic
Physicochemical Information
Pore Size0.2 µm
Inlet ConnectionSanitary Flange
Outlet ConnectionSanitary Flange
Air Diffusion at 23 °C≤24 mL/min @ 965 mbar (14 psig) in 70/30 % IPA/water
Bubble Point at 23 °C≥1100 mbar (16 psig) nitrogen with 70/30 % IPA/water
Gravimetric ExtractablesThe extractables level was equal to or less than 45 mg per 10-inch cartridge after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
HydroCorr≤0.75 mL/min @ 2.6 bar (38 psig) per sample
Nitrogen Diffusion at 23 °C≤24 mL/min @ 970 mbar (14 psig) in 70/30 % IPA/water
Maximum Inlet Pressure (psig)80 psig
Maximum Inlet Temperature25 °C
Non-Fiber ReleasingThis product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
USP Bacterial EndotoxinsAqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Dimensions
Cartridge Nominal Length10 in. (25 cm)
Length33.0 cm (13.0 in.)
Diameter10.7 cm (4.2 in.)
Filtration Area0.65 m²
Inlet to Outlet Width33.0 cm (13.0 in.)
Device Size10 in.
Inlet Connection Diameter3/4 in.
Outlet Connection Diameter3/4 in.
Materials Information
Chemistry
  • Polytetrafluoroethylene (PTFE)
Device Material
  • Polypropylene
Seal MaterialSilicone (SI)
Support MaterialPolypropylene
Vent Cap MaterialPolypropylene (PP)
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Storage and Shipping Information
Packaging Information
Material Size1
Material PackageDouble Easy-Open bag
Transport Information
Supplemental Information
Specifications
Global Trade Item Number
Catalogue Number GTIN
KTGRA10FF1 04053252603686

Documentation

Certificates of Quality

Title
Opticap XL 10 Capsule Aervent Membrane C7HA24962
Opticap XL 10 Capsule Aervent Membrane C7PA85203
Opticap XL 10 Capsule Aervent Membrane C7EA07307
Opticap XL 10 Capsule Aervent Membrane C8EA81409
Opticap XL 10 Capsule Aervent Membrane C9MA91610
Opticap XL 10 Capsule Aervent Membrane - C7DA01363
Opticap XL 10 Capsule Aervent Membrane - C7NA70250
Opticap XL 10 Capsule Aervent Membrane - C8CA38911
Opticap XL 10 Capsule Aervent Membrane - C8NA50004
Opticap XL 10 Capsule Aervent Membrane C1MB51498

Technical Info

Title
Autoclaving Guidelines for Opticap® XL and XLT Disposable Capsule Filters
Bubble Point Test Method Using Aervent 0.2 µm Hydrophobic Membrane with 60/40 IPA

Data Sheet

Title
Sterilizing-Grade Aervent®Filters

User Guides

Title
Opticap® XL Capsules and Opticap® XLT Capsules