Millipore Sigma Vibrant Logo

IPSN08132 Membrana Immobilon-P para sándwich de transferencia intercalado con papel de transferencia de 8,5 x 13,5 cm

View Products on Sigmaaldrich.com
IPSN08132
20  
Recuperando precio...
No pudo obtenerse el precio
La cantidad mínima tiene que ser múltiplo de
Maximum Quantity is
Al finalizar el pedido Más información
Ahorró ()
 
Solicitar precio
Disponibilidad a confirmar
Disponibilidad a confirmar
Ingrese cantidad 
Suspendido
Cantidades limitadas disponibles
Debe confirmarse disponibilidad
    El resto: se avisará
      El resto: se avisará
      Se avisará
      Póngase en contacto con el Servicio de Atención al Cliente
      Contact Customer Service

       

      Póngase en contacto con el Servicio de Atención al Cliente

      Descripción

      Replacement Information

      Tabla espec. clave

      Aplicaciones clave
      WB
      Descripción
      Número de catálogoIPSN08132
      Nombre comercial
      • Immobilon
      DescripciónMembrana Immobilon-P para sándwich de transferencia intercalado con papel de transferencia de 8,5 x 13,5 cm
      Información preliminarOverview
      - Millipore offers four different Immobilon PVDF membranes, each optimized for different protein blotting applications.
      Immobilon PVDF membranes provide many advantages compared to nitrocellulose. They won’t crack or curl, and they can be cut without fracturing. They also have low background, broad solvent compatibility, and superior staining capabilities. In addition, they can be reprobed multiple times.

      Immobilon-P Transfer Membrane:
      - 45 µm pore size Recommended for most western blotting, especially proteins greater than 20 kDa
      - Millipore's Rapid Immunodetection Protocol reduces detection times by up to 2 hours by eliminating membrane blocking and several wash steps with no loss of sensitivity or specificity

      Immobilon-E Membrane:
      - the only PVDF membrane that wets out in aqueous buffers, eliminating the methanol pre-wet step.
      - 45 µm pore size recommended for most western blotting, especially proteins greater than 20 kDa

      Blotting Sandwiches:
      - When you need to process multiple blots, blotting sandwiches are a convenient, time-saving choice. Our sandwiches include sheets of Immobilon-P membrane interleaved with pre-cut sheets of chromatography-grade blotting filter paper and are compatible with any standard wet transfer device.

      Blotting Filter Paper:
      - Chromatography-grade blotting filter paper pre-cut to the most popular western blotting sizes.

      Immobilon-PSQ Membrane:
      - 0.2 µm pore size and a large internal structure
      - Higher protein adsorption and sequencing yields than other membranes
      - Recommended for blotting proteins less than 20 kDa
      - Prevents blow-through of low molecular weight proteins

      Immobilon-FL Membrane:
      - The first transfer membrane optimized for fluorescence applications
      - Extremely low background improves sensitivity of all fluorescence detection protocols
      - Compatible with all commonly used fluorescent probes at all excitation and emission wavelengths
      - Ideal for multiplexing and chemifluorescence applications

      Immobilon® PVDF membranes are offered in four types, each optimized for a different protein blotting application. Convenient blotting sandwiches feature pre-cut sheets of membrane and blotting filter paper. Immobilon® PVDF membranes have high protein adsorption, so you won’t lose proteins during transfer or reprobing. The open pore structure makes it easy to access bound proteins and remove unbound probes. In addition, Immobilon® PVDF membranes optimized for fluorescent blots dramatically increase signal-to-noise ratios for high sensitivity in quantitative, multiplexing applications.

      Features & Benefits:
      - Won’t crack, curl or fracture when cut
      - Low background
      - Superior staining capabilities
      - Can be reprobed multiple times

      Applications:
      - Western Blotting, Immunoblotting, Dot Blotting, Protein Sequencing;
      - Compatible with Chemiluminescent, Fluorescent, Radioactive, Chromogenic, and Chemifluorescent Detection
      - Compatible with all commonly used fluorescent probes at all excitation and emission wavelengths
      Referencias bibliográficas
      Información del producto
      Método de detecciónQuimioluminiscencía Cromogénico Radioactivo
      Código HS 8421 99 99
      Código del filtroIPSN
      Color del filtroBlanco
      Quality LevelMQ400
      Aplicaciones
      Aplicación 8.5 x 13.5 cm, Immobilon-P membrane interleaved with blotting paper,for standard tank transfer procedures
      Aplicaciones clave
      • Western Blotting
      Información biológica
      Adsorción de BSA215 µg/cm²
      Adsorción de IgG de cabra294 µg/cm²
      Adsorción de insulina160 µg/cm²
      HumectabilidadHidrófoba
      Información fisicoquímica
      Tamaño de poro0.45 µm
      Dimensiones
      Superficie del filtroLisa
      Dimensiones del filtro8.5 cm x 13.5 cm
      Información de materiales
      Química
      • PVDF hidrófobo
      • Papel
      Información toxicológica
      Información de seguridad según el GHS
      Información de seguridad
      Declaraciones de uso del producto
      Información de almacenamiento y transporte
      Información sobre embalaje
      Cantitad20
      Información de transporte
      Información complementaria
      Especificaciones
      Global Trade Item Number
      Número de referencia GTIN
      IPSN08132 04053252620997