Millipore Sigma Vibrant Logo

Centrifree® Ultrafiltration Device

Separate free from bound solutes

Recursos relacionados

Descripción

Especificaciones

Información para pedidos

Centrifree Ultrafiltration DeviceBorrar Clasificación y Filtrado Show Filter
Número de referenciaDescripciónTamaño de envase
4104Unidad de ultrafiltración Centrifree con membrana Ultracel YM-T 50 Precios y disponibilidad

Volver al principio

Documentation

Referencias bibliográficas

Visión general referenciasAplicación
Fractionation of canine serum magnesium.
Schenck PA.,Vet Clin Pathol. 2005 Jun;34(2):137-9.
Vet Clin Pathol. 2005 Jun;34(2):137-9.  2004

The indirect effect of Tityus discrepans on rabbit pulmonary vasculature.
Novoa, Eva, et al.
Respiratory physiology & neurobiology, 134: 33-41 (2003)  2003

Mostrar resumen
Cell Culture
Metabolic activity of cultured rat brainstem, hippocampal and spinal cord slices.
Caroline A. Connelly, Lawrence C. Chen and Steven D. Colquhoun
Journal of Neuroscience Methods 99 (1-2): 1-7  1999

Cell Culture
Adaptation of total phenytoin reagent pack for measuring free phenytoin levels with the Abbott AxSYM immunoassay analyzer
Jarzabek JI (REPRINT) ; Kampa IS
Therapeutic drug monitoring 1999, v21, n1, p134-136  1998

Phenylalanine and tyrosine quantification by stable isotope dilution liquid chromatography-mass spectrometry from filter paper blood spots
Tuchman, M. McCann, M. T.
Clinical Chemistry (Washington, D. C.) VO- 45 IS- 4 PG- 571-573 Apr 1999  1998

Sample Prep
Circadian rhythm of free melatonin in human plasma
Kennaway DJ (REPRINT) ; Voultsios A
JOURNAL OF CLINICAL ENDOCRINOLOGY AND METABOLISM, 1998, V83, N3 MAR, P1013-1015  1998

Clinical Lab, Protein Binding
Factors affecting the free plasma fraction of phenytoin in patients with epilepsy
Jimenez MC; Duran JA (REPRINT) ; Abadin JA
Clinical drug investigation, 1998, V15, P153-157  1998

Clinical Lab
Differential analysis of blood urea using combined automated ultrafiltration and solid phase extraction in on-line series
Shintani H.,Journal of Liquid Chromatography and Related Technologies (2205-2210) 1998
Journal of Liquid Chromatography and Related Technologies (2205-2210) 1998  1998

Effects of tryptophan depletion vs. catecholamine depletion in patients with seasonal affective disorder in remission with light therapy
Neumeister, Alexander et al.
Archives of general psychiatry, 1998  1998

Valproic acid-ketoconazole interaction in normal, hypoalbuminemic, and uremic sera: Lack of interaction in uremic serum caused by the presence of inhibitor
Dasgupta Amitava(a); Luke Matthew; Therapeutic Drug Monitoring VO- 19 IS- 3 PG- 281-285 June, 1997 SN- 0163-4356
Therapeutic Drug Monitoring VO- 19 IS- 3 PG- 281-285 June, 1997 SN- 0163-4356  1997

Preguntas frecuentes

PreguntaRespuesta
Can I use Centrifree with a swinging-bucket rotor?Yes, but the filtration rate will be only 30-50% of that produced with a fixed-angle rotor at the same g-force.
What are the pore and retention characteristics of the YMT 30,000 molecular weight cut-off membrane for Centrifree micropartition device?The actual pore size is not measured. The membrane is characterized by measuring its retention of known protein markers of specific molecular weights. The given cut-off is a nominal measurement.
Does Centrifree have a shelf life?Yes, one year.
What is the maximum spinning speed of the Centrifree unit?Device limits are measured in g-force, not rpm. The maximum recommended g-force is 2000 × g.
How much ultrafiltrate can I expect when using the Centrifree?For volumes less than 0.5 ml: For a sample volume of 1.0 ml: In 10 minutes: I 1/2 the initial volume approximately 200 µl In 30 minutes: 2/3 to 3/4 the initial volume approximately 450 µl
What is the maximum process volume for the Centrifree device?Maximum volume is 1.0 ml.
What molecular weight cut-off does the Centrifree come in?The Centrifree unit is available in a 30,000 MW cut-off.
Can I reuse Centrifree?No, Centrifree is intended for one-time use only. Multiple use risks membrane failure.
What is the minimum process volume for the Centrifree device?Minimum volume is 0.15 ml.
What temperatures can Centrifree be spun at?Spin devices at 4-50°C. Store at room temperature.