Millipore Sigma Vibrant Logo

Pellicon® XL 50 Ultrafiltration Cassettes

True linear scalability with UF membranes with the same flow path and channel height as larger Pellicon® 2 cassettes. The Pellicon XL 50 allows process development and scaling studies.

Overview

Specifications

Ordering Information

Go
Biomax® PolyethersulfoneClear Sorting & Filtering Show Filter
Catalogue NumberFilter CodeNMWL
PXB005A50Biomax 5 5 kDa Show Pricing & Availability
PXB008A50Biomax 8 8 kDa Show Pricing & Availability
PXB010A50Biomax 10 10 kDa Show Pricing & Availability
PXB030A50Biomax 30 30 kDa Show Pricing & Availability
PXB050A50Biomax 50 50 kDa Show Pricing & Availability
PXB100C50Biomax 100 100 kDa Show Pricing & Availability
PXB300C50Biomax 300 300 kDa Show Pricing & Availability
PXB500C50Biomax 500 500 kDa Show Pricing & Availability
PXB01MC50Biomax 1000 1000 kDa Show Pricing & Availability

Back To Top

Ultracel® Regenerated CelluloseClear Sorting & Filtering Show Filter
Catalogue NumberFilter CodeNMWL
PXC005C50PLCCC 5 kDa Show Pricing & Availability
PXC010C50PLCGC 10 kDa Show Pricing & Availability
PXC030C50PLCTK 30 kDa Show Pricing & Availability
PXC300C50PLCMK 300 kDa Show Pricing & Availability
PXC01MC50PLCXK 1000 kDa Show Pricing & Availability
PXC100C50PLCHK 100 kDa Show Pricing & Availability

Back To Top

AccessoriesClear Sorting & Filtering Show Filter
Catalogue NumberDescription
XXPXLFTKTFittings Adapters and Tubing Show Pricing & Availability
XXPXLSTNDStand for Pellicon® XL Show Pricing & Availability
XX42RES01Reservoir, 500 mL, for LabScale Show Pricing & Availability
XXPXLGAGEGauge 0-60 psi and Connection Fittings Show Pricing & Availability

Each Pellicon® XL device is packaged one per box

Back To Top

Documentation

References

Reference overview
Scaling Up with Tangenital Flow Filtration
Campbell, Melissa; Coons, Elizabeth
GEN; v. 21, no. 16; Sept. 15, 2001, p. 60  2001

Linear Scale Ultrafiltration
van Reis, Robert, Elizabeth M. Goodrich, Christine L. Yson, Leah N. Frautschy, Stephen Dzengeleski, and Herb Lutz
Biotechnology & Bioengineering (September 1997): 737-746.  1997

Clean-Water Permeability as a Determinant of Cleaning Efficacy in Tangential-Flow Filtration Systems
Michaels, Stephen L.; RP016
RP016  1994

Validation of Tangential Flow Filtration (TFF) Systems
Michaels, Stephen L.
Journal of Parenteral Science and Technology (Sept/Oct 1991).  1991

FAQ

QuestionAnswer
What is the sample volume range for the Pellicon II Mini system?The Pellicon II Mini system is capable of volumes in the approximate range of 1- 50 L concentrating down to 100 mL. More or less volume can be processed depending on the individual needs of the operation, ie. process time, sensitivity of product, etc.
What is the part number for the Gauge Kit that is used with the Pellicon XL?Gauge Kit for Pellicon XL Device (0-60 psi):
Part number XXPXLGAGE, 1 per kit. Includes an inlet pressure gauge and t-fitting. This gauge is recommended when the Pellicon is used in the absence of a Labscale TFF system in order to ensure that the pressure on the tubing is known and not allowed to exceed it's recommended maximum.
Can I use TFF systems to separate two proteins based on a significant difference in their respective molecular weights?As a general rule ultrafiltration does not provide high efficiency separations of protein mixtures. However, it may be possible to effect this type of separation between two proteins that have at least 10 X difference in molecular weight and if there is an ultrafiltration membrane available with a NMWL rating between the molecular weight of the two proteins. These separations are also generally more successful with dilute protein solutions and if run at low pressure.

Related Products & Applications

Product Families

Related Products By: Application Facete

Related Products By: Brand Facete

Categories

Biopharmaceutical Manufacturing > Downstream Processing > Ultrafiltration