Millipore Sigma Vibrant Logo

MFHL02GH3 Non-sterilized Millipak® Final Fill 20 Filter Unit 0.45  µm 1/4  in. HB/HB

MFHL02GH3
3  Double Easy-Open bag
Le prix n'a pas pu être récupéré
La quantité minimale doit être un multiple de
Maximum Quantity is
À la validation de la commande Plus d'informations
Vous avez sauvegardé ()
 
Demander le prix
Disponibilité limitée
Disponibilité limitée
En stock 
Interrompu(e)
Disponible en quantités limitées
Disponibilité à confirmer
    Pour le restant : Nous vous tiendrons informé
      Pour le restant : Nous vous tiendrons informé
      Nous vous tiendrons informé
      Contacter le Service Clients
      Contact Customer Service

       

      Contacter le Service Clients

      Aperçu

      Description
      Catalogue NumberMFHL02GH3
      Trade Name
      • Millipak®
      DescriptionNon-sterilized Millipak® Final Fill 20 Filter Unit 0.45  µm 1/4  in. HB/HB
      Product Information
      Device ConfigurationCapsule
      Connections, Inlet/Outlet6  mm (¼  in.) stepped hose barb inlet and outlet
      Maximum Differential Pressure, bar (psid)Forward:60 psi (4.1 bar) at 25 °C; 50 psi(3.5 bar) at 25 °C; (5 µm) 25 psi (1.7 bar) at 80 °C; Reverse: 10 psi (0.7 bar) at 25 °C
      Maximum Inlet Pressure, bar (psi)60 psi (4.1 bar) at 25 °C
      Good Manufacturing PracticesThese products are manufactured in a facility which is certified to ISO® 9001:2015 Quality Management Systems.
      Quality LevelMQ400
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains < 0.25 EU/mL per device as determined using the Limulus Amebocyte Lysate (LAL) test, meeting requirements of USP <85>, EP 2.6.14 and JP 4.01.
      MediaDurapore®
      Sterilitynon-sterilized
      SterilizationDevice integrity and retention was maintained after 3 autoclave cycles of 90 minutes at 126  °C. Devices can withstand a dose ≤ 40  kGy gamma exposure.
      WettabilityHydrophilic
      Physicochemical Information
      Pore Size0.45 µm
      Inlet ConnectionStepped Hose Barb
      Outlet ConnectionStepped Hose Barb
      Bubble Point at 23 °C≥ 26 psi (1790 mbar) air with water
      Flow Rate0.51 L/min @ 0.69   bar ∆P
      Non-Fiber ReleasingThis product was manufactured with a Durapore® membrane which meets the criteria for a “non-fiber releasing” filter as defined in 21 CFR 210.3 (b)(6), validated based on large volume parenteral specifications as detailed in USP <788> Particulate Matter in Injections
      USP Bacterial EndotoxinsAqueous extraction contains < 0.25 EU/mL per device as determined using the Limulus Amebocyte Lysate (LAL) test, meeting requirements of USP <85>, EP 2.6.14 and JP 4.01.
      Dimensions
      Filtration Area100 cm²
      Process Volume20 L
      Inlet Connection Diameter1/4 in.
      Outlet Connection Diameter1/4 in.
      Materials Information
      Chemistry
      • Polyvinylidene Fluoride (PVDF)
      Device Material
      • Polysulfone
      Support MaterialPolysulfone
      Packaging Information
      Material Size3
      Material PackageDouble Easy-Open bag
      Global Trade Item Number
      Référence GTIN
      MFHL02GH3 04054839378270