Millipore Sigma Vibrant Logo

SCT254 BioTracker™ FQ Orange Cox-2 Live Cell Probe

SCT254
500 μg  
Prix en cours de récupération
Le prix n'a pas pu être récupéré
La quantité minimale doit être un multiple de
Maximum Quantity is
À la validation de la commande Plus d'informations
Vous avez sauvegardé ()
 
Demander le prix
Disponibilité limitée
Disponibilité limitée
En stock 
Interrompu(e)
Disponible en quantités limitées
Disponibilité à confirmer
    Pour le restant : Nous vous tiendrons informé
      Pour le restant : Nous vous tiendrons informé
      Nous vous tiendrons informé
      Contacter le Service Clients
      Contact Customer Service

       

      Contacter le Service Clients

      Aperçu

      Replacement Information
      Description
      Catalogue NumberSCT254
      Erreur de configuration des données. Pagelet <feature_brand-BioTracker> non trouvé.
      DescriptionBioTracker™ FQ Orange Cox-2 Live Cell Probe
      OverviewFluorocoxib-Q (FQ) Orange is a redox-activatable probe suitable for live cell imaging of COX-2. In contrast to other COX-2 reactive compounds such as fluorocoxib-A, FQ Orange produces fluorescent signal only in a redox environment characteristic of cells with high COX-2 expression.
      Active COX-2 is localized to the outer nuclear membrane and endoplasmic reticulum. The localization of FQ Orange probe signal in colorectal cancer cells is consistent with the nuclear periphery, as demonstrated by nuclear counterstaining with Hoechst.

      FQ Orange has also demonstrated utility in vivo tumor imaging (2).

      MW=1098.78 g/mol
      Probe is soluble in DMSO.


      For representative data, SCC736 Human Colorectal Organoids were incubated with 200 nM FQ probe in appropriate growth medium for 3 hours

      SPECTRAL PROPERTIES

      Excitation max λ: 586 nm
      Emission max λ: 607 nm
      Activated BioTracker™ FQ Orange Cox-2 Live Cell Probe is detectable using a 561 nm laser excitation and a propidium iodide/Texas Red filter.

      REFERENCES
      1. Chan G et al. Cyclooxygenase-2 expression is up-regulated in squamous cell carcinoma of the head and neck. Cancer Res 59(5):991-994 (1999)
      2. Uddin MJ et al. Discovery of a redox-activatable chemical probe for detection of cyclooxygenase-2 in cells and animals. ACS Chem Biol 17:1714-1722 (2022)
      Alternate Names
      • COX-2 live cell probe
      • cyclooxygenase-2 live cell probe
      • cyclooxygenase-2 live cell dye
      • COX-2 live cell dye
      • FQ live cell probe
      Background InformationCyclooxygenase-2 is an enzyme that catalyzes the formation of prostaglandin H2, a branch point in the biosynthetic pathway leading to the bioactive lipids prostaglandin, thromboxane, and prostacyclin. These compounds function in processes including inflammation, platelet aggregation, and gastric cytoprotection. COX-2 is highly regulated and its expression is induced by a wide range of cytokines, growth factors, and tumor promoters, making COX-2 a key enzyme in inflammatory responses and neoplastic tissues. For example, COX-2 is a marker for colon cancer tumorigenesis, being highly expressed in colorectal carcinoma but nearly undetectable in surrounding normal tissue. (1). The importance of COX-2 expression especially as a preneoplastic/tumorigenic marker thus highlights the need for in vivo detection reagents.
      References
      Product Information
      Detection methodFlow cytometry Fluorescence
      FormatLyophilized solid
      PresentationDark blue solid. Upon reconstitution, probe solution is clear.
      Quality LevelMQ100
      Applications
      ApplicationThis orange fluorescent probe detects cyclooxygenase-2 (COX-2)---a key enzyme associated with inflammatory processes and neoplasia---in live cells.
      Key Applications
      • Cell Based Assays
      • Fluorescence
      • Flow Cytometry
      • Fluorescence Activated Cell Sorting (FACS)
      • In vitro Bioassay
      • Activity Assay
      Application NotesLive cell probe for detection of COX-2 activity by fluorescence microscopy or flow cytometry. Unlike other COX-2 reactive compounds such as fluorocoxib-A, BioTracker™ FQ Orange Cox-2 Live Cell Probe produces fluorescent signal only in a redox environment characteristic of cells with high COX-2 expression.
      Biological Information
      Physicochemical Information
      Dimensions
      Materials Information
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Quality AssurancePurity: ≥ 98% confirmed by HNMR, LC-MS and HPLC and elemental analysis
      Usage Statement
      • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
      Storage and Shipping Information
      Storage ConditionsStore BioTracker™ FQ Orange Cox-2 Live Cell Probe at -20°C, desiccated and protected from light
      Note: Centrifuge vial briefly to collect contents at bottom of vial before opening.
      Packaging Information
      Material Size500 μg
      Transport Information
      Supplemental Information
      Specifications
      Global Trade Item Number
      Référence GTIN
      SCT254 04065270410719