Millipore Sigma Vibrant Logo

S7350 OxyICC™ Oxidized Protein Detection Kit

S7350
40 Reactions in an 8 Chamber Slide  
Retrieving price...
Price could not be retrieved
Minimum Quantity is a multiple of
Maximum Quantity is
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Fulfillment and Delivery Delayed
Fulfillment and Delivery Delayed
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

       

      Contact Customer Service

      Overview

      Replacement Information

      Key Spec Table

      Key ApplicationsDetection Methods
      IF, ICCFluorescent
      Description
      Catalogue NumberS7350
      Trade Name
      • OxyICC
      DescriptionOxyICC™ Oxidized Protein Detection Kit
      OverviewThe OxyICC™ kit provides reagents for immunodetection of protein carbonyls by fluorescent immunocytochemistry. The assay procedure is simple and the results obtained are highly sensitive and quantitative.
      Background Information
      Oxidative stress has been found to play a key role in a number of pathological disorders. These affects appear to be mediated by reactive oxygen species (ROS) which cause modifications to proteins, lipids, and DNA. In the case of proteins the ROS primarily cause carbonyl derivatives on amino acid sidechains affecting their enzymatic and biochemical functionality. Not surprisingly, carbonyl formation has become an important biomarker for oxidative stress.

      Reactive oxygen species (ROS) have been implicated in pathological processes including cancer, apoptosis, aging, neurodegenerative diseases, chronic inflammatory diseases, pulmonary diseases, and cardiovascular diseases (for reviews, see ref. 1-4).

      Living organisms are continually exposed to potentially harmful oxygen free radicals that are generated thru normal cellular functions as well as from environmental factors (1, 5-7). Yet, these reactive molecules are mitigated by the presence of antioxidants and therefore organisms exist with a delicate balance between oxidants and antioxidants (7-9). During times of oxidative stress there is an imbalance in favor of the oxidants. The end result of which is that free radicals are able to attack and modify subcellular components including nucleic acids, lipids and proteins (7, 10-12). In some cases, cells respond to the oxidative stimuli and allow the organism to adapt to the oxidative stress (13-15).

      Proteins are one of the major targets of oxygen free radicals and other reactive species. Oxidation of proteins modifies the side chains of methionine, histidine, and tyrosine and forms cysteine disulfide bonds (16-19). Metal catalyzed oxidation of proteins introduces carbonyl groups (aldehydes and ketones) at lysine, arginine, proline or threonine residues in a site-specific manner (16, 20-22). The oxidative modification of proteins can modulate biochemical characteristics of proteins such as enzymatic activity (21-23), DNA binding activities of transcription factors (24-26), and the susceptibility to proteolytic degradation (12, 25-28). While a relationship between protein oxidation and aging has been suggested (29-31), little is known about the importance of oxidative modification of individual proteins in the pathophysiology of free radical mediated processes.

      Not surprisingly, carbonyl modification of proteins has become a key biomarker for the identification of oxidative stress. To assist in these research efforts Millipore now offers the OxyICC kit which contains the chemical and immunological reagents necessary to detect the carbonyl groups using fluorescent immunocytochemistry. The test method involves chemical derivatization of protein carbonyl groups with 2,4-dinitrophenylhydrazine (DNPH). This chemical reaction results in proteins being covalently coupled to DNP at their carbonyl sites. The DNP-derivatized proteins are then detected using biotinylated antibodies that are specifically reactive for the DNP moiety. Subsequent incubation with fluorescently conjugated streptavidin enables detection using fluorescence microscopy. The amount of fluorescence detected is correlated to the extent of oxidative stress that the cell was subjected to.
      References
      Product Information
      Components
      • S7350-1 (Store at 2-8ºC)
        Streptavidin-Cy3: (Part No. CS203022) 15µL solution.
        2,4-Dinitrophenylhydrazine Solution: (Part No. CS201876) One vial with 1.1mL.
        10x PBS Wash Buffer: (Part No. CS201873) One 130mL bottle.
        5x Blocking Buffer: (Part No. CS203024) One 10mL bottle.
        MILLEX® GP Filter Units (0.22µm): (Part No. SLGP033RB) 3 filters.

        S7350-2 (Store at - 20ºC)
        Anti-DNP, Biotinylated (mouse monoclonal) Antibody: (Part No. CS203021) 15µL of a 1mg/mL solution.
        DAPI: (Part No. CS202687) 10 L of 1mg/mL solution.
      Detection methodFluorescent
      Quality LevelMQ100
      Applications
      ApplicationThe OxyICC kit provides reagents for immunodetection of protein carbonyls by fluorescent ICC.
      Key Applications
      • Immunofluorescence
      • Immunocytochemistry
      Application NotesPeroxide stressed cell protocol:
      - Plate cells normal density (typically add ~30k per well of an 8 well chamber slide).
      - Incubate overnight
      - Remove media
      - Add fresh media containing H2O2 (500uM treatment for 30 minutes or 50uM treatment overnight)
      - After appropriate incubation wash cells gently 2X with PBS
      - Fix cells with ice cold methanol
      - Continue with the OxyICC protocol.
      Biological Information
      Physicochemical Information
      Dimensions
      Materials Information
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Usage Statement
      • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
      Storage and Shipping Information
      Storage ConditionsDual Temperature Storage (See Manual for details) Store for up to 6 months after date of receipt.
      Packaging Information
      Material Size40 Reactions in an 8 Chamber Slide
      Transport Information
      Supplemental Information
      Specifications
      Global Trade Item Number
      Catalogue Number GTIN
      S7350 04053252020452