Millipore Sigma Vibrant Logo

Pellicon® XL 50 Ultrafiltration Cassettes

True linear scalability with UF membranes with the same flow path and channel height as larger Pellicon® 2 cassettes. The Pellicon XL 50 allows process development and scaling studies.

Überblick

Spezifikationen

Bestellinformationen

Los
Biomax, PolyethersulfonSortierung & Filter aufheben Show Filter
BestellnummerFiltercodeNMWL
PXB005A50Biomax 5 5 kDa Preis & Verfügbarkeit
PXB008A50Biomax 8 8 kDa Preis & Verfügbarkeit
PXB010A50Biomax 10 10 kDa Preis & Verfügbarkeit
PXB030A50Biomax 30 30 kDa Preis & Verfügbarkeit
PXB050A50Biomax 50 50 kDa Preis & Verfügbarkeit
PXB100C50Biomax 100 100 kDa Preis & Verfügbarkeit
PXB300C50Biomax 300 300 kDa Preis & Verfügbarkeit
PXB500C50Biomax 500 500 kDa Preis & Verfügbarkeit
PXB01MC50Biomax 1000 1000 kDa Preis & Verfügbarkeit

Zurück nach oben

Ultracel, regenerierte ZelluloseSortierung & Filter aufheben Show Filter
BestellnummerFiltercodeNMWL
PXC005C50PLCCC 5 kDa Preis & Verfügbarkeit
PXC010C50PLCGC 10 kDa Preis & Verfügbarkeit
PXC030C50PLCTK 30 kDa Preis & Verfügbarkeit
PXC300C50PLCMK 300 kDa Preis & Verfügbarkeit
PXC01MC50PLCXK 1000 kDa Preis & Verfügbarkeit
PXC100C50PLCHK 100 kDa Preis & Verfügbarkeit

Zurück nach oben

ZubehörSortierung & Filter aufheben Show Filter
BestellnummerBeschreibung
XXPXLFTKTKlemme, Adapter und Schlauch Preis & Verfügbarkeit
XXPXLSTNDPellicon TFF-Modulhalter Preis & Verfügbarkeit
XX42RES01500-ml-Reservoir für das Labscale TFF-System Preis & Verfügbarkeit
XXPXLGAGEManometer, 0–4 bar Preis & Verfügbarkeit

Pellicon XL-Einheiten werden einzeln verpackt geliefert.

Zurück nach oben

Documentation

Literatur

Übersicht
Scaling Up with Tangenital Flow Filtration
Campbell, Melissa; Coons, Elizabeth
GEN; v. 21, no. 16; Sept. 15, 2001, p. 60  2001

Linear Scale Ultrafiltration
van Reis, Robert, Elizabeth M. Goodrich, Christine L. Yson, Leah N. Frautschy, Stephen Dzengeleski, and Herb Lutz
Biotechnology & Bioengineering (September 1997): 737-746.  1997

Clean-Water Permeability as a Determinant of Cleaning Efficacy in Tangential-Flow Filtration Systems
Michaels, Stephen L.; RP016
RP016  1993

Validation of Tangential Flow Filtration (TFF) Systems
Michaels, Stephen L.
Journal of Parenteral Science and Technology (Sept/Oct 1991).  1991

FAQ

FrageAntwort
What is the sample volume range for the Pellicon II Mini system?The Pellicon II Mini system is capable of volumes in the approximate range of 1- 50 L concentrating down to 100 mL. More or less volume can be processed depending on the individual needs of the operation, ie. process time, sensitivity of product, etc.
What is the part number for the Gauge Kit that is used with the Pellicon XL?Gauge Kit for Pellicon XL Device (0-60 psi):
Part number XXPXLGAGE, 1 per kit. Includes an inlet pressure gauge and t-fitting. This gauge is recommended when the Pellicon is used in the absence of a Labscale TFF system in order to ensure that the pressure on the tubing is known and not allowed to exceed it's recommended maximum.
Can I use TFF systems to separate two proteins based on a significant difference in their respective molecular weights?As a general rule ultrafiltration does not provide high efficiency separations of protein mixtures. However, it may be possible to effect this type of separation between two proteins that have at least 10 X difference in molecular weight and if there is an ultrafiltration membrane available with a NMWL rating between the molecular weight of the two proteins. These separations are also generally more successful with dilute protein solutions and if run at low pressure.

Verwandte Produkte & Anwendungen

Produktfamilien

Verwandte Produkte nach: Application Facete

Verwandte Produkte nach: Brand Facete

Kategorien

Biopharmaceutical Manufacturing > Downstream Processing > Ultrafiltration