크기 선택
제품정보 (DICE 배송 시 비용 별도)
LC/MS: suitable
UHPLC: suitable
410 mmHg ( 50 °C)
97.68 mmHg ( 20 °C)
제품 이름
Methanol, for UHPLC-MS LiChrosolv®
InChI
1S/CH4O/c1-2/h2H,1H3
SMILES string
CO
InChI key
OKKJLVBELUTLKV-UHFFFAOYSA-N
agency
suitable for ASTM® 7968
suitable for ASTM® 7979
suitable for DIN 38407-42
suitable for EPA 1621
suitable for EPA 1633
suitable for EPA 533
suitable for EPA 537.1
suitable for EPA 8327
suitable for EPA ACB B21-02
suitable for EPA ACB B23-05b
suitable for EPA OTM-45
suitable for GB 31604.35-2016
suitable for GB 5009.253-2016
suitable for ISO 21675 2019
suitable for ISO 25101
suitable for ISO/CEN 15968-2010
reg. compliance
suitable for FDA C-010.02
vapor density
1.11 (vs air)
vapor pressure
128 hPa ( 20 °C)
410 mmHg ( 50 °C)
97.68 mmHg ( 20 °C)
product line
LiChrosolv®
assay
99.9% (GC)
form
liquid
autoignition temp.
725 °F
expl. lim.
36 %
technique(s)
HPLC: suitable
LC/MS: suitable
UHPLC: suitable
refractive index
n20/D 1.329 (lit.)
kinematic viscosity
0.54-0.59 cSt(20 °C)
bp
64.7 °C (lit.)
mp
−98 °C (lit.)
transition temp
flash point 9.7 °C
density
0.791 g/mL at 25 °C (lit.)
application(s)
PFAS testing
format
neat
storage temp.
2-30°C
Quality Level
유사한 제품을 찾으십니까? 방문 제품 비교 안내
Analysis Note
Application
The product is used as a solvent in studies such as the following:
- high resolution mass spectrometric (HRMS) analysis of per- and polyfluoroalkyl substances (PFAS) in environmental water samples
- UHPLC-MS/MS study of PFAS and/or perfluorooctane sulfonate (PFOS) in sewage sludge and soil samples
Features and Benefits
- suitability tested and specified for UHPLC-MS and UHPLC-UV: for analytical flexibility
- specified quality in positive and negative in positive and negative electrospray ionization (ESI) and atmospheric-pressure chemical ionization-mass spectrometry (APCI-MS) for lowest detection limits and confidence in analyses for all important MS modes (test 1)
—ESI/APCI (-) < 10 ppb
- lowest impurity profile: for interference-free baselines (test 2)
- microfiltered through 0.2 μm filter (test 3) to provide:
—reduced risk of column clogging
- packed in borosilicate glass bottles for minimized metal ion contaminations
- lowest levels of trace metal impurities for a minimum metal ion adduct formation
- lowest level of polyethylene glycol (PEG) impurities in UHPLC-MS solvent lineup (PEG S/N signal-to-noise-ratio < 50)
General description
Other Notes
Legal Information
signalword
Danger
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
target_organs
Eyes,Central nervous system
저장 등급
3 - Flammable liquids
wgk
WGK 2
flash_point_f
49.5 °F - closed cup
flash_point_c
9.7 °C - closed cup
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
문서
Accurate steroid analysis in blood serum using Supel™ Swift HLB DPX Tips; UTAK and NIST standards.
Nitrosamines analysis by solid phase extraction (SPE) and subsequent gas chromatography-tandem mass spectrometry (GC-MS/MS) according to GB 5750.10-2023.
Pesticide residue analysis of 331 pesticides and 44 metabolites in cabbage samples using Supel™ QuE QuEChERS mixes and Purospher® STAR RP-18e column.
Simultaneous LC-MS/MS determination of vitamins D₂ and D₃ in infant milk powder meeting GB 5009.296-2023 criteria for accuracy and sensitivity.
관련 콘텐츠
Discover our complete solutions: Reliable products and precision tools to more accurately quantify PFAS compounds in diverse samples including water, wastewater, soil, food, blood, etc.
전체 솔루션을 알아보세요. 신뢰할 수 있는 제품과 정밀한 툴로 물, 폐수, 흙, 식품, 혈액 등이 포함된 다양한 샘플에서 PFAS 화합물의 양을 더욱 정확하게 측정할 수 있습니다.
국제 무역 품목 번호
| SKU | GTIN |
|---|---|
| 1.03726.1002 | 04054839477225 |
| 1.03726.2002 | 04054839477331 |
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.