Millipore Sigma Vibrant Logo

MFGL10GT3 Non-sterilized Millipak® Final Fill 100 Filter Unit 0.22  µm 1 1/2  in. TC/TC

MFGL10GT3
3  Double Easy-Open bag
가격을 검색할 수 없습니다
Minimum Quantity needs to be mulitiple of
Maximum Quantity is
가격 문의 추가 정보
()이 할인됨
 
가격 문의
현재 재고 없음
현재 재고 없음
예상 출고 가능일 
단종품
제한된 수량 가능
재고여부 확인
    Remaining: will advise
      Remaining: will advise
      추천사항
      고객 서비스로 문의
      Contact Customer Service

       

      고객 서비스로 문의

      개요

      Description
      Catalogue NumberMFGL10GT3
      Trade Name
      • Millipak®
      DescriptionNon-sterilized Millipak® Final Fill 100 Filter Unit 0.22  µm 1 1/2  in. TC/TC
      Product Information
      HS Code8421 29 90
      Device ConfigurationCapsule
      Connections, Inlet/Outlet38  mm (1½  in.) sanitary flange inlet and outlet
      Maximum Differential Pressure, bar (psid)Foward:80 psi (5.5 bar) at 25 °C (0.1 µm, 0.22 µm, 0.45 µm, hydrophobic 0.22 µm); Reverse: 10 psi (0.7 bar) at 25 °C
      Maximum Inlet Pressure, bar (psi)80 psi (5.5 bar) at 25 °C
      Good Manufacturing PracticesThese products are manufactured in a facility which is certified to ISO® 9001:2015 Quality Management Systems.
      Quality LevelMQ400
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains < 0.25 EU/mL per device as determined using the Limulus Amebocyte Lysate (LAL) test, meeting requirements of USP <85>, EP 2.6.14 and JP 4.01.
      MediaDurapore®
      Sterilitynon-sterilized
      SterilizationDevice integrity and retention was maintained after 3 autoclave cycles of 90 minutes at 126  °C. Devices can withstand a dose ≤ 40  kGy gamma exposure.
      Bacterial RetentionQuantitative retention of 107 CFU/cm2 Brevundimonas diminuta ATCC® 19146 per AST® F838 methodology.
      WettabilityHydrophilic
      Physicochemical Information
      Pore Size0.22 µm
      Inlet ConnectionSanitary Flange
      Outlet ConnectionSanitary Flange
      Bubble Point at 23 °C≥ 50 psi (3450 mbar) air with water
      Flow Rate3.81 L/min @ 1.1   bar ∆P
      Non-Fiber ReleasingThis product was manufactured with a Durapore® membrane which meets the criteria for a “non-fiber releasing” filter as defined in 21 CFR 210.3 (b)(6), validated based on large volume parenteral specifications as detailed in USP <788> Particulate Matter in Injections
      USP Bacterial EndotoxinsAqueous extraction contains < 0.25 EU/mL per device as determined using the Limulus Amebocyte Lysate (LAL) test, meeting requirements of USP <85>, EP 2.6.14 and JP 4.01.
      Dimensions
      Filtration Area500 cm²
      Process Volume100 L
      Inlet Connection Diameter1 1/2 in.
      Outlet Connection Diameter1 1/2 in.
      Materials Information
      Chemistry
      • Polyvinylidene Fluoride (PVDF)
      Device Material
      • Polysulfone
      Support MaterialPolysulfone
      Packaging Information
      Material Size3
      Material PackageDouble Easy-Open bag
      Global Trade Item Number
      카탈로그 번호 GTIN
      MFGL10GT3 04054839379185