Millipore Sigma Vibrant Logo

MultiScreen®HTS Vacuum Manifold

For vacuum filtration of 96 and 384 samples

관련 자료

개요

사양

주문 정보

실행
MultiScreenHTS Vacuum Manifold for use with 96- and 384-well MultiScreenHTS filter plates as well as MultiScreen Solvinert and Solvinert Deep Well filter plates정렬 및 필터링 지우기 Show Filter
카탈로그 번호DescriptionComponentsPack Size
MSVMHTS00MultiScreenHTS Vacuum Manifold
  • includes manifold base, standard collar, gaskets, gasket inserts, all tubing, valves, and pressure gauge
1 가격 및 재고 조회

위로 돌아가기

Adapters for MultiScreenHTS Vacuum Manifold정렬 및 필터링 지우기 Show Filter
카탈로그 번호DescriptionPack Size
MSVMHTS0DDeep Well Collar 1 가격 및 재고 조회
MSVMHTS0HCollar Holder, for automation 1 가격 및 재고 조회

위로 돌아가기

Replacement Parts정렬 및 필터링 지우기 Show Filter
카탈로그 번호DescriptionPack Size
MSVMHTS04Replacement Gasket Set 1 가격 및 재고 조회
MSVMHTS06On/Off Valve Kit 1 가격 및 재고 조회
MSVMHTS10Control Valve Kit 1 가격 및 재고 조회
MSVMHTS07Vacuum Gauge Kit 1 가격 및 재고 조회
MSVMHTS08Standard Collar with gasket 1 가격 및 재고 조회
MSVMHTS09Replacement Tubing, 10 ft (3 m) 1 가격 및 재고 조회

위로 돌아가기

MultiScreen Vacuum Manifold for use with standard MultiScreen (classic) filter plates정렬 및 필터링 지우기 Show Filter
카탈로그 번호DescriptionComponentsPack Size
MAVM0960RMultiScreen™ Vacuum Manifold 96-well
  • includes manifold base, standard ring with gaskets, support grid, all tubing, valves and pressure gauge
1 가격 및 재고 조회

위로 돌아가기

Vacuum Pump - Accessories정렬 및 필터링 지우기 Show Filter
카탈로그 번호DescriptionPack Size
SLFG05010Millex-FG, 0.20 µm, hydrophobic PTFE, 50 mm 10 가격 및 재고 조회
WP6110060Chemical Duty Pump, 100 V/50–60 Hz 1 가격 및 재고 조회
WP6111560Chemical Duty Pump, 115 V/60 Hz 1 가격 및 재고 조회
WP6122050Chemical Duty Pump, 220 V/50 Hz 1 가격 및 재고 조회

위로 돌아가기

Collection Plates정렬 및 필터링 지우기 Show Filter
카탈로그 번호DescriptionSterilityPack Size
MSCPNPS0096-well Collection Plate Non-Sterile 100 가격 및 재고 조회
MSCPNPP0096-well Collection Plate Non-Sterile 100 가격 및 재고 조회
MSCPNUV4096-well Collection Plate Non-Sterile 40 가격 및 재고 조회
MDCPN2M5096 well Collection Plate Non-Sterile 50 가격 및 재고 조회

위로 돌아가기

Sealing Tape정렬 및 필터링 지우기 Show Filter
카탈로그 번호DescriptionSterilityPack Size
MATAHCL00MultiScreen Sealing Tape, clear, non-sterile Non-Sterile 100 가격 및 재고 조회

위로 돌아가기

Documentation

References

Reference overviewApplication
Method for Simultaneous Measurement of Antibodies to 23 Pneumococcal Capsular Polysaccharides
Raymond Biagini, Sonela Schlottmann, Deborah Sammons, Jerome Smith, John Snawder, Cynthia Striley, Barbara MacKenzie, and David Weisssman
Clinical and Diagnostic Laboratory Immunology September 2003, p 744-750, Vol. 10, No. 5  2003

A non-radiolabelled ferriprotoporphyrin IX biomineralisation inhibition test for the high throughput screening of antimalarial compounds.
E. Deharo, R. N. Garcia, P. Oporto, A. Gimenez, M. Sauvain, V. Jullian and H. Ginsburg
Experimental Parasitology 100 (4): 252-256  2002

High-Throughput Microplate Format for Producing and Screening Riboprobes from Bacterial Cells
Matthews, P.D. and Wurtzel, E.T.
BioTechniques. 18: 6, 1000 – 1004  1995

Nucleic Acid Purification and Concentration
Use of Multiscreen plates for the preparation of bacterial DNA suitable for PCR
Reek FH, Smits MA, Kamp EM, Smith HE
Biotechniques. 1995 Aug;19(2):282-5  1995

PCR

FAQ

QuestionAnswer
What plates are compatible with the MultiScreen manifold?In general, all manufacturers' plates fit the vacuum manifold.
I’m not getting good vacuum while using the MultiScreen vacuum manifold, what can I do?Press down on the MultiScreen plate to form a good seal with the manifold. (This is normal for the low vacuum used). Make sure all wells of the filter plate are either “wet” or sealed with adhesive tape. Check all tubing connections to make sure they are tight. See the MultiScreen Vacuum manifold operators guide for more detailed troubleshooting information.
What plates can be used with the MultiScreen HTS manifold (Catalogue number MSVMHTS00)?All MultiScreen HTS platform filter plates, Solvinert and Solvinert Deep Well plates can be used with the HTS manifold.
Can the classic MultiScreen plates be run on the HTS manifold?Only in filter to waste mode. The HTS plates should be used with the HTS manifold for the most benefit.
Can the MultiScreen HTS manifold be used with Millipore's genomics application plates (plamid prep, pcr cleanup, sequence reaction clean up)?Filter to waste modes work, but not filtrate collection, so using the clearing plate with the plamid plate will not work. Millipore's genomics plates have not been validated on the HTS manifold. Please contact technical service for more information at 1-800-645-5476.
If using the MultiScreen HTS manifold, when do I have to use the droplet trap array?The droplet trap array should be used when filtering a 384 well plate to waste.
If the deep well collar sold with the MultiScreen HTS manifold or is it sold seperately?The deep well collar is sold as an accessory to the MultiScreen HTS manifold; it does not come with the manifold. The catalogue number is MSVMHTS0D.
When using the MultiScreen HTS manifold, can I filter to waste when using a shallow well plate?Yes. The classic grid should be in place for removeable underdrain HTS plates or the collar gasket frame should be in place for Solvinert plates.
When using the MultiScreen HTS vacuum manifold, can I filter to waste when using a deep well plate?Yes. The deep well plate should be placed on top of the manifold collar with the clear gasket support installed.
When using the MultiScreen HTS manifold, how can I test to see if the manifold is properly installed and/or that I have enough vacuum for my application?The easiest way to test the manifold and/or set vacuum pressures is to put the collar on the base with nothing inside and place a collection (plastic bottom) plate on the top. You can now adjust the vacuum to the desired level.

관련 제품 및 어플리케이션

제품 패밀리

관련 제품: Application Facete

관련 제품: Brand Facete

카테고리

Life Science Research > Cell Culture and Systems > Cell Culture Flasks, Plates, & Slides > Multiwell Plates