Milli-Q® HXSD Water Purification System

Centralized pure water solution for up to 800 L/day Type 2 water; for low chlorine feed water

동의어(들):

Milli-Q® HX 7040 SD Water Purification System (LC)

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

제품정보 (DICE 배송 시 비용 별도)

NACRES:
JA.13
UNSPSC Code:
41104202
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의

제품 이름

Milli-Q® HXSD Water Purification System, Centralized pure water solution for up to 800 L/day Type 2 water; for low chlorine feed water

AC/DC input

100 - 230 V (For region specific voltage information, see footnote below)

product line

Milli-Q® HX

packaging

pkg of 1 unit

parameter

≤20 L/min distribution flow rate
222 kg operating weight (489.4 lb)
40 L/hr make-up flow rate
800 L/day max. usage

resistivity

>5 Ω-cm, at 25°C

H × W × D

124 cm (48.8 in.) × 54.3 cm (21.4 in.) × 94.7 cm (37.3 in.)

tank volume

140 L

total organic carbon (TOC) residue

<30 ppb

input

feed water nature potable tap water

output

product water quality: type 2 water (> 5 MΩ·cm)

conductivity

<0.2 μS/cm at 25 °C

Quality Level

유사한 제품을 찾으십니까? 방문 제품 비교 안내

Application

Water produced from a Milli-Q® HX 7040 SD systems can reliably feed all your Type 2 pure water needs, including:
  • Equipment and instruments such as dishwashers, autoclaves, clinical analyzers, heating baths, environmental and humidity chambers, and histopathology stainers.
  • Taps on benches for general glassware rinsing, buffer and reagent preparation.
  • Purification systems to obtain ultrapure water (e.g. Milli-Q® IQ 7000 system).

Disclaimer

For U.S. Customers: Contains mercury; Do not place in trash - dispose according to local, state, or federal laws.

Features and Benefits

  • Optimal combination of purification technologies for a reliable flow of high-quality Type 2 pure water.
  • Integrated 140 L reservoir and pump for protected storage and distribution up to 20 L/min.
  • Superior communications interface and modern data management capabilities.
  • Customizable range of options and accessories to meet your specific requirements.
  • MyMilli-Q remote care monitoring and service capability.

General description

  • The Milli-Q® HX 7040 SD system is a complete, compact, connected and fully customizable pure water solution for large laboratories requiring up to 800 L/day of Type 2 pure water. These systems allow a distribution flow of up to 20 L/min for a small and mid-size loop. This enables one Milli-Q HX 7040 SD system to reliably supply the pure water needs of a large laboratory or an entire floor of a building.
  • Tap water is first pretreated by a Progard® cartridge to efficiently remove particles, colloids, free chlorine and hardness. Advanced reverse osmosis (RO) purification delivers high-quality Reverse Osmosis water. Patented E.R.A.® (Evolutive Reject Adjustment) technology automatically assesses feed water quality to produce a constant flow rate and optimize water recovery (between 45% and 75%). The Elix® electrodeionization (EDI) module further removes ions to typically reach resistivity >5 MΩ.cm (at 25 °C).
  • Processed pure water is then irradiated by a bactericidal UV lamp before entering the built-in storage tank.
  • This integrated 140 L water reservoir offers protected storage, plus a distribution pump provides up to 20 L/min pure water for a loop of up to 50 m long. The systems are equipped with a large, colored touchscreen display panel to facilitate maintenance, control and access to data. These central systems are embedded with our unique MyMilli-Q Remote Care online monitoring and service capability, which operates as an extension of Milli-Q® Services. This digital service lets you securely and remotely manage your system, supporting your lab′s optimal productivity.

Other Notes

  • The indicated price currently corresponds to the above catalogue number only; it is subject to change at any time without notice.
  • This catalogue number does not include consumables, accessories and other products and/or services that may be required for the installation and the correct operation of the water purification unit over time.
  • Because our customers each have specific purified water needs, we recommend that you have your purchase validated by one of our specialists. We remain at your disposal to advise you, do not hesitate to contact us!
Directions for Use

  • Organism Retention: Microorganisms
  • Mode of Action: Filtering and UV
  • Application: General laboratory analysis
  • Intended Use: Water purification
  • Instructions for Use: This item provides water filtered through 0.22 μm sterilizing-grade membranes and exposed to bactericidal UV lamp. Refer to system equipment user guide section "Using the System" (available on USB key in the system box)
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
  • 230 V systems are required for Europe, Africa and Middle East regions, and certain LATAM and APAC countries
  • 120 V systems are required for North America, Taiwan, and certain LATAM countries
  • 110 V systems are required for Japan

Legal Information

E.R.A. is a registered trademark of Merck KGaA, Darmstadt, Germany
ELIX is a registered trademark of Merck KGaA, Darmstadt, Germany
Milli-Q is a registered trademark of Merck KGaA, Darmstadt, Germany
MyMilli-Q is a trademark of Merck KGaA, Darmstadt, Germany
PROGARD is a registered trademark of Merck KGaA, Darmstadt, Germany

시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

문서

Explore how high-quality water is essential for accurate clinical chemistry assays and complying with norms and guidelines (e.g. CLSI).

Discover the importance of water quality in microbiology and its impact on reliable and reproducible results in culture media preparation. Learn about the EN ISO 11133 standard, lab water solutions, and purification technologies recommended for microbiological testing.

관련 콘텐츠

How consistent is your lab’s water quality? Variations in purified water quality may be impacting your lab’s analysis and overall efficiency of operations. See how Milli-Q® lab water systems deliver confidence in consistency.

Milli-Q® HX 7000 SD series purifies, stores, and distributes type 2 pure water efficiently in a compact format.

실험실의 정제수 수질이 얼마나 일정한가요? 정제수 수질의 변동은 실험실에서 진행되는 분석과 전체적인 운영 효율성에 영향을 미칠 수 있습니다. Milli-Q® 정제수 시스템이 일관성을 지키는 방법을 확인하십시오.

모두 보기

국제 무역 품목 번호

SKUGTIN
ZLXLSD5104004054839527258

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.