콘텐츠로 건너뛰기
Merck

SAMPLG001

Millex Samplicity® Filter

PTFE membrane, pore size 0.2 μm, diam. 25 mm, non-sterile, hydrophilic

동의어(들):

0.2 μm PTFE syringe filter, Millex-LG syringe filter, disposable syringe filter, syringe filter

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

크기 선택


제품정보 (DICE 배송 시 비용 별도)

UNSPSC Code:
41104922
NACRES:
NB.24
eCl@ss:
32031690
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의

제품 이름

Millex Samplicity® Filter, PTFE membrane, pore size 0.2 μm, diam. 25 mm, non-sterile, hydrophilic

material

PTFE membrane
high-density polyethylene

sterility

non-sterile

product line

Millex

feature

hydrophilic

manufacturer/tradename

Samplicity®

parameter

0.3 mL min. working volume

technique(s)

HPLC: suitable
analytical sample preparation: suitable

diam.

25 mm

volume

1.7 mL

pore size

0.2 μm pore size

fitting

inlet funnel (Easy loading)
outlet tip (for smooth transfer to HPLC vials)

shipped in

ambient

Application

To be used with the Samplicity Filtration System. Powered by vacuum, the system takes minimal manual effort to filter 1 to 8 samples into standard HPLC vials in seconds, with higher recovery than syringe filters provide.

Features and Benefits

For general laboratory use only

General description

Filter Code: LG
SAMP2LGNB replaces SAMPLG001

Overview of Millex Samplicity® Filters for the Samplicity® G2 System

  • Samplicity® G2 Filtration System enables vacuum driven filtration of up to 8 samples as once, directly into HPLC vials
  • Filtration for HPLC sample prep without syringes
  • Millex Samplicity® Filters provide integrated funnels and filters for easiest sample loading

Packaging

non sterile

Legal Information

MILLEX SAMPLICITY is a registered trademark of Merck KGaA, Darmstadt, Germany
Millex is a trademark of Merck KGaA, Darmstadt, Germany
SAMPLICITY is a registered trademark of Merck KGaA, Darmstadt, Germany

시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

관련 콘텐츠

The Samplicity® filtration system was developed to filter up to 8 samples directly into standard HPLC vials using vacuum-based filtration. The samples can then be used in downstream HPLC analysis. Given the high sensitivity of high performance liquid chromatography (HPLC) and ultra-high pressure liquid chromatography (UHPLC) analyses, it is critical to ensure that the filtered sample is not contaminated with extractables. This application note reports the results of tests for extractables from Millex Samplicity® LCR (0.45 μm hydrophilic PTFE) and LG (0.20 μm hydrophilic PTFE) filters using three commonly used HPLC detectors. The detectors used were an ultraviolet/visible (UV-Vis) spectrophotometer, a mass spectrometer and a fluorescence detector.

"Liquid chromatography mass spectrometry (LC-MS) and gas chromatography mass spectrometry (GC-MS) are being increasingly used in analysis of samples, not only in the biotechnology and pharmaceutical industries, but also more generally in the analysis, identification and quantitation of complex samples containing low levels of analytes. The advantages of LC-MS or GC-MS over other analytical techniques include high sensitivityand specificity for analyte detection and quantitation."

Because of its high sensitivity and extreme versatility, mass spectrometry has become a popular technique for identifying and quantifying molecules within complex mixtures, in diverse research areas that range from systems biology and proteomics to environmental analysis. Successful mass spectrometry requires extremely areful sample preparation, in order to avoid complexity of the mixtures being analyzed. EMD Millipore supports researchers using mass spectrometry with tools or multiple steps of the workflow, including purification, clarification, and analysis.

모두 보기

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.