콘텐츠로 건너뛰기
Merck

1.11136

Iron Test Kit, colorimetric

0.1-50 mg/L (Fe), MQuant®

동의어(들):

Iron Visual Test Kit

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

크기 선택


제품정보 (DICE 배송 시 비용 별도)

UNSPSC Code:
41116116
NACRES:
NA.24
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의

제품 이름

Iron Test, colorimetric, 0.1-50 mg/L (Fe), for use with MCOLORTEST®

specific analyte(s)

iron

measuring range

0.1-50 mg/L (Fe)

compatibility

for use with MCOLORTEST®

detection method

colorimetric

storage temp.

15-25°C

Quality Level

Legal Information

MQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany
MCOLORTEST is a registered trademark of Merck KGaA, Darmstadt, Germany

General description

Method: colorimetric with color-matching vessel 0.1 - 0.3 - 0.5 - 1.0 - 2.5 - 5.0 - 7.5 - 12.5 - 25 - 50 mg/l Fe MQuant®
The MQuant® Iron test (formally MColortest®) measures bivalent and trivalent iron in its dissolved form and also fresh colloidal e.g. in
  • Groundwater and surface water
  • Waters from aquaculture
  • Drinking water and mineral water
  • Industrial water
  • Wastewater and percolating water
  • Boiler and boiler feed water, cooling water
  • Food (e. g. wine) after appropriate sample pretreatment
This test is not suited for seawater.
We also recommend this as a pretest for the oxygen determination with MQuant® Oxygen 1.11107 to check for iron interferences in the sample.

This test evaluates the color reaction based on the transmitted light method. So even turbid and colored water samples can be analyzed without further preparation. The color matching vessel is made of very durable, lightfast plastic, thus suitable for industrial areas and wet environments.

Method
All iron ions are reduced to iron(II) ions by hydroxylammonium chloride. In a buffered medium these react with 2,2′-bipyridine to form a red complex. The iron concentration is measured semiquantitatively by visual comparison of the color of the measurement solution with the color zones of a color matching vessel.
Without the addition of hydroxylammonium chloride (reagent Fe-1), the test measures only iron(II). so a differentialtion is possible.

Using the refill pack 1.08023 containing all the reagents, the original test kit can be used for a very long time, making this a particularly economical and ecological system. 
The test measures bivalent and trivalent iron in its dissolved form and also fresh colloidal iron(III)hydroxide in e.g. groundwater and surface water, drinking water, industrial water and wastewater, whereas a differentiation between iron(II) and iron(III) is possible.

signalword

Warning

Hazard Classifications

Aquatic Chronic 3 - Carc. 2 - Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2 - Skin Sens. 1

저장 등급

8B - Non-combustible, corrosive hazardous materials

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

국제 무역 품목 번호

SKUGTIN
1.11136.000104022536130460

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.