Millipore Sigma Vibrant Logo

109701 Cyanide Test

109701
가격 및 재고 조회

개요

Replacement Information

가격 및 재고여부

카탈로그 번호 재고 정보패킹 포장 단위 가격(VAT 별도) 수량
1.09701.0001
재고 정보 검색...
현재 재고 없음
현재 재고 없음
예상 출고 가능일 
단종품
제한된 수량 가능
재고여부 확인
    Remaining: will advise
      Remaining: will advise
      추천사항
      고객 서비스로 문의
      Contact Customer Service

      Fibre case 100 tests
      가격 검색...
      가격을 검색할 수 없습니다
      Minimum Quantity needs to be mulitiple of
      Maximum Quantity is
      가격 문의 추가 정보
      ()이 할인됨
       
      가격 문의
      Description
      Catalogue Number109701
      OverviewThe method corresponds to DIN 38405-13 and is analogous to ISO 6703, EPA 335.2, APHA 4500-CN- E, and ASTM D2036-09 D.

      This Spectroquant® Cyanide Reagent Test allows the accurate quantification of the free and readily liberated cyanide content in aqueous samples.

      Method applied: Cyanide ions react with a chlorinating agent to form cyanogen chloride. In a follow-up reaction with 1,3-dimethylbarbituric acid in the presence of pyridine a violet dye (König reaction) is formed which is determined photometrically (only free cyanide. For readily liberated cyanide samples must be decomposed by digestion).

      The Spectroquant® Reagent Test Kits contain highly stable, ready-to-use reagent mixtures to perform the analysis according to the procedure described in the accompanying instruction leaflet.

      All our Cell and Reagent Test Kits are equipped with the unique Live ID which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.
      References
      Product Information
      HS Code3822 19 90
      Quality LevelMQ100
      Applications
      Biological Information
      Physicochemical Information
      Dimensions
      Materials Information
      Toxicological Information
      Safety Information according to GHS
      Hazard Pictogram(s) Hazard Pictogram(s)
      Hazard Pictogram(s)
      Hazard Statement(s)H290: May be corrosive to metals.
      H314: Causes severe skin burns and eye damage.
      H335: May cause respiratory irritation.
      H412: Harmful to aquatic life with long lasting effects.
      Precautionary Statement(s)P234: Keep only in original packaging.
      P261: Avoid breathing mist or vapours.
      P273: Avoid release to the environment.
      P280: Wear protective gloves/ protective clothing/ eye protection/ face protection/ hearing protection.
      P303 + P361 + P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.
      P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
      Signal WordDanger
      Storage class8A Combustible, corrosive hazardous materials
      WGKWGK 2 obviously hazardous to water
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      StorageStore at +15°C to +25°C.
      Packaging Information
      Transport Information
      Declaration (railroad and road) ADR, RIDUN 3316 Chemie-Testsatz, 9, II
      Declaration (transport by air) IATA-DGRUN 3316 CHEMICAL KIT, 9, II
      Declaration (transport by sea) IMDG-CodeUN 3316 CHEMICAL KIT, 9, II
      Supplemental Information
      Specifications
      Global Trade Item Number
      카탈로그 번호 GTIN
      1.09701.0001 04022536638645

      Documentation

      Cyanide Test MSDS

      타이틀

      물질안전보건자료(MSDS) 

      Cyanide Test Certificates of Analysis

      제품 번호 패킹스펙로트(lot) 번호
      1.09701.0001 Fibre casePDF 사양 문건

      Certificates

      Title
      109701 - Certificate of Quality - Spectroquant Cyanide Test / Cyanid-Test / Test Cianuros

      Technical Info

      Title
      Programming data for Spectrophotometer and Spectroquant Test Kits

      Data Sheet

      Title
      Data Sheet (CoQ) - 1.09701

      User Guides

      Title
      Analytical Procedures and Appendices Spectroquant Prove 300
      Analytical Procedures and Appendices Spectroquant®Prove 600
      Manual Spectroquant Multy - Operating manual
      Manual Spectroquant®Prove Connect to Dashboard - English
      Manual Spectroquant®Prove Connect to LIMS - English
      Quick Guide Spectroquant Photometer NOVA 60A (EN, DE, FR, ES, IT)
      User Guide (IFU) - 1.09701

      Instructions for Use

      Title
      Spectroquant®Prove Quick Guide - Chinese Simplified

      관련 제품 및 어플리케이션

      Alternative Products

      카탈로그 번호 설명  
      114561 Cyanide Cell Test 가격 및 재고 조회

      Related Products

      카탈로그 번호 설명  
      114561 Cyanide Cell Test 가격 및 재고 조회

      Accessories (Primary)

      Accessories (Secondary)

      카탈로그 번호 설명  
      173502 Semi-microcells 50 mm 가격 및 재고 조회

      관련 제품: Application Facete

      관련 제품: Brand Facete

      카테고리

      Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Drinking Water > Cyanide
      Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Waste Water > Cyanide
      Analytics and Sample Preparation > Test Kits and Photometric Methods > Base Parameters from A to Z > Cyanide
      Analytics and Sample Preparation > Test Kits and Photometric Methods > Instrumental Test Systems for Quantitative Analyses > Photometric Measurements, Spectroquant® System > Spectroquant® Tests
      Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Environment > Cyanide
      Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Electroplating > Cyanide
      Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Groundwater, Surface Water > Cyanide
      Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Disposal Drainage Water > Cyanide
      Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Mineral Water > Cyanide