콘텐츠로 건너뛰기
Merck

SCT277

BioTracker Red pH-Independent Autophagy Live Cell Probe

Human

동의어(들):

autophagosome live cell probe, red AP live cell probe, red autophagosome probe, red autophagy probe

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

크기 선택


제품정보 (DICE 배송 시 비용 별도)

UNSPSC Code:
41106514
NACRES:
NA.47
Biological source:
human
Manufacturer/tradename:
Millipore
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의

제품 이름

BioTracker Red pH-Independent Autophagy Live Cell Probe,

biological source

human

packaging

vial of 5 nmol

manufacturer/tradename

Millipore

technique(s)

cell culture | stem cell: suitable, flow cytometry: suitable

shipped in

2-8°C

storage temp.

2-8°C

Quality Level

General description

BioTracker Red pH-Independent Autophagy Live Cell Probe detects autophagosomes and autolysosomes. The presumptive mechanism involves incorporation of the probe via structural features into the autophagosome during double-membrane formation. Upon incorporation, the probe emits fluorescence under hydrophobic conditions. The utility of the probe is conferred by molecular properties that include cell permeability, does not require transfection, and enables live cell detection with fluorescence microscopy or other fluorescence capture instruments.
The small fluorescent molecule SCT277 is used to detect autophagosomes and autolysosomes. The presumed mechanism is that the dye is incorporated into the autophagosome during double-membrane formation via structural features, and then emits fluorescence under hydrophobic conditions. The probe emits in the far red range.SPECTRAL CHARACTERISTICS: Excitation λ: 530 nmEmission λ: 720 nm

Features and Benefits

Fluorescence microscopyFlow cytometry

Preparation Note

Store at -20 °C, protected from light.

Other Notes

SCT277 detects autophagosomes and autolysosomes by the likely mechanism of incorporation into the autophagosome during double membrane formation, and emits red fluorescence under hydrophobic conditions. SCT277 is cell permeable, does not require transfection, and enables live cell imaging with fluorescence microscopy and quantitative assay by flow cytometry.Add 50 uL DMSO to tube of SCT277 (5 nmol) and pipet to dissolve to make a 0.1 mM stock solution. Dilute with culture medium to 0.1 - 0.5 uM to make working solution.

Legal Information

BioTracker is a trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

저장 등급

11 - Combustible Solids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

국제 무역 품목 번호

SKUGTIN
SCT27704065269218579

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.