콘텐츠로 건너뛰기
Merck

SCC275

721.221 Human HLA Negative B-Lymphoblastoid Cell Line

Human

동의어(들):

721.221 Cell Line, B-Lymphoblastoid Cells, Human HLA Negative Cells

조직 및 계약 가격을 보려면 를 클릭합니다.

크기 선택

보기 변경

제품정보 (DICE 배송 시 비용 별도)

UNSPSC Code:
41106514
NACRES:
NA.45
Biological source:
human
Growth mode:
N/A
Manufacturer/tradename:
Millipore
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의


제품 이름

721.221 Human HLA Negative B-Lymphoblastoid Cell Line,

biological source

human

packaging

vial of >1X10⁶ cells

manufacturer/tradename

Millipore

growth mode

N/A

technique(s)

cell culture | mammalian: suitable

shipped in

dry ice

storage temp.

−196°C

Application

  • 721.221 Human HLA negative B-lymphoblastoid cells are verified to be of human origin and negative for mouse, rat, Chinese hamster, Golden Syrian hamster, and non-human primate interspecies contamination, as assessed by a Contamination Clear panel by Charles River Animal Diagnostic Services
  • Cells tested negative for infectious diseases against a Human Essential CLEAR panel by Charles River Animal Diagnostic Services.
  • Cells tested negative for mycoplasma.

The human leukocyte antigen (HLA) gene complex encodes the major histocompatibility complex (MHC) proteins, key regulators of the human immune system. MHC proteins carry antigenic determinants for cell-surface recognition by T cells, and allow for immune autorecognition.1 The diversity of antigens provides a challenge for parsing individual T-cell activators and specific immune responses, and the ability to manipulate specific determinants is a paramount factor for understanding autoimmune diseases that arise from MHC dysfunction.
The 721.221 human HLA-negative B cell lymphoblastoid cell line is a well-established model for immune activation and HLA expression. The absence of class I HLA expression in 721.221 cells allows for functional analysis of individual class I antigens via transformation with individual HLA genes.2 HLA genes are ectopically expressed at quantitatively normal levels in 721.21 cells.2 721.221 cells express the B-cell marker CD19 4 and several NK activator ligands including CD48, CD80, and CD86. 5 The unique characteristics of the 721.221 cell line make it a highly versatile system for immunology research.

Source
The 721.221 cell line was derived from 721 lymphoblastoid cell line exposed to gamma radiation, inducing null mutations in endogenous HLA-A, B, and C class I antigen genes.

References
1. Simpson E. Immunol Suppl. 1988; 1:27-30.
2. Shimizu Y, DeMars R. J Immunol. 1989; 142(9):3320-3328.
3. Lisovsky I, Isitman G, Bruneau J, Bernard NF. J Leukoc Biol 2015; 97(4):761-767.
4. DeBell KE, Simhadri VR, Mariano JL, Borrego F. BMC Immunol 2012; 13:23.
5. Tremblay-McLean A, Coenraads S, Kiani Z, Dupuy FP, Bernard NF. BMC Immunol 2019; 20(1):8

Features and Benefits

The unique characteristics of the 721.221 cell line make it a highly versatile system for immunology research.

Preparation Note

Store in liquid nitrogen. The cells can be cultured for at least 10 passages after initial thawing without significantly affecting the cell marker expression and functionality.

Other Notes

Subject to local law, this product is intended to be sold for internal in vitro research use only subject to terms and conditions found here: www.sigmaaldrich.com/restrictedcelluse. This product may not be: re-engineered or copied; used to make derivatives, modifications or functional equivalents; used to obtain patents or other IP claiming use of the product; used to develop, test, or manufacturer a commercial product; used as a component in a commercial product; resold or licensed; used in any clinical applications or trials; or used in humans. A license or limited commercial use agreement is required for use by any for-profit entity, use in services, and use in sponsored academic research. For information regarding any such use, please contact licensing@milliporesigma.com.

Disclaimer

RESEARCH USE ONLY. This product is regulated in France when intended to be used for scientific purposes, including for import and export activities (Article L 1211-1 paragraph 2 of the Public Health Code). The purchaser (i.e. enduser) is required to obtain an import authorization from the France Ministry of Research referred in the Article L1245-5-1 II. of Public Health Code. By ordering this product, you are confirming that you have obtained the proper import authorization.
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.


저장 등급

10 - Combustible liquids

wgk

WGK 2

flash_point_f

Not applicable

flash_point_c

Not applicable



시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문