Millipore Sigma Vibrant Logo

KGEPG1TTT1 Opticap® XLT 10 Millipore Express® SHF Gamma Compatible 0.2 µm 1-1/2 in. TC

View Products on Sigmaaldrich.com
KGEPG1TTT1
1  Double Easy-Open bag
Retrieving price...
Price could not be retrieved
Minimum Quantity is a multiple of
Maximum Quantity is
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Limited Availability
Limited Availability
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

       

      Contact Customer Service

      Overview

      Replacement Information
      Description
      Catalogue NumberKGEPG1TTT1
      Trade Name
      • Millipore Express®
      DescriptionOpticap® XLT 10 Millipore Express® SHF Gamma Compatible 0.2 µm 1-1/2 in. TC
      References
      Product Information
      Device ConfigurationCapsule
      Connections, Inlet/Outlet38 mm (1-1/2 in.) Sanitary Flange
      Connections, Vent/Drain1/4 in. Hose Barb with double O-ring seal
      Housing MaterialPolypropylene (PP)
      Maximum Differential Pressure, bar (psid)Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
      Maximum Inlet Pressure, bar (psi)6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
      European Pressure Equipment DirectiveEMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      T-line/Gauge PortT-line
      Quality LevelMQ400
      Applications
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaMillipore Express® SHF
      SterilityNon-sterile, Gamma compatible
      SterilizationGamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
      Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
      WettabilityHydrophilic
      Physicochemical Information
      Pore Size0.2 µm
      Inlet ConnectionSanitary Flange
      Outlet ConnectionSanitary Flange
      Air Diffusion at 23 °C≤32.7 mL/min @ 2.8 bar (40 psig) in water
      Bubble Point at 23 °C≥4000 mbar (58 psig) air with water
      Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
      Maximum Inlet Pressure (psig)80 psig
      Maximum Differential Pressure80 psi (5.5 bar) continuous
      100 psi (6.9 bar) intermittent
      Maximum Inlet Temperature25 °C
      Non-Fiber ReleasingThis product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      TOC/ConductivityAfter sterilization and a controlled water flush of 11 L, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 µS/cm per USP <645> at 25 °C.
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Cartridge Nominal Length10 in. (25 cm)
      Length37.6 cm (14.8 in.)
      Diameter10.7 cm (4.2 in.)
      Filtration Area0.57 m²
      Inlet to Outlet Width15.2 cm (6.0 in.)
      Device Size10 in.
      Inlet Connection Diameter1-1/2 in.
      Outlet Connection Diameter1-1/2 in.
      Materials Information
      Chemistry
      • Polyethersulfone (PES)
      Device Material
      • Gamma stable polypropylene/Polysulfone
      Seal MaterialSilicone (SI)
      Support MaterialPolyester
      Vent Cap MaterialPolypropylene (PP)
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size1
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Specifications
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥1.5 L
      Global Trade Item Number
      Catalogue Number GTIN
      KGEPG1TTT1 04053252565854

      Documentation

      Material Qualification Dossier

      TitleVersion
      1.0

      Quality Management Dossier (Open Access)

      Title

      Operational Excellence Dossier

      Title

      Certificates of Quality

      Title
      OPTICAP XL 150 Capsule Millipore Express SHF membrane C1SB86033
      OPTICAP XLT 10 Capsule Millipore Express SHF membrane C3EB10386
      OPTICAP XLT 10 Capsule Millipore Express SHF membrane C3KB53483
      OPTICAP XLT 10 Capsule Millipore Express SHF membrane C3PB62843
      Opticap XL 10 Capsule Millipore Express SHF Membrane C8CA29048
      Opticap XLT 10 Capsule Millipore Express SHF Membrane C7HA18392
      Opticap XLT 10 Capsule Millipore Express SHF Membrane C0CB28673
      Opticap XLT 10 Capsule Millipore Express SHF Membrane C0EB39252
      Opticap XLT 10 Capsule Millipore Express SHF Membrane C0KB40794
      Opticap XLT 10 Capsule Millipore Express SHF Membrane C0NB03365

      Technical Info

      Title
      1X PBS (Phosphate Buffered Saline) Buffer Mixing Optimization
      Autoclaving Guidelines for Opticap® XL and XLT Disposable Capsule Filters
      Extended bacterial retention testing of Millipore Express® 0.2 μm filters in a continuous flow system
      Scalable Process Filtration with Millipore Express® SHF 0.2 μm Filters
      Scalable Process Filtration with Opticap® XL 150, 300 and 600 Capsules with Millipore Express® Membranes
      Simplified, efficient sizing of sterilizing-grade normal flow filters for buffer solutions

      User Guides

      Title
      Opticap® XL Capsules and Opticap® XLT Capsules
      User Guide - Filters with Millipore Express®Membrane