Chromolith® HR RP-18 Endcapped
|
Speed, Packing Shape & Reproducibility
Chromolith® HighResolution RP-18 endcapped columns are the ultimate choice for faster chromatographic separations. The short monolithic structure of these HPLC columns delivers ultra-fast results at low back pressure for both isocratic and gradient applications. This allows high sample throughput and fast column re-equilibration between analyses, saving time and costs in your chromatographic analyses.
Chromolith® Performance and Chromolith® HighResolution in Comparison
Chromolith® HighResolution RP-18e, 100-4.6 mm
Solvents |
A: ACN B: 0.02 mM phosphate buffer pH 2.5 |
Gradient |
0.0 min 20% A |
Flow rate |
3.5 ml/min |
Column pressure |
49-71 bar |
Temperature |
ambient |
LCF system |
LaChrom L7000 |
Detection |
UV 230 nm |
Vol. detector cell |
16 µl |
Inj. volume |
Silica monolithic: 40 bar |
Sample |
1. Atenolol 2. Pindolol 3. Metoprolol 4. Bisoprolol 5. Labetalol 6. Propanolol |
|
Chromolith® HighResolution RP-18e, 25-4.6mm
Solvents |
60% ACN / 40% water isocratic |
Gradient |
0.3 min 40% A |
Flow rate |
2.0 ml/min |
Column pressure |
15 bar |
Temperature |
ambient |
LCF system |
|
Detection |
UV 254 nm |
Vol. detector cell |
16 µl |
Inj. volume |
Core-shell: 100 bar |
Sample |
1. Thiourea 2. Biphenyl-2-ol 3. Progesterone 4. Hexanophenone 5. Anthracene |
|
Improved Peak Shape of Basic Compounds
Chromolith® HighResolution RP-18 endcapped stationary phases enable the elution of basic compounds with excellent peak shape and no tailing.
See Details
Mobile phase |
A: ACN, B: 20 nM NaH2PO4 buffer pH 7.6 |
Gradient |
0.0 min 20% A, 0.5 min 45% A |
Flow rate |
2.0 ml/min |
Column pressure |
63-69 bar |
Temperature |
ambient |
Detection |
UV 254 nm |
Temperature |
ambient |
Vol. detector cell |
16 µl |
Inj. volume |
10 µL |
Sample |
1. Caffeine 2. Aniline 3. N-Methylaniline 4. 2-Ethylaniline 5. 4-Nitranisole 6. N,N-Dimethylaniline |
|
Excellent Batch-to-Batch Reproducibility
Chromolith HighResolution RP-18e, 100-4.6 mm
The batch-to-batch reproducibility of Chromolith® HPLC columns is strictly monitored and fulfills the requirements of QA and QC laboratories.
See Details
Mobile phase |
A: Acetonitrile + 0.1% TFA B: Water + 0.1% TFA |
Gradient |
2.0 min 0% A, 10.0 min 30% A |
Flow rate |
1.0 ml/min |
Temperature |
25°C |
Detection |
UV 210 nm |
Inj. volume |
2 µl |
Sample |
1. Norepinephrine 2. Octopamine 3. Epinephrine tartrate 4. Dopamine 5. DOPA 6. Norephedrine 7. Ephedrine 8. N-Methylephedrine |
|
Features and Benefits
- Column performance corresponds to sub 3 µm particle-packed columns and is at least 50% higher compared to standard Chromolith® columns
- Back pressure at least half that of particulate columns
- Minimum 30% longer column lifetime compared with particle-packed columns
Products
Chromolith® HighResolution RP-18e
|
Ordering Number
|
100 mm |
152022 |
50 mm |
152021 |
25 mm |
152020 |
5 mm Guard Columns (3 pieces) |
152025 |