Millipore Sigma Vibrant Logo

Viresolve NFP カートリッジフィルター

Viresolve NFP filters with Viresolve NFP (Normal Flow Parvovirus) membranes clear parvovirus from recombinant or human plasma sources, without compromising flow rates.

概要

仕様

ご注文情報

Documentation

参考資料

参考資料の概要
Validation of Virus Filtration
Carter, Jeff and Herb Lutz
BioProcess International January 2003: 52-62  2003

Removal of prion challenge from an immune globulin preparation by use of a size-exclusion filter
VAN HOLTEN Robert W; AUTENRIETH Stephen; BOOSE Jeri Ann; HSIEH W T; DOLAN Sherri
Transfusion : (Philadelphia, PA), 2002, 42 (8) 999-1004  2002

An overview of viral filtration in biopharmaceutical manufacturing
Jeffrey Carter and Herbert Lutz, Millipore Corporation, Bedford, MA, USA; European Journal of Parenteral Sciences 2002; 7(3): 72–78 © 2002 Parenteral Society
European Journal of Parenteral Sciences 2002; 7(3): 72–78 © 2002 Parenteral Society  2002

Development and Qualification of a Novel Virus Removal Filter for Cell Culture Applications
Shengjiang Liu, Mark Carroll, Raquel Iverson, Christine Valera, Joann Vennari, Kimberly Turco, Robert Piper, Robert Kiss, Herbert Lutz
Biotechnology Progress  2000

Filtration and the Removal of Viruses from Biopharmaceuticals
Levy, Richard V., Michael W. Phillips, and Herbert Lutz
Chapter 20 in Filtration in the Biopharmaceutical Industry. New York: Marcel Dekker, Inc., 1998.  1998

A Validatible Porosimetric Technique for Verifying the Integrity of Virus-Retentive Membranes
Michael W. Phillips and Anthony J. DiLeo Advanced Separations Research Department, Millipore Corporation, 80 Ashby Road, Bedford MA 0 1 730, U.S.A.
Biologicals. 1996 Sep;24(3):243-53.  1996

High Resolution Removal of Virus From Protein Solutions Using A Membrane of Unique Structure
DiLeo, Anthony J., Anthony E. Allegrezza, and Stuart E. Builder
Bio/Technology (February 1992): 182-188; RP002  1992

FAQ(よくある質問と回答)

質問回答
What is the hold-up volume of an Optiscale 25 NFP ?Millipore does not have a published specification for the hold up volume for an Optiscale 25 NFP capsule. The approximate hold up volume is 300 ul.

関連製品&アプリケーション

製品ファミリー

関連製品: Application Facete

関連製品: Brand Facete

カテゴリー

Biopharmaceutical Manufacturing > Downstream Processing > Virus Safety > Virus Filtration > Viresolve Pro & Pro+ > Viresolve NFP