Custom Premix Selecting "Custom Premix" option means that all of the beads you have chosen will be premixed in manufacturing before the kit is sent to you.
Catalogue Number
Ordering Description
Qty/Pack
List
この品目はお気に入りに追加されました。
動物種
パネルタイプ
選択したキット
数量
カタログ番号
注文内容
Qty/Pk
価格
96-Well Plate
数量
カタログ番号
注文内容
Qty/Pk
価格
その他の試薬を追加 (MAPmatesとともに使用するにはバッファーおよび検出キットが必要です)
数量
カタログ番号
注文内容
Qty/Pk
価格
48-602MAG
Buffer Detection Kit for Magnetic Beads
1 Kit
Space Saver Option(チェックを入れると箱詰めから袋詰めに変更となりますのでご注意ください) Customers purchasing multiple kits may choose to save storage space by eliminating the kit packaging and receiving their multiplex assay components in plastic bags for more compact storage.
Ideal for coupling enzymes to antibodies. Contains a cyclohexane bridge, which gives extra stability to the maleimide group. Both enzyme activity and antibody specificity are preserved after coupling.
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Wear suitable protective clothing.
Product Usage Statements
Storage and Shipping Information
Ship Code
Ambient Temperature Only
Toxicity
Irritant
Storage
+2°C to +8°C
Do not freeze
Ok to freeze
Special Instructions
Following each use, purge the original vial with inert gas and refrigerate (4°C). Unstable in aqueous solution; reconstitute just prior to use. Alternatively, the solid SMCC can be added directly to the sample to minimize hydrolysis. Hydrolysis is more pronounced in dilute protein solutions and can, therefore, be minimized by using more concentrated protein solutions (>5 mg/ml). For storage of stock solutions, reconstitute in anhydrous DMSO.
D’Souza, S.E., et al. 1988. J. Biol. Chem.263, 3943.
データシート
Note that this data sheet is not lot-specific and is representative of the current specifications for this product. Please consult the vial label and the certificate of analysis for information on specific lots. Also note that shipping conditions may differ from storage conditions.
A water-soluble derivative of SMCC. Ideal for coupling enzymes to antibodies. Contains a cyclohexane bridge, which gives extra stability to the maleimide group. Both enzyme activity and antibody specificity are preserved after coupling. Water-soluble cross-linking reagents help to avoid the use of organic solvents such as dimethylformamide (DMF) and dimethylsulfoxide (DMSO) when preparing bioconjugates.
Form
Off-white solid
CAS number
92921-24-9
Chemical formula
C₁₆H₁₇N₂O₉S · Na
Structure formula
Purity
≥94% by HPLC
Solubility
H₂O (2-5 mg/ml)
Storage
+2°C to +8°C
Do Not Freeze
Ok to freeze
Special Instructions
Following each use, purge the original vial with inert gas and refrigerate (4°C). Unstable in aqueous solution; reconstitute just prior to use. Alternatively, the solid SMCC can be added directly to the sample to minimize hydrolysis. Hydrolysis is more pronounced in dilute protein solutions and can, therefore, be minimized by using more concentrated protein solutions (>5 mg/ml). For storage of stock solutions, reconstitute in anhydrous DMSO.
Toxicity
Irritant
References