Millipore Sigma Vibrant Logo

KPGEG2TTT1 Opticap® XLT 20 Millipore Express® PHF Gamma Compatible 0.2 µm 1-1/2 in. TC

View This Product on Sigma-Aldrich
KPGEG2TTT1
1  Double Easy-Open bag
価格を検索中…
価格が見つかりません
Minimum Quantity needs to be mulitiple of
Maximum Quantity is
弊社照会 詳細を表示 
値引
()
 
弊社照会
現在国内在庫なし
現在国内在庫なし
現在国内在庫有り 
販売中止
在庫僅少
現在国内在庫あり
    Remaining : Will advise
      Remaining : Will advise
      注文対象外
      お問合せください
      Contact Customer Service

       

      お問合せください

      概要

      Replacement Information
      Description
      Catalogue NumberKPGEG2TTT1
      Trade Name
      • Millipore Express®
      DescriptionOpticap® XLT 20 Millipore Express® PHF Gamma Compatible 0.2 µm 1-1/2 in. TC
      References
      Product Information
      Device ConfigurationCapsule
      Connections, Inlet/Outlet38 mm (1-1/2 in.) Sanitary Flange
      Connections, Vent/Drain1/4 in. Hose Barb with double O-ring seal
      Housing MaterialPolypropylene (PP)
      Maximum Inlet Pressure, bar (psi)5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
      European Pressure Equipment DirectiveEMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      T-line/Gauge PortT-line
      Quality LevelMQ400
      Applications
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaMillipore Express® PHF
      SterilityGamma
      SterilizationGamma compatible to 40 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
      Bacterial RetentionSamples of membrane used in this filter were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
      WettabilityHydrophilic
      Physicochemical Information
      Pore Size0.2 µm
      Inlet ConnectionSanitary Flange
      Outlet ConnectionSanitary Flange
      Air Diffusion at 23 °C≤65.5 mL/min @ 2.8 bar (40 psig) in water
      Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
      Maximum Inlet Pressure (psig)80 psig
      Maximum Differential Pressure5500 mbar (80 psi) @ 25 °C; 1000 bar (15 psi) @ 80 °C
      Maximum Inlet Temperature25 °C
      Non-Fiber ReleasingThis product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      TOC/ConductivityAfter sterilization and a controlled water flush of 22 L, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 µS/cm per USP <645> at 25 °C.
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Cartridge Nominal Length20 in. (50 cm)
      Length62.5 cm (24.6 in.)
      Diameter10.7 cm (4.2 in.)
      Filtration Area1.14 m²
      Inlet to Outlet Width15.2 cm (6.0 in.)
      Device Size20 in.
      Inlet Connection Diameter1-1/2 in.
      Outlet Connection Diameter1-1/2 in.
      Materials Information
      Chemistry
      • Polyethersulfone (PES)
      Device Material
      • Gamma stable polypropylene/Polysulfone
      Seal MaterialSilicone (SI)
      Support MaterialPolyester
      Vent Cap MaterialPolypropylene (PP)
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size1
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Specifications
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
      Global Trade Item Number
      カタログ番号 GTIN
      KPGEG2TTT1 04055977295306

      Documentation

      品質証明書

      タイトル
      Opticap XLT 20 Capsule Millipore Express PHF Membrane C1AB47768
      Opticap XLT 20 Capsule Millipore Express PHF Membrane - C8KA86381
      Opticap XLT 20 Capsule Millipore Express PHF Membrane C1EB80786
      Opticap XLT 20 Capsule Millipore Express PHF Membrane C3KB46472
      Opticap XLT 20 Capsule Millipore Express PHF Membrane C3SB66033
      Opticap XLT 20 Capsule Millipore Express PHF Membrane C7CA64624
      Opticap XLT 20 Capsule Millipore Express PHF Membrane C9EA30029
      Opticap XLT 20 Capsule Millipore Express PHF Membrane- C4BB87983

      関連製品&アプリケーション

      製品ファミリー

      関連製品: Brand Facete

      カテゴリー

      Biopharmaceutical Manufacturing > Downstream Processing > Sterile Filtration > Sterile Liquid > Millipore Express®
      Biopharmaceutical Manufacturing > Upstream Processing > Multi-use Processing Systems > NovAseptic > Millipore Express