Quality Segment
material
316L stainless steel lock ring, 316L stainless steel welding flange, stainless steel bolt (A193 Gr B8M/A194 Gr B8M), stainless steel nut (A193 Gr B8M/A194 Gr B8M)
description
Manually polished; Ra ?1.6 μm (63 μin), connector type: flush mounted
parameter
-1 to -7 bar pressure, -80-200 °C temp. range
weight
2.0 kg4.41 lb
Application
The applied gasket (not included) may have different design temperature and/or pressure limits than the NovAseptic Connector. The weakest component in the assembled product determines the maximum design temperature and pressure limits.
Packaging
All open ends on the NovAseptic Connector are protected with plastic covers on delivery. The NovAseptic Connector is pre-assembled and packaged in a closed box.
Disclaimer
The NovAseptic Connector does comply for USA with the relevant requirements in ASME. The equipment has been calculated and evaluated of stress levels due to internal pressure in accordance with ASME VIII, Division 2, "Mandatory design based on stress analysis". The analysis has been calculated with assistance of FEM.
Still not finding the right product?
Explore all of our products under NovAseptic Connector, According to ASME, Tube Standard ASTM A270 (inch)
試験成績書(COA)