Millipore Sigma Vibrant Logo

MFVL06GH3 Non-sterilized Millipak® Final Fill 60 Filter Unit 0.1  µm 1/4  in. HB/HB

MFVL06GH3
3  Double Easy-Open bag
価格を検索中…
価格が見つかりません
Minimum Quantity needs to be mulitiple of
Maximum Quantity is
弊社照会 詳細を表示 
値引
()
 
弊社照会
現在国内在庫なし
現在国内在庫なし
現在国内在庫有り 
販売中止
在庫僅少
現在国内在庫あり
    Remaining : Will advise
      Remaining : Will advise
      注文対象外
      お問合せください
      Contact Customer Service

       

      お問合せください

      概要

      Replacement Information
      Description
      Catalogue NumberMFVL06GH3
      Trade Name
      • Millipak®
      DescriptionNon-sterilized Millipak® Final Fill 60 Filter Unit 0.1  µm 1/4  in. HB/HB
      References
      Product Information
      Device ConfigurationCapsule
      Connections, Inlet/Outlet6  mm (¼  in.) stepped hose barb inlet and outlet
      Maximum Differential Pressure, bar (psid)Foward:80 psi (5.5 bar) at 25 °C (0.1 µm, 0.22 µm, 0.45 µm, hydrophobic 0.22 µm); Reverse: 10 psi (0.7 bar) at 25 °C
      Maximum Inlet Pressure, bar (psi)80 psi (5.5 bar) at 25 °C
      Good Manufacturing PracticesThese products are manufactured in a facility which is certified to ISO® 9001:2015 Quality Management Systems.
      Quality LevelMQ400
      Applications
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains < 0.25 EU/mL per device as determined using the Limulus Amebocyte Lysate (LAL) test, meeting requirements of USP <85>, EP 2.6.14 and JP 4.01.
      MediaDurapore®
      Sterilitynon-sterilized
      SterilizationDevice integrity and retention was maintained after 3 autoclave cycles of 90 minutes at 126  °C. Devices can withstand a dose ≤ 40  kGy gamma exposure.
      Bacterial RetentionQuantitative retention of 107 CFU/cm2 Brevundimonas diminuta ATCC® 19146 per AST® F838 methodology.
      WettabilityHydrophilic
      Physicochemical Information
      Pore Size0.1 µm
      Inlet ConnectionStepped Hose Barb
      Outlet ConnectionStepped Hose Barb
      Bubble Point at 23 °C≥ 70 psi (4830 mbar) air with water
      Flow Rate0.51 L/min @ .69 bar ΔP
      Non-Fiber ReleasingThis product was manufactured with a Durapore® membrane which meets the criteria for a “non-fiber releasing” filter as defined in 21 CFR 210.3 (b)(6), validated based on large volume parenteral specifications as detailed in USP <788> Particulate Matter in Injections
      USP Bacterial EndotoxinsAqueous extraction contains < 0.25 EU/mL per device as determined using the Limulus Amebocyte Lysate (LAL) test, meeting requirements of USP <85>, EP 2.6.14 and JP 4.01.
      Dimensions
      Filtration Area300 cm²
      Process Volume60 L
      Inlet Connection Diameter1/4 in.
      Outlet Connection Diameter1/4 in.
      Materials Information
      Chemistry
      • Polyvinylidene Fluoride (PVDF)
      Device Material
      • Polysulfone
      Support MaterialPolysulfone
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size3
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Specifications
      Global Trade Item Number
      カタログ番号 GTIN
      MFVL06GH3 04054839378317

      Documentation

      Material Qualification Dossier

      タイトルバージョン
      1.0

      Operational Excellence Dossier

      Title

      Operational Excellence Dossier (Second Sterilization)

      Title

      品質証明書

      タイトル
      Millipak Final Fill Capsule Durapore Membrane C1DB73994

      技術情報

      タイトル
      Improved Product Recovery using Blow-down and Millipak®Final Fill Filters
      Integrity Test Troubleshooting - Beyond Rewet and Retest
      Reduce Contamination Risks and Simplify Filtration System Design and Operation

      データシート

      タイトル
      Durapore® Family Guide

      ユーザーガイド

      タイトル
      Wetting Instructions for Filter Units with Durapore Membrane

      関連製品&アプリケーション