Millipore Sigma Vibrant Logo

BCYT1-33K-PX15 MILLIPLEX® Bovine Cytokine/Chemokine Magnetic Bead Premixed 15-plex Panel 1 - Immunology Multiplex Assay

View This Product on Sigma-Aldrich
BCYT1-33K-PX15
96-well plate  96 well plate
価格を検索中…
価格が見つかりません
Minimum Quantity needs to be mulitiple of
Maximum Quantity is
弊社照会 詳細を表示 
値引
()
 
弊社照会
現在国内在庫なし
現在国内在庫なし
現在国内在庫有り 
販売中止
在庫僅少
現在国内在庫あり
    Remaining : Will advise
      Remaining : Will advise
      注文対象外
      お問合せください
      Contact Customer Service

       

      お問合せください

      概要

      Replacement Information

      主要スペック表

      Analytes AvailableSpecies ReactivityKey ApplicationsDetection Methods
      IFNγ IL-1α IL-1β IL-4 IL-6 IL-8 IL-10 IL-17A MIP-1α IL-36RA IP-10 MCP-1 MIP-1β TNFα VEGF-A BMplexLuminex xMAP
      Description
      Catalogue NumberBCYT1-33K-PX15
      Trade Name
      • MILLIPLEX
      DescriptionMILLIPLEX® Bovine Cytokine/Chemokine Magnetic Bead Premixed 15-plex Panel 1 - Immunology Multiplex Assay
      OverviewThe MILLIPLEX® Bovine Cytokine/Chemokine Magnetic Bead Premixed 15-plex Panel 1 is a 15-plex kit to be used for the simultaneous quantification of all of the following analytes in serum, plasma, and tissue culture supernatant samples: IFNγ, IL-1α, IL-1β, IL-4, IL-6, IL-8 (CXCL8), IL-10, IL-17A, IL-36RA (IL-1F5), IP-10 (CXCL10), MCP-1 (CCL2), MIP-1α (CCL3), MIP-1β (CCL4), TNFα, and VEGF-A.

      MILLIPLEX® offers the broadest selection of analytes across a wide range of disease states and species. Once the analytes of interest have been identified, you can rely on the quality that we build into each kit to produce results you can trust. In addition to the assay characteristics listed in the protocol, other performance criteria evaluated during the validation process include: cross-reactivity, dilution linearity, kit stability, and sample behavior (e.g. detectability and stability). Each panel and kit meets stringent manufacturing criteria to ensure batch-to-batch reproducibility.

      Each MILLIPLEX® panel and kit includes:
      - Quality controls (QCs) provided to qualify assay performance

      - Comparison of standard (calibrator) and QC lots to a reference lot to ensure lot-to-lot consistency

      - Optimized serum matrix to mimic native analyte environment

      - Detection antibody cocktails designed to yield consistent analyte profiles within panel


      The MILLIPLEX® Bovine Cytokine/Chemokine Magnetic Bead Panel 1 is part of the most versatile system available for cytokine and chemokine research. From our single to multiplex biomarker solutions, we partner with you to design, develop, analytically validate and build the most comprehensive library available for protein detection and quantitation.
      Background InformationInflammation and immune cell response are key to maintaining homeostasis. Inflammation plays a central role in the etiology of many immunologically related diseases, such as infectious disease, osteoarthritis and respiratory disease, as well as neurologic, metabolic and cardiovascular disease and even cancer. However, until now the ability to measure levels of cytokines and chemokines in bovine samples has been limited primarily to ELISAs. Researchers can now measure multiple inflammatory biomarkers simultaneously using our MILLIPLEX® Bovine Cytokine/Chemokine Panel 1, based on the Luminex® xMAP® technology.
      References
      Product Information
      Detection methodLuminex xMAP
      HS Code3002 15 90
      ConfigurationPremixed
      Precision, %
      • Inter-assay: <15
      • Intra-assay: <10
      Panel TypeMAGNETIC Cytokines/Chemokines
      Applications
      ApplicationThe Bovine Cytokine/Chemokine bead-based multiplex cytokine panel, using the Luminex xMAP technology, enables the simultaneous analysis of 15 cytokine and chemokine biomarkers in bovine serum, plasma and cell culture samples.
      Key Applications
      • Multiplexing
      Application Notes• This is an overnight incubation assay (or you may incubate at room temperature for 2 hours with shaking).
      • A maximum of 25 μL per well 1:2 diluted serum or plasma can be used. Tissue culture or other media may be run neat or appropriately diluted in control medium.
      • This kit may be used for the analysis of all the Bovine Cytokine/Chemokine Panel 1 analytes in serum, plasma or tissue/cell/tumor culture supernatant.
      Biological Information
      SpecificityCross-reactivity between the antibodies and any of the other analytes in this panel is non-detectable or negligible.
      Species Reactivity
      • Bovine
      Analytes Available
      • IFNγ
      • IL-1α
      • IL-1β
      • IL-4
      • IL-6
      • IL-8
      • IL-10
      • IL-17A
      • MIP-1α
      • IL-36RA
      • IP-10
      • MCP-1
      • MIP-1β
      • TNFα
      • VEGF-A
      Cross ReactivityCross-reactivity between the antibodies and any of the other analytes in this panel is non-detectable or negligible.
      Accuracy
      • IFNγ: 94%
      • IL-1α: 94%
      • IL-1β: 91%
      • IL-4: 93%
      • IL-6: 95%
      • IL-8: 95%
      • IL-10: 96%
      • IL-17A: 103%
      • MIP-1α: 96%
      • IL-36RA: 98%
      • IP-10: 94%
      • MCP-1: 95%
      • MIP-1β: 97%
      • TNFα: 92%
      • VEGF-A: 97%
      Physicochemical Information
      Sensitivity
      • IFNγ: 0.08 pg/mL
      • IL-1α: 0.36 pg/mL
      • IL-1β: 4.93 pg/mL
      • IL-4: 16.57 pg/mL
      • IL-6: 11.23 pg/mL
      • IL-8: 22.6 pg/mL
      • IL-10: 1.05 pg/mL
      • IL-17A: 0.67 pg/mL
      • MIP-1α: 98.54 pg/mL
      • IL-36RA: 1.23 pg/mL
      • IP-10: 0.91 pg/mL
      • MCP-1: 2.74 pg/mL
      • MIP-1β: 2.32 pg/mL
      • TNFα: 22.62 pg/mL
      • VEGF-A: 1.18 pg/mL
      Standard Curve Range
      • IFNγ: 0.1 – 2,000 pg/mL
      • IL-1α: 0.3 – 5,000 pg/mL
      • IL-1β: 2.6 – 40,000 pg/mL
      • IL-4: 12.8 – 200,000 pg/mL
      • IL-6: 2.6 – 40,000 pg/mL
      • IL-8: 2.2 – 35,000 pg/mL
      • IL-10: 0.96 – 15,000 pg/mL
      • IL-17A: 0.6 – 10,000 pg/mL
      • MIP-1α: 12.8 – 200,000 pg/mL
      • IL-36RA: 1.28 – 20,000 pg/mL
      • IP-10: 0.6 – 10,000 pg/mL
      • MCP-1: 1.92 – 30,000 pg/mL
      • MIP-1β: 2.2 – 35,000 pg/mL
      • TNFα: 12.8 – 200,000 pg/mL
      • VEGF-A: 1.28 – 20,000 pg/mL
      Dimensions
      Materials Information
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Usage Statement
      • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
      Storage and Shipping Information
      Storage ConditionsRecommended storage for kit components is 2 - 8°C.
      Packaging Information
      Material Size96-well plate
      Material Package96 well plate
      Transport Information
      Supplemental Information
      Specifications
      Global Trade Item Number
      カタログ番号 GTIN
      BCYT1-33K-PX15 04054839000263