Custom Premix Selecting "Custom Premix" option means that all of the beads you have chosen will be premixed in manufacturing before the kit is sent to you.
Catalogue Number
Ordering Description
Qty/Pack
List
この品目はお気に入りに追加されました。
動物種
パネルタイプ
選択したキット
数量
カタログ番号
注文内容
Qty/Pk
価格
96-Well Plate
数量
カタログ番号
注文内容
Qty/Pk
価格
その他の試薬を追加 (MAPmatesとともに使用するにはバッファーおよび検出キットが必要です)
数量
カタログ番号
注文内容
Qty/Pk
価格
48-602MAG
Buffer Detection Kit for Magnetic Beads
1 Kit
Space Saver Option(チェックを入れると箱詰めから袋詰めに変更となりますのでご注意ください) Customers purchasing multiple kits may choose to save storage space by eliminating the kit packaging and receiving their multiplex assay components in plastic bags for more compact storage.
1 Strongly contaminated halogen-free organic solvents: container A.
安全性情報
危険区分
引火性が高い, 刺激性
製品使用について
保管および輸送に関する情報
保管
+15°C~+25°Cで保存。
パッケージ情報
輸配送情報
輸送方法(鉄道及びトラック)ADR、RID
UN 2924 , 3 (8), II
輸送方法(航空便)IATA-DGR
UN 2924 , 3 (8), II
輸送方法(船便)IMDGコード
UN 2924 , 3 (8), II, Segregation Group: 1 (Acids)
補足情報
規格
Form
liquid
Amount-of-substance concentration
0.0993 - 0.1007 mol/l
Measurement uncertainty
+/- 0.0005
Traceability
NIST SRM
The stated batch and specification values for the amount of substance concentration are valid at the time of bottling. The amount-of-substance concentration of this volumetric solution is analyzed by our quality control laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The concentration is determined by volumetric titration and refers to 20°C. The amount-of-substance concentration of this volumetric solution is determined with standardized potassium hydroxide solution in isopropanol (article number 1.05544). The potassium hydroxide solution in isopropanol is standardized and traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 84 potassium hydrogen phthalate) by means of volumetric standard potassium hydrogen phthalate (article number 1.02400), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%. Note: The concentration of this volumetric solution decreases over time, due to its chemical properties. If high accuracy is expected, the titer, being a corrective factor that compensates for this effect as well as variations of equipment, personal handling, temperature and other laboratory conditions, must be determined directly after opening a new bottle and should be verified at regular intervals.