      概要

      Replacement Information

      主要スペック表

      SpeciesHost CellsProtein Target
      Human Chem-1glucagon / GCG
      Description
      Catalogue NumberHTS112M
      Brand Family Chemicon®
      Trade Name
      • ChemiScreen
      • Chemicon
      DescriptionChemiScreen™ Recombinant Human Glucagon Receptor Membrane Preparation
      OverviewTRANSFECTION: Full-length human GCGR cDNA encoding Glucagon Receptor
      HOST CELLS: Chem-1, an adherent mammalian cell line with no endogenous glucagon receptor expression.
      Background InformationGlucagon is a 29-amino acid peptide that stimulates glycogenolysis and gluconeogenesis in the liver to increase blood glucose. The receptor for glucagon is a class 2 (or class B) GPCR that signals through Gs to stimulate cAMP production (Mayo et al., 2003). Mice lacking the glucagon receptor have mild hypoglycemia after fasting, and exhibit hyperplasia of pancreatic α-cells (Gelling et al., 2003). Because of its role in promoting hyperglycemia, the glucagon receptor presents a potential target for treatment of diabetes. Chemicon's glucagon receptor membrane preparations are crude membrane preparations made from our proprietary stable recombinant cell lines to ensure high-level of GPCR surface expression; thus, they are ideal HTS tools for screening of antagonists of glucagon receptor interactions and its ligands. The membrane preparations exhibit a Kd of 3.09 nM for [125I]-glucagon. With 1 nM [125I]-glucagon, 5 or 10 μg/well glucagon receptor Membrane Prep yields greater than 10-fold signal-to-background ratio.
      References
      Product Information
      FormatMembranes
      PresentationLiquid in packaging buffer: 50 mM Tris pH 7.4, 10% glycerol and 1% BSA; no preservatives.
      Packaging method: Membrane proteins were adjusted to 0.5 mg/ml in 1 ml packaging buffer, rapidly frozen, and stored at -80°C.
      Quality LevelMQ100
      Applications
      ApplicationHuman glucagon / GCG GPCR membrane preparation for Radioligand binding Assays & GTPγS binding.
      Key Applications
      • Radioligand binding assay
      • GTPγS binding
      Application NotesRadioligand binding assay and GTPγS binding
      Biological Information
      Entrez Gene Number
      Entrez Gene SummaryThe physiologic effects of glucagon (GCG; MIM 138030) are mediated through the glucagon receptor, a member of the superfamily of receptors characterized by a 7-transmembrane domain structure and by their coupling via GTP-binding proteins (G proteins) to adenyl cyclase.[supplied by OMIM]
      Gene Symbol
      • GCGR
      • MGC138246
      • GL-R
      • GGR
      GPCR ClassB
      Host CellsChem-1
      Protein Targetglucagon / GCG
      Target Sub-FamilyGlucagon
      UniProt Number
      UniProt SummaryFUNCTION: SwissProt: P47871 # This is a receptor for glucagon which plays a central role in regulating the level of blood glucose by controlling the rate of hepatic glucose production and insulin secretion. The activity of this receptor is mediated by G proteins which activate adenylyl cyclase and also a phosphatidylinositol-calcium second messenger system.
      SIZE: 477 amino acids; 54009 Da
      SUBCELLULAR LOCATION: Cell membrane; Multi-pass membrane protein.
      DISEASE:SwissProt: P47871 # It is a candidate for certain defects in non-insulin- dependent diabetes mellitus (NIDDM). The variant in position 40 (Ser) is found in some NIDDM patients, but also in nondiabetic subjects.
      SIMILARITY: SwissProt: P47871 ## Belongs to the G-protein coupled receptor 2 family.
      Incubation ConditionsRECOMMENDED ASSAY CONDITIONS: Membranes are mixed with radioactive ligand and unlabeled competitor in binding buffer in a nonbinding 96-well plate, and incubated for 1-2 h. Prior to filtration, a GF/C 96-well filter plate is coated with 0.33% polyethyleneimine for 30 min, then washed with 50mM HEPES, pH 7.4, 0.5% BSA. Binding reaction is transferred to the filter plate, and washed 3 times (1 mL per well per wash) with Wash Buffer. The plate is dried and counted.
      • Binding buffer: 50 mM Hepes, pH 7.4, 5 mM MgCl2, 1 mM CaCl2, 0.2% BSA, filtered and stored at 4°C
      • Radioligand: [125I]-glucagon (Perkin Elmer#:NEX-207)
      • Wash Buffer: 50 mM Hepes, pH 7.4, 500mM NaCl , 0.1% BSA, filtered and stored at 4°C.

      One package contains enough membranes for at least 200 assays (units), where a unit is the amount of membrane that will yield greater than 10-fold signal:background with [125I]-labeled glucagon at 1 nM
      Physicochemical Information
      Dimensions
      Materials Information
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      SPECIFICATIONS:
      1 unit = 5 μg
      Bmax for [125I] glucagon binding: 16.7 pmol/mg protein
      Kd for [125I] glucagon binding: ~ 3.09 nM

      Signal:background and specific binding values obtained in a competition binding assay with varying amounts of Glucagon receptor membrane prep:
      Product Usage Statements
      10 µg/well 5 µg/well
      Signal:Background 10.1 35
      Specific Binding (cpm) 33315 36252
      Usage Statement
      • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
      Storage and Shipping Information
      Storage ConditionsMaintain frozen at -70°C for up to 2 years. Do not freeze and thaw.
      Packaging Information
      Material Size200 units
      Transport Information
      Supplemental Information
      Specifications
      Global Trade Item Number
      カタログ番号 GTIN
      HTS112M 04053252321610

      Documentation

      ChemiScreen™ Recombinant Human Glucagon Receptor Membrane Preparation (M)SDS

      タイトル

      英語版製品安全データシート((M)SDS) 

      ChemiScreen™ Recombinant Human Glucagon Receptor Membrane Preparation 試験成績書(CoA)

      タイトルロット番号
      CHEMISCREENTM MEMBRANE PREPARATION SC541032
      CHEMISCREENTM MEMBRANE PREPARATION RECOMBINANT HUMAN GLUCAGON RECEPTOR - 2116033 2116033
      CHEMISCREENTM MEMBRANE PREPARATION RECOMBINANT HUMAN GLUCAGON RECEPTOR - 2250865 2250865

      参考資料

      参考資料の概要Pub Med ID
      Lower blood glucose, hyperglucagonemia, and pancreatic alpha cell hyperplasia in glucagon receptor knockout mice.
      Gelling, R W, et al.
      Proc. Natl. Acad. Sci. U.S.A., 100: 1438-43 (2003)  2003

      概要を表示する
      12552113 12552113
      International Union of Pharmacology. XXXV. The glucagon receptor family.
      Mayo KE et al.
      Pharmacol. Rev., 55:167-194 (2003)  2003

      12615957 12615957

      データシート

      タイトル
      CHEMISCREENTM MEMBRANE PREPARATION RECOMBINANT HUMAN GLUCAGON RECEPTOR

      関連製品&アプリケーション

      製品ファミリー

      関連製品: Brand Facete

      カテゴリー

      Life Science Research > Drug Discovery and Development > GPCR Cell Lines & Assays > GPCR Membrane Preparations
      Life Science Research > タンパク質と酵素 > GPCR Membrane Preparations