Millipore Sigma Vibrant Logo

CHR100 ChIC/CUT&RUN Kit (pA-MN)

CHR100
12 reactions  
価格を検索中…
価格が見つかりません
Minimum Quantity needs to be mulitiple of
Maximum Quantity is
弊社照会 詳細を表示 
値引
()
 
弊社照会
現在国内在庫なし
現在国内在庫なし
現在国内在庫有り 
販売中止
在庫僅少
現在国内在庫あり
    Remaining : Will advise
      Remaining : Will advise
      注文対象外
      お問合せください
      Contact Customer Service

       

      お問合せください

      概要

      Replacement Information
      Description
      Catalogue NumberCHR100
      DescriptionChIC/CUT&RUN Kit (pA-MN)
      Background InformationProtein-DNA interactions are essential to almost all biological processes, such as DNA replication and repair, transcription and regulation of gene expression. Among many techniques interrogating protein-DNA interactions, chromatin immunoprecipitation (ChIP) has been the dominant method. Even though improvements have been made to its readout strategies, ChIP has many problems and inefficiencies, such as high background that limits sensitivity, high amounts of cellular input, and artifacts resulting from cross-linking and protein solubilization.

      In 2004, from the Laemmli lab, Schmid et al. reported a novel alternative to ChIP to detect binding sites of transcription factors in the genome by targeting micrococcal nuclease (MNase) conjugated with protein A (pA-MN) to specifically cleave DNA at regions interacting with a protein of interest through a specific antibody. Importantly, MNase is activated and cleaves only in the presence of Ca2+ ions, thus allowing for controlled DNA cleavage. This novel method is termed chromatin immuno-cleavage (ChIC)1. As a result, protein-DNA mapping resolution was improved to 10-200bp with excellent specificity. Furthermore, in 2018, Skene et al. in the Henikoff lab combined ChIC with sequencing to detect genome-wide transcription factor binding sites and histone modifications on native chromatin and termed Cleavage Under Targets and Release Using Nuclease (CUT&RUN)2.

      In the ChIC/CUT&RUN methods, only the targeted fragments are released into solution and the majority of DNA is left behind, leading to an exceptionally low background level. As a result, ChIC/CUT&RUN provides high-quality results using only 100 cells for a histone modification analysis and 1,000 cells for a transcription factor binding site analysis. In contrast to ChIP, ChIC/CUT&RUN is free of solubility issues and DNA accessibility artifacts from cross-linking solubilization. ChIC/CUT&RUN out-performs ChIP in resolution, signal-to-noise ratio, and depth of sequencing required.

      Based on these two publications, we developed ChIC/CUT&RUN kits to enable researchers conveniently perform ChIC/CUT&RUN experiments. The kits supply all key reagents and buffers to prepare ChIC/CUT&RUN samples before the DNA sequencing library preparation step. There are three kit configurations namely with protein A-micrococcal nuclease (pA-MN, Cat. No. CHR100), protein G-micrococcal nuclease (pG-MN, Cat. No. CHR101) and pA-MN/pG-MN fusion protein blend (Cat. No. CHR102). pA-MN has higher affinity to most antibodies including rabbit IgG, whereas pG-MN is more suitable for antibodies that have low affinity to protein A for example mouse IgG1. pA-MN/pG-MN blend allows for either choice. MilliporeSigma also supply DNA extraction kit for ChIC/CUT&RUN (12 rxns, Cat. No. CHR104), and 2% digitonin solution (Cat. No. CHR103) as accessory products for ChIC/CUT&RUN assays.

      In additiona, a ChIC and CUT&RUN data analysis tool is created to enable our customers to process and analyze the resulting data yourself. For customers who purchased our ChIC/CUT&RUN kits, they can access the data analysis tool for free by following the steps in the instruction sheet found in the ChIC/CUT&RUN kit’s package. Your order ID can be found on the packing slip, the order confirmation or retrieved by calling your local Customer Service. For more information about the data analysis tool, please view here.

      References
      1. Schmid, M., Durussel,T., Laemmli, U.K. ChIC and ChEC: genomic mapping of chromatin proteins. Molecular Cell. 16, 147-157 (2004).
      2. Skene, P. J., Henikoff J. G., Henikoff, S. Targeted in situ genome-wide profiling with high efficiency for low cell numbers. Nature Protocols. 13, 1006-1019 (2018).
      References
      Product Information
      Components
      • Concanavalin A-coated magnetic beads
        Binding Buffer
        Wash Buffer
        Spermidine
        0.5M EDTA
        Rinse Buffer
        Incubation buffer
        Stop Solution
        2% Digitonin containing DMSO
        RNase A
        Spike-in DNA
        Precipitate Enhancer
        Proteinase K Solution
        Protease Inhibitor Cocktail III, Animal Free **Contains DMSO
        Rabbit IgG Purified
        Anti-H3K27me3 rabbit monoclonal antibody
        Protein A–micrococcal nuclease (pA-MN) fusion protein
      Applications
      ApplicationA novel alternative to ChIP with a much faster procedure,extremely low signal-to-noise ratio and much less starting sample.
      Application NotesThis kit provides the following benefits for your genome-wide profiling of chromatin protein interactions.
      • Extremely low signal-to-noise ratio than cross-linking ChIP-seq (Because of the very low background with ChIC/CUT&RUN, typically 5 million paired-end reads per sample suffice for TFs or nucleosome modifications).
      • Cross-linking eliminated thus sonicators or high-speed spin steps not needed.
      • Much lower number of starting cells (minimum 100 cell for histone modification and 1,000 cells for a transcription factor).
      • Much shortened procedure time – from cells to purified DNA completed within one day (minimum 3 hours).
      • No special equipment needed, using standard equipment that is already present in most molecular biology laboratories.

      For more information, please view here.
      Biological Information
      ConcentrationPlease refer to lot specific datasheet.
      Physicochemical Information
      Dimensions
      Materials Information
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Usage Statement
      • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
      Storage and Shipping Information
      Storage ConditionsStore ChIC component box 1 at 2°C-8ºC and ChIC component box 2 at -20°C; performance guaranteed for 6 months from date of receipt when reagents are stored properly.
      Packaging Information
      Material Size12 reactions
      Transport Information
      Supplemental Information
      Specifications
      Global Trade Item Number
      カタログ番号 GTIN
      CHR100 04061841034711