Millipore Sigma Vibrant Logo

17-10506 AccuChIP™ Acetyl-Histone H3 (Lys9) Chromatin Immunoprecipitation Internal Control

View This Product on Sigma-Aldrich
17-10506
100 reactions  
価格を検索中…
価格が見つかりません
Minimum Quantity needs to be mulitiple of
Maximum Quantity is
弊社照会 詳細を表示 
値引
()
 
弊社照会
現在国内在庫なし
現在国内在庫なし
現在国内在庫有り 
販売中止
在庫僅少
現在国内在庫あり
    Remaining : Will advise
      Remaining : Will advise
      注文対象外
      お問合せください
      Contact Customer Service

       

      お問合せください

      概要

      Replacement Information

      主要スペック表

      Key Applications
      ChIP, ChIP-seq
      Description
      Catalogue Number17-10506
      Brand Family Upstate
      DescriptionAccuChIP™ Acetyl-Histone H3 (Lys9) Chromatin Immunoprecipitation Internal Control
      OverviewAccuChIP™ Chromatin Immunoprecipitation Internal Controls are designed to improve the accuracy of ChIP experiments. This simple to spike-in reagent is composed of a target-specific peptide sequence covalently bound to a uniquely designed double stranded nucleic acid sequence. Because AccuChIP controls mimic the behavior of cross-linked chromatin, by simply adding a known amount of the AccuChIP reagent to your chromatin and performing a standard ChIP reaction followed qPCR detection you can improve the accuracy and reproducibility of your ChIP experiments.

      Features and Advantages
      • Simple to use - just add to chromatin either before or after sonication
      • Mimics the behavior of cross-linked chromatin to allow normalization of ChIP signals
      • Target specific control - uses the same antibody used for your ChIP experiment
      • Reduces ChIP variation due to variables such as chromatin preparation, antibody affinity, inconsistent background signals from carry over, and loss of material during handling
      • Easily incorporated into virtually any ChIP protocol
      • Readily detected by qPCR
      • Easily incorporated into ChIP-seq libraries
      • Variety of uniquely designed controls available -add multiple controls to be added to the same chromatin as an process antibody specificity
      Materials Required but Not Delivered
      • Reagents and materials for chromatin isolation from cells or tissues (e.g PureEpi Chromatin Preparation and Optimization kit; EMD Millipore Cat# 17-10082)
      • Sonication device or method to shear chromatin
      • Beads, reagents and buffers to perform chromatin immunoprecipitation (e.g. Magna ChIP HiSens Chromatin Immunoprecipitation Kit EMD Millipore Cat# 17-10460, or EZ-Magna ChIP HiSens Chromatin Immunoprecipitation Kit Cat# 17-10461)
      • ChIP validated antibody or ChIPAb+™ kit
      • IgG negative control antibody (visit www.emdmillipore.com/antibodies to order the IgG negative control antibody used with this control)
      • Real time thermal cycler and qPCR reagents and primers for locus of interest
      • Reagents and instrument for next generation sequencing analysis (optional)
      References
      Product Information
      Components
      • AccuChIP™ H3K9Ac Spike-In Reagent (50 pg/uL )
      • AccuChIP™ H3K9Ac Detection Primer Mix (5 μM)
      • AccuChIP™ Dilution Buffer
      PresentationOne box containing three vials (one vial each of target specific AccuChIP™ Spike-In Reagent, target specific AccuChIP™ Detection Primer Mix, and AccuChIP™ Dilution Buffer)
      Quality LevelMQ100
      Applications
      ApplicationTarget-specific spike-in controls that make ChIP experiments more quantitative and accurate. Applications include:
      • Normalization of ChIP signals
      • Normalization of ChIP-seq signals
      • Analysis of antibody specificity
      Key Applications
      • Chromatin Immunoprecipitation (ChIP)
      • ChIP-seq
      Biological Information
      Physicochemical Information
      Dimensions
      Materials Information
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Usage Statement
      • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
      Storage and Shipping Information
      Storage ConditionsAccuChIP™ Chromatin Immunoprecipitation Internal Controls are stable for 6 months at -20 ºC from date of receipt.
      AccuChIP Spike In Reagent is provided as a 20X stock and should be diluted with the provided AccuChIP™ Dilution Buffer to create a working stock. Diluted AccuChIP Spike In Reagent can be stored in aliquots at -20 ºC for up to 3 months. AccuChIP Spike In reagent is composed of a peptide-double stranded DNA conjugate in a buffer containing BSA and glycerol to reduce adherence to the tube. The use of siliconized microfuge tubes for storage of diluted material is recommended.
      Packaging Information
      Material Size100 reactions
      Transport Information
      Supplemental Information
      Specifications
      Global Trade Item Number
      カタログ番号 GTIN
      17-10506 04055977121704

      Documentation

      AccuChIP™ Acetyl-Histone H3 (Lys9) Chromatin Immunoprecipitation Internal Control (M)SDS

      タイトル

      英語版製品安全データシート((M)SDS) 

      AccuChIP™ Acetyl-Histone H3 (Lys9) Chromatin Immunoprecipitation Internal Control 試験成績書(CoA)

      タイトルロット番号
      AccuChIP™ Acetyl-Histone H3 (Lys9) Chromatin Immunoprecipitation Internal Control - Q2495402 Q2495402

      Posters

      タイトル
      The use of a synthetic histonepeptide-DNA conjugates as a spike-in reagent to normalize chromatin immunoprecipitation experiments