Custom Premix Selecting "Custom Premix" option means that all of the beads you have chosen will be premixed in manufacturing before the kit is sent to you.
Catalogue Number
Ordering Description
Qty/Pack
List
この品目はお気に入りに追加されました。
動物種
パネルタイプ
選択したキット
数量
カタログ番号
注文内容
Qty/Pk
価格
96-Well Plate
数量
カタログ番号
注文内容
Qty/Pk
価格
その他の試薬を追加 (MAPmatesとともに使用するにはバッファーおよび検出キットが必要です)
数量
カタログ番号
注文内容
Qty/Pk
価格
48-602MAG
Buffer Detection Kit for Magnetic Beads
1 Kit
Space Saver Option(チェックを入れると箱詰めから袋詰めに変更となりますのでご注意ください) Customers purchasing multiple kits may choose to save storage space by eliminating the kit packaging and receiving their multiplex assay components in plastic bags for more compact storage.
Following stimulation, cells are removed, wells extensively washed, and a second analyte-specific Ab is applied. At this and all subsequent steps, washing is critical for the complete removal of cells, nonspecifically bound Ab, and detection reagent. Incomplete removal of unbound reagents will lead to an overall increase in background signal (see troubleshooting chart).
Detection - Chromogenic vs. Fluorescent Options
ELISpot assays may be performed either with antibodies directly conjugated to the detection motif (enzyme or fluorochrome) or as a two-step process involving a biotin/streptavidin-conjugated Ab pair.
While the two-step process offers greater intensity due to signal amplification, and therefore may be preferable in cases where cytokine production per cell is low (allergy/Th2 responses), this protocol could create a greater potential for background staining due to nonspecific interaction with the coating Ab. With enzymes, such as horseradish peroxidase (HRP), a precipitating substrate (TMB or AEC) is used for spot detection. Due to HRP’s high turnover rate, spot development is fast (≤5 minutes).
By contrast, spot development using alkaline phosphatase-conjugated Abs is far slower but with appreciably lower background. For chromogenic assays performed on MultiScreen®HTS plates (those with underdrains), it is recommended that the underdrain be removed prior to substrate addition; failure to do so can result in high background staining. Once removed, plates should be propped up to minimize membrane contact. To enhance spot visualization, plates should be dried without a lid, upside down, at room temperature for several hours. For long-term storage, plates should be kept in a dark, dry place at room temperature to prevent bleaching of spots.
As previously discussed, the use of fluorescent conjugates offers significant advantages over colorimetric schemes especially for dual cytokine applications or where greater quantitative assessments of individual spots is desired. While FITC- and Cy3-conjugated Abs are commonly used, the choice of fluorescent probe is limited only by the availability of conjugates and detection platforms.