Millipore Sigma Vibrant Logo

SCGP00525 Steriflip-GP Sterile Centrifuge Tube Top Filter Unit

View This Product on Sigma-Aldrich
SCGP00525
25  
Retrieving price...
Price could not be retrieved
Minimum Quantity is a multiple of
Maximum Quantity is
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Limited Availability
Limited Availability
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

       

      Contact Customer Service

      Overview

      Replacement Information

      Key Spec Table

      SterilityProcess VolumePore Size
      Sterile50 mL0.22 µm
      Description
      Catalogue NumberSCGP00525
      Trade Name
      • Steriflip
      DescriptionSteriflip-GP Sterile Centrifuge Tube Top Filter Unit
      Background InformationThe Steriflip filter unit is designed to work with standard 50 mL centrifuge tubes, which eliminates sample transfer. To filter, just attach the unit to a 50 mL centrifuge tube containing your sample, flip it over, and apply the vacuum. When finished, the filtrate collects in the attached 50 mL centrifuge tube.

      New pore sizes ideal for Cell Isolation applications

      Steriflip Nylon Net filters are now available in 40, 60 and 100 µm pore sizes, making them ideal for stem cell, cardiomyocite, neurological and skeletal tissue applications. The vacuum-assisted, closed system option ensures sample sterility while enabling faster separation of large volumes of cellular material and improved recoveries.

      The Steriflip® filter unit eliminates messy pouring during sample transfer. Directly attach the unit to a 50 mL centrifuge tube containing your sample, flip it over, and apply vacuum. The filtrate collects in the attached 50 mL centrifuge tube. Steriflip® filters come in different pore sizes that are ideal for cell isolation. These include nylon net filters in 40, 60 and 100 µm pore sizes, which are ideal for stem cell, cardiomyocyte, neurological and skeletal tissue applications. The vacuum-assisted, closed system ensures sample sterility while enabling fast separation of large volumes of cellular material for efficient recoveries.

      Features & Benefits:
      Eliminates messy sample transfer via a simple vacuum-assisted, closed system
      Isolate cells from cellular debris using any of the various pore-sized nylon net filters
      Ideal for sterilizing small batches of culture media
      Attaches to any standard 50 mL centrifuge tube, eliminating unnecesary materials, time and risk of spillage
      Applications:
      Sterilization of Aqueous Solutions (up to 50 mL), Sterile Filtration of Small Batches of Culture Media, Sterile Filtration of Buffers with High Value Protein or Small Molecule Components, Cell Isolation
      References
      Product Information
      Fitting InletDouble lead thread with vacuum port
      Fitting OutletDouble lead thread for 50 mL centrifuge tube
      Color CodeClear
      Maximum Operating Temperature45 °C
      Receiver50 mL centrifuge tube with cap
      Quality LevelMQ400
      Applications
      ApplicationSterile, 50 mL process volume, 0.22 µm pore size, polyethersulfone membrane, sterilized by gamma irradiation
      Key Applications
      • Sterile Filtration
      Biological Information
      MediaExpress PLUS®
      SterilitySterile
      SterilizationGamma irradiation
      WettabilityHydrophilic
      Physicochemical Information
      Pore Size0.22 µm
      Pressure/VacuumVacuum
      Hold-up Volume0.6 mL
      Dimensions
      Height138 mm
      Diameter6.4 cm
      Filtration Area7 cm²
      Funnel Capacity50 mL
      Process Volume50 mL
      Volume50 mL
      Filter Diameter (⌀)40 mm
      Nominal Pore Size0.22 µm
      Materials Information
      Chemistry
      • Polyethersulfone (PES)
      Device Material
      • MBS/Polypropylene
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Usage Statement
      • For research use only.
      Storage and Shipping Information
      Packaging Information
      Material Size25
      Transport Information
      Supplemental Information
      Specifications
      Global Trade Item Number
      Catalogue Number GTIN
      SCGP00525 08436037126123

      Documentation

      Certificates of Quality

      Title
      Certificate of Quality SCGP00525-MPSF215101
      Certificate of Quality SCGP00525-MPSF221203
      Certificate of Quality SCGP00525-MPSF221206
      Certificate of Quality SCGP00525-MPSF221302
      Certificate of Quality SCGP00525-MPSF221306
      Certificate of Quality SCGP00525-MPSF221311
      Certificate of Quality SCGP00525-MPSF221408
      Certificate of Quality SCGP00525-MPSF222204
      Certificate of Quality SCGP00525-MPSF222303
      Certificate of Quality SCGP00525-MPSF222307

      Brochure

      Title
      Simply better membrane technology, simply better Stericup®filters.
      Sterile Filtration You Trust

      User Guides

      Title
      User Guide - Steriflip® Filter