Millipore Sigma Vibrant Logo
Attenzione: Ci siamo trasferiti. Non è più possibile acquistare i prodotti Merck Millipore nel sito MerckMillipore.comPer saperne di più

2160 Autofluorescence Eliminator Reagent

2160
50 mL  
Purchase on Sigma-Aldrich

Panoramica

Replacement Information

Tabella delle specifiche principali

Key Applications
IHC
Description
Catalogue Number2160
Brand Family Chemicon®
Trade Name
  • Chemicon
DescriptionAutofluorescence Eliminator Reagent
OverviewReady-to-use for application in fluorescence microscopy procedures. With increasing age, the autofluorescent pigment lipofuscin accumulates in the cytoplasm of many cell types, including neurons. The presence of lipofuscin granules can complicate the use of fluorescence microscopy in the central nervous system because of its broad excitation and emission spectra, which overlaps with those of most commonly used fluorophores. The Autofluorescence Eliminator Reagent will reduce or eliminate lipofuscin-like autofluorescence without adversely affecting other fluorescent label in sections of human, monkey or rat neural tissue as well as other tissues.
References
Product Information
PresentationLiquid in 70% ethanol containing no preservatives. Store at room temperature in the dark.
Applications
ApplicationAutofluorescence Eliminator Reagent for IHC.
Key Applications
  • Immunohistochemistry
Application NotesFluorescence immunohistochemistry counterstain.

PROTOCOL:

1.After immunofluorescence histochemistry, the sections are immersed in PBS for 5 min.·

2.Sections are immersed in 70% ethanol for 5 min.·

3.Sections are immersed in Autofluorescence Eliminator Reagent for 5 min.

4.Sections are immersed in three changes of 70% ethanol for 1 min. each time.·

5.Sections are mounted using an antifading solution (e.g. DABCO, non-xylene-based).



Note: Reagent will block all fluorescence if incubation is too long; length of incubation time and number of 70% ethanol washes can be altered and optimized for various tissues and fluorescent antibody probes. In some instances the reagent can be applied prior to immunofluorescence, however in most cases better results are obtained when used as we direct above (use after immunofluorescence procedures are completed).



Optimal time of incubation with the Autofluorescence Eliminator Reagent should be determined by the end user for each sample.

Absorption maximum: 595-605
Biological Information
Physicochemical Information
Dimensions
Volume50 mL
Materials Information
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Usage Statement
  • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Storage and Shipping Information
Storage ConditionsWhen stored at room temperature, this reagent is stable up to the expiration date printed on the label. Do not freeze or expose to elevated temperatures.
Packaging Information
Material Size50 mL
Transport Information
Supplemental Information
Specifications
Global Trade Item Number
Numero di catalogo GTIN
2160 04053252323584

Documentation

Autofluorescence Eliminator Reagent MSDS

Titolo

Scheda di sicurezza (MSDS) 

Autofluorescence Eliminator Reagent Certificati d'Analisi

TitoloNumero di lotto
AUTOFLUORESCENCE ELIMINATOR REAGENT 2952686
AUTOFLUORESCENCE ELIMINATOR REAGENT 3016635
AUTOFLUORESCENCE ELIMINATOR REAGENT 2987603
AUTOFLUORESCENCE ELIMINATOR REAGENT 3147602
AUTOFLUORESCENCE ELIMINATOR REAGENT 3156770
AUTOFLUORESCENCE ELIMINATOR REAGENT 2840415
AUTOFLUORESCENCE ELIMINATOR REAGENT 3040796
AUTOFLUORESCENCE ELIMINATOR REAGENT 2861905
AUTOFLUORESCENCE ELIMINATOR REAGENT 2905302
AUTOFLUORESCENCE ELIMINATOR REAGENT 2899739

Riferimenti bibliografici

Panoramica dei riferimenti bibliograficiCodice d'identificazione nel Pub Med
Deletion of the huntingtin proline-rich region does not significantly affect normal huntingtin function in mice.
Neveklovska, M; Clabough, EB; Steffan, JS; Zeitlin, SO
Journal of Huntington's disease  1  71-87  2011

Mostra il sommario
22956985 22956985

Scheda tecnica

Titolo
AUTOFLUORESCENCE ELIMINATOR REAGENT