UFC910008 MilliporeUltrafiltri centrifughi Amicon Ultra-15 con membrana Ultracel-PL PLHK, 100 kDa
Ultracel-100 regenerated cellulose membrane, 15 mL sample volume
More>> Ultracel-100 regenerated cellulose membrane, 15 mL sample volume Less<<Prodotti consigliati
Panoramica
Replacement Information |
---|
Tabella delle specifiche principali
Key Applications | NMWL | Volume | Volume minimo del concentrato finale |
---|---|---|---|
Estrazione delle proteine, Purificazione delle proteine | 100 KDa | 15 mL | 200 µL |
Riferimenti bibliografici |
---|
Informazioni sul prodotto | |
---|---|
Codice del filtro | PLHK |
Codice colore | Transparente con tappo rosa |
Tipo di filtro | Ultrafiltrazione |
NMWL | 100 KDa |
Quality Level | MQ400 |
Informazioni biologiche | |
---|---|
Sterilità | Non sterile |
Informazioni chimico-fisiche | |
---|---|
Applicazioni centrifughe | Protein Concentration and Desalting |
Dimensioni | |
---|---|
Lunghezza | 12.1 cm (4.807 in.) |
Diametro | 2.97 cm |
Superficie filtrante | 7.6 cm² |
Volume minimo del concentrato finale | 200 µL |
Volume | 15 mL |
Informazioni tossicologiche |
---|
Informazioni sulla sicurezza secondo il GHS |
---|
Informazioni per la sicurezza |
---|
Indicazioni sull'impiego del prodotto |
---|
Informazioni per lo stoccaggio e la spedizione |
---|
Informazioni sul confezionamento | |
---|---|
Quantità | 8 |
Informazioni per il trasporto |
---|
Informazioni supplementari |
---|
Specifiche |
---|
Global Trade Item Number | |
---|---|
Numero di catalogo | GTIN |
UFC910008 | 04053252504129 |
Documentation
Brochure
Titolo |
---|
REFINE PROTEIN PREPARATION. Tools for better protein analysis |
FAQ
Domanda | Risposta | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Amicon Ultra units are offered in what volumes? | Amicon Ultra units are available in 0.5 mL, 4mL & 15ml volumes. | ||||||||||||
What is the recommended rotor for Amicon Ultra units? | Any rotor capable of accommodating 22.7 cm in diameter and 124 mm length centrifuge tubes for the Amicon Ultra-4 and 35 mm in diameter and 121 mm in length for the Amicon Ultra-15 can be used for Amicon Ultra units. | ||||||||||||
How should I select the appropriate Molecular Weight Cutoff (MWCO) for Amicon Ultra? | Select a Molecular Weight Cutoff that is 2x smaller that the Molecular Weight (MW) of the solute of interest. | ||||||||||||
Which membranes are available in Amicon Ultra units? | Amicon Ultra units are only available with Ultracel regenerated cellulose material. This high recovery/low binding membrane is offered in 3,000, 10,000, 30,000, 50,000 & 100,000 MWCO. | ||||||||||||
Can the Amicon Ultra be spun to dryness? | No, the Amicon Ultra has a built in deadstop. | ||||||||||||
Can the Amicon Ultra be used with nucleic acids? | Yes, Amicon Ultra units have been evaluated for use with Genomic and PCR fragments. The 30 kDa MWCO provides the best balance between recovery and spin time. Protocols related to Genomic and PCR fragments can be found in the user guide. | ||||||||||||
What is the maximum sample volume for Amicon Ultra? |
|
||||||||||||
What is the maximum centrifugal force I can spin Amicon Ultra-4 & Amicon Ultra-15? |
|
||||||||||||
What is the chemical compatibility of Amicon Ultra? | Amicon Ultra units are intended for use with biological fluids and aqueous solutions. Please refer to the user guide, catalogue, or contact Technical Support. | ||||||||||||
Can Amicon Ultra units be sterilized with ethanol? | Amicon Ultra is compatible with 70% Ethanol, but we have not done any studies to test for sterilization. |
Manuali d'uso
Titolo |
---|
Amicon® Ultra-15 Centrifugal Filter Devices Non IVD User guide |