Millipore Sigma Vibrant Logo

Pellicon® XL 50 Ultrafiltration Cassettes

True linear scalability with UF membranes with the same flow path and channel height as larger Pellicon® 2 cassettes. The Pellicon XL 50 allows process development and scaling studies.

Aperçu

Caractéristiques

Guide d'achat

Go
Biomax (Polyéthersulfone)Supprimer le tri & les filtres Show Filter
RéférenceCode du filtrePMNL
PXB005A50Biomax 5 5 kDa Prix & Disponibilité
PXB008A50Biomax 8 8 kDa Prix & Disponibilité
PXB010A50Biomax 10 10 kDa Prix & Disponibilité
PXB030A50Biomax 30 30 kDa Prix & Disponibilité
PXB050A50Biomax 50 50 kDa Prix & Disponibilité
PXB100C50Biomax 100 100 kDa Prix & Disponibilité
PXB300C50Biomax 300 300 kDa Prix & Disponibilité
PXB500C50Biomax 500 500 kDa Prix & Disponibilité
PXB01MC50Biomax 1000 1000 kDa Prix & Disponibilité

Retourner en haut de la page

Ultracel (Cellulose régénérée)Supprimer le tri & les filtres Show Filter
RéférenceCode du filtrePMNL
PXC005C50PLCCC 5 kDa Prix & Disponibilité
PXC010C50PLCGC 10 kDa Prix & Disponibilité
PXC030C50PLCTK 30 kDa Prix & Disponibilité
PXC300C50PLCMK 300 kDa Prix & Disponibilité
PXC01MC50PLCXK 1000 kDa Prix & Disponibilité
PXC100C50PLCHK 100 kDa Prix & Disponibilité

Retourner en haut de la page

AccessoiresSupprimer le tri & les filtres Show Filter
RéférenceDescription
XXPXLFTKTRaccords et tuyau Prix & Disponibilité
XXPXLSTNDSupport Pellicon XL Prix & Disponibilité
XX42RES01Réservoir, 500 ml pour système Labscale Prix & Disponibilité
XXPXLGAGEManomètre 0 – 4 bar et raccords Prix & Disponibilité

Les modules Pellicon XL sont conditionnés à raison d'un module par boîte.

Retourner en haut de la page

Documentation

Références bibliographiques

Aperçu de la référence bibliographique
Scaling Up with Tangenital Flow Filtration
Campbell, Melissa; Coons, Elizabeth
GEN; v. 21, no. 16; Sept. 15, 2001, p. 60  2001

Linear Scale Ultrafiltration
van Reis, Robert, Elizabeth M. Goodrich, Christine L. Yson, Leah N. Frautschy, Stephen Dzengeleski, and Herb Lutz
Biotechnology & Bioengineering (September 1997): 737-746.  1997

Clean-Water Permeability as a Determinant of Cleaning Efficacy in Tangential-Flow Filtration Systems
Michaels, Stephen L.; RP016
RP016  1993

Validation of Tangential Flow Filtration (TFF) Systems
Michaels, Stephen L.
Journal of Parenteral Science and Technology (Sept/Oct 1991).  1991

FAQ

QuestionRéponse
What is the sample volume range for the Pellicon II Mini system?The Pellicon II Mini system is capable of volumes in the approximate range of 1- 50 L concentrating down to 100 mL. More or less volume can be processed depending on the individual needs of the operation, ie. process time, sensitivity of product, etc.
What is the part number for the Gauge Kit that is used with the Pellicon XL?Gauge Kit for Pellicon XL Device (0-60 psi):
Part number XXPXLGAGE, 1 per kit. Includes an inlet pressure gauge and t-fitting. This gauge is recommended when the Pellicon is used in the absence of a Labscale TFF system in order to ensure that the pressure on the tubing is known and not allowed to exceed it's recommended maximum.
Can I use TFF systems to separate two proteins based on a significant difference in their respective molecular weights?As a general rule ultrafiltration does not provide high efficiency separations of protein mixtures. However, it may be possible to effect this type of separation between two proteins that have at least 10 X difference in molecular weight and if there is an ultrafiltration membrane available with a NMWL rating between the molecular weight of the two proteins. These separations are also generally more successful with dilute protein solutions and if run at low pressure.

Produits & Applications associés

Familles de produits

Produits associés classés par : Application Facete

Produits associés classés par : Brand Facete

Catégories

Biopharmaceutical Manufacturing > Downstream Processing > Ultrafiltration