Millipore Sigma Vibrant Logo

KPHLG3THH1 Opticap® Gamma Compatible XLT30 Durapore® 0.45 µm HB/HB without gauge port

View Products on Sigmaaldrich.com
KPHLG3THH1
1  
Recuperando precio...
No pudo obtenerse el precio
La cantidad mínima tiene que ser múltiplo de
Maximum Quantity is
Al finalizar el pedido Más información
Ahorró ()
 
Solicitar precio
Disponibilidad a confirmar
Disponibilidad a confirmar
Ingrese cantidad 
Suspendido
Cantidades limitadas disponibles
Debe confirmarse disponibilidad
    El resto: se avisará
      El resto: se avisará
      Se avisará
      Póngase en contacto con el Servicio de Atención al Cliente
      Contact Customer Service

       

      Póngase en contacto con el Servicio de Atención al Cliente

      Descripción

      Replacement Information
      Description
      Catalogue NumberKPHLG3THH1
      Trade Name
      • Opticap®
      DescriptionOpticap® Gamma Compatible XLT30 Durapore® 0.45 µm HB/HB without gauge port
      References
      Product Information
      Device ConfigurationCapsule
      Connections, Inlet/Outlet16 mm (5/8 in.) Hose Barb Inlet and Oulet
      Connections, Vent/Drain1/4 in. Hose Barb with double O-ring Seal
      Housing MaterialPolypropylene (PP)
      Maximum Differential Pressure, bar (psid)Forward: 4.1 bar (60 psid) @25 ˚C. Reverse: 2.1 bar (30 psid) @ 4-40 °C
      Maximum Inlet Pressure, bar (psi)5.5 bar (80 psi) @ 23 °C; 2.8 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      T-line/Gauge PortT-line
      Quality LevelMQ400
      Applications
      Application

      • Prefiltration / Bioburden reduction in single use assemblies
      • Bioburden reduction before final sterilization
      • Process protection of intermediate consumables esp. in Plasma / Vaccine / r-Protein
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaDurapore®
      SterilityNon-sterile, Gamma compatible
      SterilizationGamma compatible to 40 kGy. 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
      WettabilityHydrophilic
      Physicochemical Information
      Pore Size0.45 µm
      Inlet ConnectionHose Barb
      Outlet ConnectionHose Barb
      Air Diffusion at 23 °C≤45 mL/min @ 3.9 bar (56 psig) in water
      Bubble Point at 23 °C≥1930 mbar (28 psig) air with water
      Gravimetric ExtractablesThe extractables level was equal to or less than 25 mg per capsule after 24 hours in water at controlled room temperature.
      Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
      Maximum Inlet Pressure (psig)80 psig
      Maximum Inlet Temperature25 °C
      Non-Fiber ReleasingThis product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Cartridge Nominal Length34.3 in. (87.1 cm)
      Length87.1 cm (34.3 in.)
      Diameter10.7 cm (4.2 in.)
      Filtration Area1.86 m²
      Inlet to Outlet Width87.1 cm (34.3 in.)
      Device Size30 in.
      Inlet Connection Diameter5/8 in.
      Outlet Connection Diameter5/8 in.
      Materials Information
      Chemistry
      • Polyvinylidene Fluoride (PVDF)
      Device Material
      • Polypropylene
      Seal MaterialLead O-ring: Silicone-coated EPDM, Outer O-ring: Silicone
      Support MaterialPolyester/Polyethylene
      Vent Cap MaterialPolypropylene (PP)
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size1
      Transport Information
      Supplemental Information
      Specifications
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥4500 mL
      Global Trade Item Number
      Número de referencia GTIN
      KPHLG3THH1 04055977275759

      Documentation

      Material Qualification Dossier

      CargoVersión
      2.0

      Certificados de calidad

      Cargo
      Opticap XLT 30 Capsule Durapore Membrane C8JA87873
      Opticap XLT 30 Capsule Durapore Membrane - C0DB33372
      Opticap XLT 30 Capsule Durapore Membrane C1SB82694
      Opticap XLT 30 Capsule Durapore Membrane C3CB93226
      Opticap XLT 30 Capsule Durapore Membrane C8SA22880
      Opticap XLT 30 Capsule Durapore Membrane- C9EA38599
      Opticap XLT 30 Capsule Durapore membrane C3BB79041

      Licencias necesarias e Información técnica

      Cargo
      Autoclaving Guidelines for Opticap® XL and XLT Disposable Capsule Filters

      Ficha técnica

      Cargo
      Durapore® Family Guide

      Productos y aplicaciones relacionados

      Familias de productos

      Productos relacionados por: Brand Facete

      Categorías

      Small Molecule Pharmaceuticals > Purification of Pharm Drugs > Sterile Filtration > Sterile Liquid > Durapore
      Biopharmaceutical Manufacturing > Upstream Processing > Multi-use Processing Systems > NovAseptic > Durapore
      Small Molecule Pharmaceuticals > Purification of Pharm Drugs > Sterile Filtration > Sterile Liquid > Durapore > GAMMA Durapore XLT