Millipore Sigma Vibrant Logo

KHGEG2FHH1 Opticap® Gamma Compatible XLT 20 Millipore Express® SHC 0.5/0.2 µmum HH/HH 1pk w/3/4" TC top

View Products on Sigmaaldrich.com
KHGEG2FHH1
1  Double Easy-Open bag
Recuperando precio...
No pudo obtenerse el precio
La cantidad mínima tiene que ser múltiplo de
Maximum Quantity is
Al finalizar el pedido Más información
Ahorró ()
 
Solicitar precio
Disponibilidad a confirmar
Disponibilidad a confirmar
Ingrese cantidad 
Suspendido
Cantidades limitadas disponibles
Debe confirmarse disponibilidad
    El resto: se avisará
      El resto: se avisará
      Se avisará
      Póngase en contacto con el Servicio de Atención al Cliente
      Contact Customer Service

       

      Póngase en contacto con el Servicio de Atención al Cliente

      Descripción

      Replacement Information
      Description
      Catalogue NumberKHGEG2FHH1
      Trade Name
      • Millipore Express®
      DescriptionOpticap® Gamma Compatible XLT 20 Millipore Express® SHC 0.5/0.2 µmum HH/HH 1pk w/3/4" TC top
      References
      Product Information
      Device ConfigurationCapsule
      Connections, Inlet/Outlet16 mm (5/8 in.) Hose Barb
      Connections, Vent/Drain1/4 in. Hose Barb with double O-ring Seal; 3/4 in. Gauge Port
      Housing MaterialPolypropylene (PP)
      Maximum Inlet Pressure, bar (psi)6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
      European Pressure Equipment DirectiveEMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      T-line/Gauge PortT-line with 3/4 in. Gauge Port
      Quality LevelMQ400
      Applications
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaMillipore Express® SHC
      SterilityNon-sterile, Gamma compatible
      Sterilization3 autoclave cycles of 60 min @ 126 °C; capable of 45 kilogray (4.5 Megarad) gamma exposure; not in-line steam sterilizable
      Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
      WettabilityHydrophilic
      Physicochemical Information
      Pore Size0.5 / 0.2 µm
      Inlet ConnectionHose Barb
      Outlet ConnectionHose Barb
      Bubble Point at 23 °C≥4000 mbar (58 psig) air with water
      Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
      Maximum Inlet Pressure (psig)80 psig
      Maximum Differential PressureForward: 5500 mbar (80 psi) @ 25 °C; 1000 bar (15 psi) @ 80 °C; 6900 mbar (100 psi) @ 25 °C, intermittent. Reverse: 2100 bar (30 psi) @ 25 °C, intermittent
      Maximum Inlet Temperature25 °C
      Non-Fiber ReleasingThis product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      TOC/ConductivityAfter sterilization and a controlled water flush of 42 L, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 µS/cm per USP <645> at 25 °C.
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Cartridge Nominal Length20 in. (50 cm)
      Length62.5 cm (24.6 in.)
      Diameter19.8 cm (7.8 in.)
      Filtration Area1.09 m²
      Device Size20 in.
      Inlet Connection Diameter5/8 in.
      Outlet Connection Diameter5/8 in.
      Materials Information
      Chemistry
      • Polyethersulfone (PES)
      Device Material
      • Polypropylene/Polysulfone
      Seal MaterialSilicone (SI)
      Support MaterialPolyester
      Vent Cap MaterialPolypropylene (PP)
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size1
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Specifications
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥4 L
      Global Trade Item Number
      Número de referencia GTIN
      KHGEG2FHH1 04053252563348

      Documentation

      Material Qualification Dossier

      CargoVersión
      1.0

      Quality Management Dossier (Open Access)

      Title

      Operational Excellence Dossier

      Title

      Certificados de calidad

      Cargo
      OPTICAP XLT 20 Capsule Millipore Express SHC membrane C3DB07985
      Opticap XLT 20 Capsule Express SHC Membrane C1CB88045
      Opticap XLT 20 Capsule Milliopore Express SHC Membrane C7CA74285
      Opticap XLT 20 Capsule Millipore Express SHC Membrane
      Opticap XLT 20 Capsule Millipore Express SHC Membrane C1AB92712
      Opticap XLT 20 Capsule Millipore Express SHC Membrane C2AB10769
      Opticap XLT 20 Capsule Millipore Express SHC Membrane C8HA67358
      Opticap XLT 20 Capsule Millipore Express SHC Membrane C9PA10076
      Opticap XLT 20 Capsule Millipore Express SHC Membrane - C0AB83942
      Opticap XLT 20 Capsule Millipore Express SHC Membrane - C9MA76707

      Manuales del usuario

      Cargo
      Opticap® XL Capsules and Opticap® XLT Capsules
      Vmax Constant Pressure